Influence of Intermittent Operation on Soil Temperature and Energy Storage Duration of Ground-Source Heat Pump System for Residential Building

Author(s):  
Tao Yu ◽  
Zhimei Liu ◽  
Guangming Chu ◽  
Yunxia Qu
2013 ◽  
Vol 732-733 ◽  
pp. 564-570 ◽  
Author(s):  
Ying Ning Hu ◽  
Ya Zhao Liu ◽  
Jun Lin ◽  
Yan Wang

A ground source heat pump system of combined office and residential buildings in hot summer and warm winter region is introduced. The system performance is studied through the experiment, and the performance of underground heat balance is analyzed by TRNSYS. The results show the superiority and applicability of the ground source heat pump system.


2020 ◽  
Vol 2020 ◽  
pp. 1-18 ◽  
Author(s):  
Yan Gao ◽  
Zhi Sun ◽  
Xinxing Lin ◽  
Chuang Wang ◽  
Zongyu Sun ◽  
...  

The cold accumulation problem can lead to performance degradation of heat pumps. This paper presents the design and optimization of a solar-assisted storage system to solve this issue. A ground source heat pump (GSHP) project was established using the transient system simulation program (TRNSYS) based on a ground heat exchange theoretical model, which was validated by a previously established experiment in Beijing. The Beijing, Harbin, and Zhengzhou regions were used in numerical simulations to represent three typical cities where buildings require space heating (a cold region, a severe cold region, and a hot summer and cold winter region, respectively). System performance was simulated over periods of ten years. The simulation results showed that the imbalance efficiencies in the Beijing, Harbin, and Zhengzhou regions are 55%, 79%, and 38%, respectively. The annual average soil temperature decreases 7.3°C, 11.0°C, and 5.3°C during ten years of conventional GSHP operation in the Beijing, Harbin, and Zhengzhou regions, respectively. Because of the soil temperature decrease, the minimum heating coefficient of performance (COP) values decrease by 23%, 46%, and 11% over the ten years for GSHP operation in these three regions, respectively. Moreover, the simulation data show that the soil temperature would still be decreasing if based on the previous solar energy area calculation method. Design parameters such as the solar collector size are optimized for the building load and average soil temperature in various cold regions. Long-term operation will test the matching rate of the compensation system with the conventional GSHP system. After the system is optimized, the solar collector area increases of 20% in the Beijing region, 25% in the Harbin region, and 15% in the Zhengzhou region could help to maintain the annual average soil temperature balance. The optimized system could maintain a higher annual average COP because of the steady soil temperature. It provides a method for the design of a solar collector area which needs to be determined in the seasonal heat storage solar ground source heat pump system.


2020 ◽  
Vol 182 ◽  
pp. 03004
Author(s):  
Jintian Li ◽  
Yunzhe Ji ◽  
Bo Wang ◽  
Ling Xie

The load properties of underground engineering have an important influence on operating characteristics of ground source heat pump system. It has important reference value for design and operation management that Simulation analyzing operating conditions of ground source heat pump system under dynamic load conditions. It took an underground engineering as an example for dynamic load calculation in the paper, and simulated operating characteristics of ground source heat pump system under three operating conditions. The calculation results show that the engineering maintenance and management period is conducive to the recovery of soil temperature, and it improves the COP value of the unit. Some measures should be taken to restore soil temperature for long-term continuous operation of underground engineering. The use of heat recovery to make domestic hot water can relieve the problem of soil thermal imbalance to some extent. It is beneficial to improve heat pump unit performance.


Author(s):  
Jiang Zhu ◽  
Yong Tao

The U-tube sizes and varied thermal conductivity with different grout materials are studied based on the benchmark residential building in Hot-humid Pensacola, Florida. In this study, the benchmark building is metered and the data is used to validate the simulation model. And a list of comparative simulation cases with varied parameter value are simulated to study the importance of pipe size and grout to the ground source heat pump energy consumption. The simulation software TRNSYS [1] is employed to fulfill this task. The results show the preliminary energy saving based on varied parameters. Future work needs to be conducted for the cost analysis, include the installation cost from contractor and materials cost.


2018 ◽  
Vol 37 (2) ◽  
pp. 677-690 ◽  
Author(s):  
Wanli Wang ◽  
Jin Luo ◽  
Guiling Wang ◽  
Xi Zhu ◽  
Guiyi Liu

In this study, the operation of a ground source heat pump system was investigated over a 25-year period with careful attention paid to the effects of groundwater flow and intermittent operation strategies. First, geological and hydrogeological investigations were conducted, after which ground thermal properties were determined by thermal response tests. In order to predict the heat transfer within borehole heat exchangers under a specific operating system, a numerical model was developed using finite element subsurface flow & transport simulation system (FEFLOW). The numerical model was validated with thermal response test measurements. Three operation conditions including continuous system operation without groundwater flow, continuous system operation with groundwater flow, and intermittent operation with groundwater flow were examined. Results indicate that ground temperature disturbance was effectively reduced during groundwater flow and the intermittent operation of the system. Compared with continuous system operation without groundwater flow, the borehole heat exchanger heat transfer rate increases by 10% with groundwater flow conditions and increases by 16% with further implementation of the intermittent operation strategy. Intermittent operation with groundwater flow is highly recommended for the sustainable operation of ground source heat pump system.