Scanning Electron Microscopy of the Endothelial Surface of Small Diameter Vein Grafts in Rats Treated With Heparin

Author(s):  
C. M. Bannister ◽  
S. A. Chapman
Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 3062-3062
Author(s):  
Justin Barr ◽  
Jennifer Barr ◽  
Marielle Meurice ◽  
David Motto

Abstract Abstract 3062 Poster Board II-1038 VWF is a large plasma glycoprotein required for normal hemostasis, and performs its function through binding to coagulation Factor VIII, and via interactions with both platelet surface glycoproteins and the activated and/or damaged vascular surface. We have developed a scanning electron microscopy (SEM) protocol to visualize endothelial damage and thrombus formation in wild-type and VWF-deficient mice. Thrombus formation is initiated by ferric chloride, and subsequently at defined time points, the circulation is rapidly flushed and aldehyde fixed. The carotid artery is removed, externally fixed, sectioned (both longitudinally and in cross-section), processed for SEM, and visualized. With this protocol we have obtained high-quality images (exceeding 100,000x) of FeCl3-induced endothelial damage and thrombus formation in C57BL/6 and VWF-deficient mice at baseline, and at 30, 60, 90, 120, 240, and 300 seconds post-injury (please access http://sites.google.com/site/mottolab/ to view images). Interestingly, we find that FeCl3 induces little, if any, endothelial denudation and collagen exposure at these time points, with the endothelium clearly appearing changed from baseline, but not damaged. Thus, initial platelet adhesion seems to be occurring in the absence of collagen exposure in this model. In wild-type mice, platelets adhere rapidly to the endothelial surface and assume a cross-linked appearance by 90 seconds, with continual inward growth of the thrombus through the 300 second time point. In VWF-deficient mice, platelets also adhere rapidly to the endothelial surface, but in contrast, remain recognizable longer without assuming a highly-activated phenotype. Compared with wild-type, at all time points examined the VWF-deficient thrombus appears smaller with considerably less cross-linking and platelet activation. Interestingly, during the course of these experiments we also have identified what appears to be red blood cells (RBCs) participating in thrombus formation. Similar to platelets, RBCs interact directly with the endothelial surface, and subsequently become elongated in the direction of blood flow. These elongated RBCs are often observed to cluster and bind platelets, with the subsequent formation of large platelet-erythrocyte complexes. Further characterization of these complexes and the role they may play in thrombus formation is currently in progress. Additionally, similar SEM studies are underway with both ADAMTS13-deficient and GPIb alpha-deficient mice, and with mice transiently expressing in vivo biotinylated VWF for visualization of this molecule at high magnification and resolution. These studies should help better define the mechanisms of endothelial activation and thrombus formation as they occur in situ. Disclosures No relevant conflicts of interest to declare.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Archana Singh ◽  
Ankita Singh ◽  
Rajul Vivek ◽  
T. P. Chaturvedi ◽  
Pankaj Chauhan ◽  
...  

Implant fracture is one of the important biomechanical complications which can present with a considerable problem to the patient as well as the dental surgeon. The aim of this case report is to describe the management of a case of fractured endosseous dental implant in premolar region and microscopic evaluation of the fractured implant segment using scanning electron microscopy. In most of such cases, complete removal of the fractured implant has been a preferred treatment option. In the present case, fractured implant segment was successfully removed and rehabilitated immediately with larger diameter implant. It was found that retrieved fracture segment had a diameter of 3.3 mm, and SEM analysis shows fatigue fractures which may be the result of excessive overloading and use of small diameter implant which enhances fatigue failure.


2007 ◽  
Vol 22 (4) ◽  
pp. 1004-1011 ◽  
Author(s):  
B. Moser ◽  
K. Wasmer ◽  
L. Barbieri ◽  
J. Michler

A novel method for in situ scanning electron microscope (SEM) micro-compression tests is presented. The direct SEM observation during the instrumented compression testing allows for very efficient positioning and assessment of the failure mechanism. Compression tests on micromachined Si pillars with volumes down to 2 μm3are performed inside the SEM, and the results demonstrate the potential of the method. In situ observation shows that small diameter pillars tend to buckle while larger ones tend to crack before failure. Compressive strength increases with decreasing pillar diameter and reaches almost 9 GPa for submicrometer diameter pillars. This result is in agreement with earlier bending experiments on Si. Difficulties associated with precise strain measurements are discussed.


Author(s):  
P.S. Porter ◽  
T. Aoyagi ◽  
R. Matta

Using standard techniques of scanning electron microscopy (SEM), over 1000 human hair defects have been studied. In several of the defects, the pathogenesis of the abnormality has been clarified using these techniques. It is the purpose of this paper to present several distinct morphologic abnormalities of hair and to discuss their pathogenesis as elucidated through techniques of scanning electron microscopy.


Author(s):  
P.J. Dailey

The structure of insect salivary glands has been extensively investigated during the past decade; however, none have attempted scanning electron microscopy (SEM) in ultrastructural examinations of these secretory organs. This study correlates fine structure by means of SEM cryofractography with that of thin-sectioned epoxy embedded material observed by means of transmission electron microscopy (TEM).Salivary glands of Gromphadorhina portentosa were excised and immediately submerged in cold (4°C) paraformaldehyde-glutaraldehyde fixative1 for 2 hr, washed and post-fixed in 1 per cent 0s04 in phosphosphate buffer (4°C for 2 hr). After ethanolic dehydration half of the samples were embedded in Epon 812 for TEM and half cryofractured and subsequently critical point dried for SEM. Dried specimens were mounted on aluminum stubs and coated with approximately 150 Å of gold in a cold sputtering apparatus.Figure 1 shows a cryofractured plane through a salivary acinus revealing topographical relief of secretory vesicles.


Author(s):  
Nakazo Watari ◽  
Yasuaki Hotta ◽  
Yoshio Mabuchi

It is very useful if we can observe the identical cell elements within the same sections by light microscopy (LM), transmission electron microscopy (TEM) and/or scanning electron microscopy (SEM) sequentially, because, the cell fine structure can not be indicated by LM, while the color is; on the other hand, the cell fine structure can be very easily observed by EM, although its color properties may not. However, there is one problem in that LM requires thick sections of over 1 μm, while EM needs very thin sections of under 100 nm. Recently, we have developed a new method to observe the same cell elements within the same plastic sections using both light and transmission (conventional or high-voltage) electron microscopes.In this paper, we have developed two new observation methods for the identical cell elements within the same sections, both plastic-embedded and paraffin-embedded, using light microscopy, transmission electron microscopy and/or scanning electron microscopy (Fig. 1).


Sign in / Sign up

Export Citation Format

Share Document