Oxidation of No to No2 in Flue Gas Plumes of Power Stations

Author(s):  
A. J. Elshout ◽  
S. Beilke
2011 ◽  
Vol 356-360 ◽  
pp. 1516-1519 ◽  
Author(s):  
Jiang Wu ◽  
Jin Hong Zhang ◽  
Wei Feng Xu ◽  
Yu Ran Cai ◽  
Yuan Huang Ouyang ◽  
...  

Along with the rapid development of electric power industry in China, the pollutant discharge limits are getting more strict, and WFGD (wet flue gas desulfurization) technology and its equipment have been greatly developed and extensively applied, in which the gas-gas heater (GGH) is adopted at lots of the power stations. The corrosion is a very important issue in GGH, and it is experimentally studied in this paper. Through experiment of polarization curves and the control variable method, a comparative analysis of the corrosion resistance between the commonly used materials of the GGH is made. The results have shown that the corrosion resistance with the heat transfer surface in GGH will decrease with the temperature increasing, but the enamel steel’s corrosion resistance and stability is strikingly better than that of others, and the increasing volume of corrosion resistance by plating enamel is remarkable.


1998 ◽  
Vol 17 (8) ◽  
pp. 523-533 ◽  
Author(s):  
James C. Hower ◽  
Uschi M. Graham ◽  
Amy S. Wong ◽  
J.David Robertson ◽  
Bethel O. Haeberlin ◽  
...  

1982 ◽  
Vol 61 (4) ◽  
pp. 276-284
Author(s):  
Nobuaki MURAKAMI ◽  
Nobuyuki KOJIMA ◽  
Minoru HASHIGUCHI
Keyword(s):  
Flue Gas ◽  

2015 ◽  
Vol 36 (4) ◽  
pp. 405-423 ◽  
Author(s):  
Charlene Ramsunkar ◽  
Chris van Tonder ◽  
Walter Schmitz

Abstract Boiler combustion air is generally controlled by the excess air content measured at the boiler economiser outlet using oxygen (O2) analysers. Due to duct geometry and dimensions, areas of high and low O2 concentrations in the flue gas duct occur, which poses a problem in obtaining a representative measurement of O2 in the flue gas stream. Multipoint systems as opposed to single point systems are more favourable to achieve representative readings. However, ash blockages and air leakages influence the accuracy of O2 measurement. The design of multipoint system varies across ESKOMs’ Power Stations. This research was aimed at evaluating the accuracy of the multipoint oxygen measurement system installed at Power Station A and to determine the systematic errors associated with different multipoint systems designs installed at Power Stations' A and B. Using flow simulation software, FloEFDTM and Flownex®, studies were conducted on two types of multipoint system designs This study established that significantly large errors, as high as 50%, were noted between the actual and measured flue gas O2. The design of the multipoint system extraction pipes also introduces significant errors, as high as 23%, in the O2 measured. The results indicated that the sampling errors introduced with Power Station A’s system can be significantly reduced by adopting the sampling pipe design installed at Power Station B.


Author(s):  
A C Lua ◽  
R F Boucher

A coal-cleaning technique was evaluated to determine its effectiveness to remove sulphur and ash contents of dry pulverized coals before combustion in power stations. Dry high-gradient magnetic separation (HGMS) experiments were conducted on a British coal from Coalfield Farm North using ferromagnetic stainless steel wire meshes as the separator matrix which was located in the bore of a superconducting solenoid magnet. The parametric effects of magnetic field, air velocity and separator length on the process were investigated. Increasing magnetic fields and separator lengths and decreasing air velocities each individually increases the percentage reductions of pyritic sulphur, total sulphur and ash. Reduction efficiencies up to 91, 65 and 61 per cent for pyritic sulphur, total sulphur and ash respectively were obtained. These results have at least shown that dry HGMS could possibly provide a simple and economic alternative to flue gas desulphurization to reduce sulphur dioxide emissions to the atmosphere from coal-fired power stations, with the additional benefit of an ash removal capability.


Sign in / Sign up

Export Citation Format

Share Document