Exergy Analysis of Dedicated Mechanically Subcooled Vapour Compression Refrigeration Cycle Using HFC-R134a, HFO-R1234ze and R1234yf

Author(s):  
Shyam Agarwal ◽  
Akhilesh Arora ◽  
B. B. Arora
Author(s):  
Kenneth C. Brown

A remote area power supply using cold thermal storage and wind as the energy source is proposed. The primary objective is to provide a renewable energy remote area power supply with cheaper and more robust storage than lead-acid batteries. The proposal amalgamates a vapour compression refrigeration system with a Rankine cycle engine, both using the same working fluid. A tank of freezing brine acts as the condenser in the Rankine cycle and as the evaporator in the refrigeration cycle but also provides the “energy storage”. Analysis of the system indicates that it is practical and that its performance is comparable with existing battery based systems.


2019 ◽  
Vol 9 (23) ◽  
pp. 5028 ◽  
Author(s):  
Pektezel ◽  
Acar

This paper presents energy and exergy analysis of two vapor compression refrigeration cycles powered by organic Rankine cycle. Refrigeration cycle of combined system was designed with single and dual evaporators. R134a, R1234ze(E), R227ea, and R600a fluids were used as working fluids in combined systems. Influences of different parameters such as evaporator, condenser, boiler temperatures, and turbine and compressor isentropic efficiencies on COPsys and ƞex,sys were analyzed. Second law efficiency, degree of thermodynamic perfection, exergy destruction rate, and exergy destruction ratio were detected for each component in systems. R600a was determined as the most efficient working fluid for proposed systems. Both COPsys and ƞex,sys of combined ORC-single evaporator VCR cycle was detected to be higher than the system with dual evaporator.


2014 ◽  
Vol 984-985 ◽  
pp. 1174-1179
Author(s):  
N. Austin ◽  
P.M. Diaz ◽  
D.S. Manoj Abraham ◽  
N. Kanthavelkumaran

Study on environment friendly mixed refrigerant to replace R134a in vapour compression refrigeration (VCR) System. The mixed refrigerants investigated are propane (R290), butane (R600), isobutene (R600a) and R134a. Even though the ozone depletion potentials of R134a relative to CFC-11 are very low; the global warming potentials are extremely high and also expensive. For this reason, the production and use of R134a will be terminated in the near future. Hydrocarbons are free from ozone depletion potential and have negligible global warming potential. The results showed that, mixed refrigerant with charge of 80 g satisfy the required freezer air temperature when R134a with a charge of 110 g is used as refrigerant. The actual COP of refrigerator using mixed refrigerant was almost nearer that of the system using R134a as refrigerant. The coefficient of performance of the vapour compression refrigeration system using mixed refrigerant MR-3 [R134a/R290/ R600a/ R600 (20/35/40/5)] is having very close value with R134a and the Global warming potential of MR-3 is negligible when compared with R134a. Hence the mixed refrigerant MR-3 is chosen as an environmental friendly alternate refrigerant to R134a. The exergy analysis of the vapour compression refrigeration system using R134a and all the above mixtures are investigated. The effect of evaporator temperature on exergy efficiency and exergy destruction ratio of the system are experimentally studied. The exergy defect in the compressor, condenser, expansion device and evaporator are also obtained. Key words: R134a, Mixed refrigerant, Chlorofluorocarbons, Propane, Butane, Isobutene, REFPROP, COP, ODP, GWP, Exergy, VCR System.