Development of Portable Device to Measure Respiratory Activity Based on Impedance Pneumography

Author(s):  
G. E. Cañadas ◽  
C. R. Dell’Aquila ◽  
E. Laciar
Sensors ◽  
2021 ◽  
Vol 21 (18) ◽  
pp. 6233
Author(s):  
Marcel Młyńczak ◽  
Hubert Krysztofiak

The current diagnostic procedures for assessing physiological response to exercise comprise blood lactates measurements, ergospirometry, and electrocardiography. The first is not continuous, the second requires specialized equipment distorting natural breathing, and the last is indirect. Therefore, we decided to perform the feasibility study with impedance pneumography as an alternative technique. We attempted to determine points in respiratory-related signals, acquired during stress test conditions, that suggest a transition similar to the gas exchange threshold. In addition, we analyzed whether or not respiratory activity reaches steady states during graded exercise. Forty-four students (35 females), practicing sports on different levels, performed a graded exercise test until exhaustion on cycloergometer. Eventually, the results from 34 of them were used. The data were acquired with Pneumonitor 2. The signals demonstrated that the steady state phenomenon is not as evident as for heart rate. The results indicated respiratory rate approaches show the transition point at the earliest (more than 6 min before the end of the exercise test on average), and the tidal volume ones at the latest (less than 5 min). A combination gave intermediate findings. The results showed the impedance pneumography appears reasonable for the transition point estimation, but this should be further studied with the reference.


2013 ◽  
Vol 83 (2) ◽  
pp. 122-128 ◽  
Author(s):  
Cécile Renaud ◽  
Jacques Berger ◽  
Arnaud Laillou ◽  
Sylvie Avallone

Vitamin A deficiency is still one of the major public health problems in least developed countries. Fortification of vegetable oils is a strategy implemented worldwide to prevent this deficiency. For a fortification program to be effective, regular monitoring is necessary to control food quality in the producing units. The reference methods for vitamin A quantification are expensive and time-consuming. A rapid method should be useful for regular assessment of vitamin A in the oil industry. A portable device was compared to high-performance liquid chromatography (HPLC) for three plant oils (rapeseed, groundnut, and soya). The device presented a good linearity from 3 to 30 mg retinol equivalents per kg (mg RE.kg- 1). Its limits of detection and quantification were 3 mg RE.kg- 1 for groundnut and rapeseed oils and 4 mg RE.kg- 1 for soya oil. The intra-assay precision ranged from 1.48 % to 3.98 %, considered satisfactory. Accuracy estimated by the root mean squares error ranged from 3.99 to 5.49 and revealed a lower precision than HPLC (0.4 to 2.25). Although it offers less precision than HPLC, the device estimates quickly the vitamin A content of the tested oils from 3 or 4 to 15 mg RE.kg- 1.


2016 ◽  
Vol 136 (5) ◽  
pp. 142-147
Author(s):  
Yusuke Harada ◽  
Yoshinori Matsumoto

2001 ◽  
Vol 91 (6) ◽  
pp. 2703-2712 ◽  
Author(s):  
Stephen M. Johnson ◽  
Julia E. R. Wilkerson ◽  
Daniel R. Henderson ◽  
Michael R. Wenninger ◽  
Gordon S. Mitchell

Brain stem preparations from adult turtles were used to determine how bath-applied serotonin (5-HT) alters respiration-related hypoglossal activity in a mature vertebrate. 5-HT (5–20 μM) reversibly decreased integrated burst amplitude by ∼45% ( P < 0.05); burst frequency decreased in a dose-dependent manner with 20 μM abolishing bursts in 9 of 13 preparations ( P < 0.05). These 5-HT-dependent effects were mimicked by application of a 5-HT1A agonist, but not a 5-HT1B agonist, and were abolished by the broad-spectrum 5-HT antagonist, methiothepin. During 5-HT (20 μM) washout, frequency rebounded to levels above the original baseline for 40 min ( P < 0.05) and remained above baseline for 2 h. A 5-HT3 antagonist (tropesitron) blocked the post-5-HT rebound and persistent frequency increase. A 5-HT3 agonist (phenylbiguanide) increased frequency during and after bath application ( P < 0.05). When phenylbiguanide was applied to the brain stem of brain stem/spinal cord preparations, there was a persistent frequency increase ( P < 0.05), but neither spinal-expiratory nor -inspiratory burst amplitude were altered. The 5-HT3receptor-dependent persistent frequency increase represents a unique model of plasticity in vertebrate rhythm generation.


iScience ◽  
2021 ◽  
Vol 24 (5) ◽  
pp. 102442
Author(s):  
Jihoon Chung ◽  
Deokjae Heo ◽  
Kyunghwan Cha ◽  
Zong-Hong Lin ◽  
Jinkee Hong ◽  
...  

Author(s):  
Roberto A. Sussman ◽  
Eliana Golberstein ◽  
Riccardo Polosa

We discuss the implications of possible contagion of COVID-19 through e-cigarette aerosol (ECA) for prevention and mitigation strategies during the current pandemic. This is a relevant issue when millions of vapers (and smokers) must remain under indoor confinement and/or share public outdoor spaces with non-users. The fact that the respiratory flow associated with vaping is visible (as opposed to other respiratory activities) clearly delineates a safety distance of 1–2 m along the exhaled jet to prevent direct exposure. Vaping is a relatively infrequent and intermittent respiratory activity for which we infer a mean emission rate of 79.82 droplets per puff (6–200, standard deviation 74.66) comparable to mouth breathing, it adds into shared indoor spaces (home and restaurant scenarios) a 1% extra risk of indirect COVID-19 contagion with respect to a “control case” of existing unavoidable risk from continuous breathing. As a comparative reference, this added relative risk increases to 44–176% for speaking 6–24 min per hour and 260% for coughing every 2 min. Mechanical ventilation decreases absolute emission levels but keeps the same relative risks. As long as direct exposure to the visible exhaled jet is avoided, wearing of face masks effectively protects bystanders and keeps risk estimates very low. As a consequence, protection from possible COVID-19 contagion through vaping emissions does not require extra interventions besides the standard recommendations to the general population: keeping a social separation distance of 2 m and wearing of face masks.


Author(s):  
Nathalie Samson ◽  
Charlène Nadeau ◽  
Danny Cantin ◽  
Rezkalla Farkouh ◽  
Maggy Robinson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document