Approximate calculation of the axisymmetric motions of a pipe wall in explosive welding

1971 ◽  
Vol 4 (2) ◽  
pp. 153-155 ◽  
Author(s):  
R. P. Didyk ◽  
S. S. Krasnovskii ◽  
A. G. Teslenko
2020 ◽  
pp. 49-52
Author(s):  
R.A. Okulov ◽  
N.V. Semenova

The change in the intensity of the deformation of the pipe wall during profiling by drawing was studied. The dependence of the strain intensity on the wall thickness of the workpiece is obtained to predict the processing results in the production of shaped pipes with desired properties. Keywords drawing, profile pipe, wall thickness, strain rate. [email protected]


1994 ◽  
Vol 59 (3) ◽  
pp. 603-615 ◽  
Author(s):  
Václav Dolejš ◽  
Ivan Machač ◽  
Petr Doleček

The paper presents a modification of the equations of Rabinowitsch-Mooney type for an approximate calculation of pressure drop in laminar flow of generalized Newtonian liquid through a straight channel whose cross section forms a simple continuous area. The suitability of the suggested procedure of calculation of pressure drop is demonstrated by the comparison of calculation results with both the published and original results of numerical solution and experiments.


Coatings ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 301
Author(s):  
Jiaqi Chen ◽  
Hao Wang ◽  
Milad Salemi ◽  
Perumalsamy N. Balaguru

Carbon fiber reinforced polymer (CFRP) matrix composite overwrap repair systems have been introduced and accepted as an alternative repair system for steel pipeline. This paper aimed to evaluate the mechanical behavior of damaged steel pipeline with CFRP repair using finite element (FE) analysis. Two different repair strategies, namely wrap repair and patch repair, were considered. The mechanical responses of pipeline with the composite repair system under the maximum allowable operating pressure (MAOP) was analyzed using the validated FE models. The design parameters of the CFRP repair system were analyzed, including patch/wrap size and thickness, defect size, interface bonding, and the material properties of the infill material. The results show that both the stress in the pipe wall and CFRP could be reduced by using a thicker CFRP. With the increase in patch size in the hoop direction, the maximum von Mises stress in the pipe wall generally decreased as the maximum hoop stress in the CFRP increased. The reinforcement of the CFRP repair system could be enhanced by using infill material with a higher elastic modulus. The CFRP patch tended to cause higher interface shear stress than CFRP wrap, but the shear stress could be reduced by using a thicker CFRP. Compared with the fully bonded condition, the frictional interface causes a decrease in hoop stress in the CFRP but an increase in von Mises stress in the steel. The study results indicate the feasibility of composite repair for damaged steel pipeline.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Christoph Kandlbinder-Paret ◽  
Alice Fischerauer ◽  
Gerhard Fischerauer

Abstract In electrical capacitance tomography (ECT), the resolution of the reconstructed permittivity distribution improves with the number of electrodes used whereas the number of capacitance measurements and the measurement time increases with the number of electrodes. To cope with this tradeoff, we present a phantom-dependent adaptation scheme in which coarse measurements are performed with terminal electrodes interconnected to form a synthetic electrode ring with fewer but larger electrodes. The concept was tested by observing the sloshing of water inside a pipe. We compare the reconstructed results based on eight synthetic electrodes, on 16 elementary electrodes, and on the adaptation scheme involving both the eight synthetic electrodes and some of the elementary capacitances. The reconstruction used the projected Landweber algorithm for capacitances determined by a finite-element simulation and for measured capacitances. The results contain artefacts attributed to the influence of the high permittivity of water compared to the low permittivity of the pipe wall. The adaptation scheme leads to nearly the same information as a full measurement of all 120 elementary capacitances but only requires the measurement of 30 % fewer capacitances. By detecting the fill level using a tomometric method, it can be determined within an uncertainty of 5 % FS.


Materials ◽  
2017 ◽  
Vol 10 (9) ◽  
pp. 984 ◽  
Author(s):  
Qiang Zhou ◽  
Jianrui Feng ◽  
Pengwan Chen

Fluids ◽  
2021 ◽  
Vol 6 (6) ◽  
pp. 208
Author(s):  
Liuyang Ding ◽  
Tyler Van Buren ◽  
Ian E. Gunady ◽  
Alexander J. Smits

Pipe flow responds to strong perturbations in ways that are fundamentally different from the response exhibited by boundary layers undergoing a similar perturbation, primarily because of the confinement offered by the pipe wall, and the need to satisfy continuity. We review such differences by examining previous literature, with a particular focus on the response of pipe flow to three different kinds of disturbances: the abrupt change in surface condition from rough to smooth, the obstruction due to presence of a single square bar roughness elements of different sizes, and the flow downstream of a streamlined body-of-revolution placed on the centerline of the pipe. In each case, the initial response is strongly influenced by the pipe geometry, but far downstream all three flows display a common feature, which is the very slow, second-order recovery that can be explained using a model based on the Reynolds stress equations. Some future directions for research are also given.


Sign in / Sign up

Export Citation Format

Share Document