Further development of BMW’s fully-variable valve control system valvetronic

MTZ worldwide ◽  
2005 ◽  
Vol 66 (9) ◽  
pp. 10-13 ◽  
Author(s):  
Klaus Benedikt ◽  
Gottfried Drexler ◽  
Torsten Eder ◽  
Markus Eisenkoelbl ◽  
Christoph Luttermann ◽  
...  
1999 ◽  
Author(s):  
Takaaki Tsukui ◽  
Koji Tsutsumizaki ◽  
Mutsuo Nakajima

2014 ◽  
Vol 977 ◽  
pp. 334-337
Author(s):  
Xi Lei ◽  
Gui Zhi Xu ◽  
Ke Zheng Xing

As a flexible AC transmission system equipment, controlled shunt reactor is becoming increasingly important in the grid with the development of EHV / UHV transmission systems. Since currently rated voltage of controlled shunt reactor has developed to 1100kV, as its capacity control system, or valve-control system, stability and reliability test is very important. In this paper, the test circuit and method for the valve-control system in the laboratory or the test station for combined adjustment test is put forward. By adjustment of power supply and the device parameter, the valve-control system can put the voltage and current of the device to be the same as the on-set operation. Actual test of the world's first 1100kV controlled shunt reactor valve-control system shows that, the test method in this paper is correct and feasible, and the objective of assessment can be achieved.


2012 ◽  
Author(s):  
Takahiro Miura ◽  
Shunichi Aoyama ◽  
Kaoru Onogawa ◽  
Takaya Fujia ◽  
Tetsuro Murata ◽  
...  

1999 ◽  
Author(s):  
Qingfeng Wang ◽  
Linyi Gu ◽  
Yongxiang Lu

Abstract The smoothness of acceleration and deceleration process is a serious problem in valve control system with high inertia load, especially in the hydraulic systems in construction machines. In this paper, a meter-in and meter-out independent regulating method, in which the two sides of actuator are controlled by a meter-in valve and a meter-out valve respectively, is put forward, in one hand, the meter-out valve could control the actuator’s outlet pressure to avoid the ultra-high outlet pressure when actuator decelerates or brakes suddenly. On the other hand, the dynamic damping ratio of valve control system could be raised through calculated flow feedback control algorithm. Secondly, a grading control algorithm in dynamic process of high inertia load is adopted. When the actuator’s velocity is far from its command value, the actuator’s inlet and outlet pressure are controlled. After the velocity error decrease to a threshold, a state feedback control algorithm based on parameters on line estimating is employed to realize both its velocity accuracy and the smoothness of dynamic process. Experiments show that the actuator’s velocity could increase or decrease to its command value accurately, smoothly and rapidly after the above method and algorithm are applied.


2018 ◽  
Vol 769 ◽  
pp. 371-376 ◽  
Author(s):  
Elena Alexandrovna Muravyova ◽  
Alexander Ivanovich Kubryak

The article describes the development of a mathematical model for a condenser-evaporator, which occupies a central position in chlorine liquefaction process. The model describes the key processes in the equipment unit: freon evaporation, chlorine condensation, change in freon level and in equipment pressure. The model is based on the equations characterizing the processes mentioned above, which makes it possible to use the model for design and calculations of non-contact heat transfer equipment with phase transitions of heat carriers of various characteristics. The simulation was carried out with the aim of further development of a condenser-evaporator control system.


2020 ◽  
Vol 18 (5) ◽  
pp. 1231-1240
Author(s):  
Lianyu Wang

Purpose Intelligent lighting control system can control lights to go off when people leave, which has been widely concerned by researchers. Design/methodology/approach In this study, an intelligent lighting control system based on wireless sensor network was designed. First, the hardware and software designs of the system were described briefly. Then, the lighting control algorithm was analyzed emphatically. Considering the illumination and uniformity of light, an intelligent lighting control algorithm based on gradient descent was designed. Findings In the system test, it was found that the system had a good through-wall communication function, and the communication distance could fully meet the system requirements and run normally. In the test of the lighting control algorithm, it was found that the user’s satisfaction on uniformity in different scenarios was close to 1, and the satisfaction on illumination could also meet the user’s needs, which verified the reliability of the lighting control algorithm. Originality/value This study provides some theoretical supports for the better application of wireless sensor network in intelligent light control system, which is conducive to the further development of light control system.


Sign in / Sign up

Export Citation Format

Share Document