scholarly journals New closed-loop insulin systems

Diabetologia ◽  
2021 ◽  
Author(s):  
Charlotte K. Boughton ◽  
Roman Hovorka

AbstractAdvances in diabetes technologies have enabled the development of automated closed-loop insulin delivery systems. Several hybrid closed-loop systems have been commercialised, reflecting rapid transition of this evolving technology from research into clinical practice, where it is gradually transforming the management of type 1 diabetes in children and adults. In this review we consider the supporting evidence in terms of glucose control and quality of life for presently available closed-loop systems and those in development, including dual-hormone closed-loop systems. We also comment on alternative ‘do-it-yourself’ closed-loop systems. We remark on issues associated with clinical adoption of these approaches, including training provision, and consider limitations of presently available closed-loop systems and areas for future enhancements to further improve outcomes and reduce the burden of diabetes management. Graphical abstract

2021 ◽  
pp. 193229682110354
Author(s):  
Aideen Daly ◽  
Sara Hartnell ◽  
Charlotte K. Boughton ◽  
Mark Evans

Background: Gastroparesis is associated with unpredictable gastric emptying and can lead to erratic glucose profiles and negative impacts on quality-of-life. Many people with gastroparesis are unable to meet glycemic targets and there is a need for new approaches for this population. Hybrid closed-loop systems improve glucose control and quality-of-life but evidence for their use in people with diabetic gastroparesis is limited. Methods: We present a narrative review of the challenges associated with type 1 diabetes management for people with gastroparesis and present a case series of 7 people with type 1 diabetes and gastroparesis. We compare glycemic control before and during the first 12 months of hybrid closed-loop therapy. Data were analyzed using electronic patient records and glucose management platforms. We also discuss future advancements for closed-loop systems that may benefit this population. Results: Five of 7 patients had data available for time in range before and during hybrid closed-loop therapy, and all had an improvement in percentage time in target glucose range, with the overall mean time in range increasing from 26.0% ± 15.7% to 58.4% ± 8.6% during HCL use, ( P = .004). There were significant reductions in HbA1c (83 ± 9 mmol/mol to 71 ± 14 mmol/mol) and mean glucose from 13.0 ± 1.7 mmol/L (234 ± 31 mg/dL) to 10.0 ± 0.7 mmol/L (180 ± 13 mg/dL) with use of a hybrid closed-loop system. Importantly, this was achieved without an increase in time in hypoglycemia ( P = .50). Conclusion: Hybrid closed-loop systems may represent a valuable approach to improve glycemic control for people with type 1 diabetes and gastroparesis. Prospective studies are required to confirm these findings.


2020 ◽  
Vol 11 ◽  
pp. 204201882095014
Author(s):  
Zekai Wu ◽  
Sihui Luo ◽  
Xueying Zheng ◽  
Yan Bi ◽  
Wen Xu ◽  
...  

Background: Previous studies show that the use of do-it-yourself artificial pancreas system (DIYAPS) may be associated with better glycemic control characterized by improved estimated hemoglobin A1c (eHbA1c) and time in range among adults with type 1 diabetes (T1D). However, few studies have demonstrated the changes in laboratory-measured HbA1c, which is a more accepted index for glycemic control, after using a DIYAPS. Methods: This is a retrospective before-after study approaching patients who reported self-use of AndroidAPS. The main inclusion criteria included: T1D; aged ⩾18 years; having complete record of ⩾3 months of continuous AndroidAPS use; with laboratory-measured HbA1c and quality of life scale data before and after 3 months of AndroidAPS use; and not pregnant. The primary outcome was the change in HbA1c between baseline and 3 months after initiation of AndroidAPS use. Results: Overall, 15 patients (10 females) were included; the median age was 32.2 years (range: 19.2–69.4), median diabetes duration was 9.7 years (range: 1.8–23.7) and median baseline HbA1c was 7.3% (range: 6.4–10.1). The 3 months of AndroidAPS use was associated with substantial reductions in HbA1c [6.79% (SD: 1.29) versus 7.63% (SD: 1.06), p = 0.002] and glycemic variability when compared with sensor-augmented pump therapy. A lower level of fear of hypoglycemia [22.13 points (SD: 6.87) versus 26.27 points (SD: 5.82), p = 0.010] was also observed after using AndroidAPS. Conclusions: The 3 months of AndroidAPS use was associated with significant improvements in glucose management and quality of life among adults with T1D.


2020 ◽  
pp. 193229682097842
Author(s):  
William H. Polonsky ◽  
Addie L. Fortmann

Background: To examine caregivers’ experiences with real-time continuous glucose monitoring (RT-CGM) data sharing and its impact on quality of life (QoL) and health outcomes. Methods: Parents of children with type 1 diabetes (T1D) ( N = 303) and spouses/partners of T1D adults ( N = 212) using the Dexcom G5 Mobile or G6 RT-CGM system and who were actively following their T1Ds’ RT-CGM data completed a survey examining their perceived value of data sharing, the impact of sharing on their own QoL and their child/partner’s health, and how they used RT-CGM data to support their T1Ds’ diabetes management. Regression analyses examined whether their actions were linked to reported changes in QoL and health outcomes. Results: Respondents were predominantly non-Hispanic White (91.1% parents; 88.7% partners), female (78.2% parents; 54.7% partners), and college-educated (65.3% parents; 61.8% partners). The majority reported that data sharing had enhanced hypoglycemic confidence (97.7% parents; 98.1% partners), overall well-being (60.4% parents; 63.2% partners), and sleep quality (78.0% parents; 61.3% partners). Of note, three positive caregiver actions were broadly consistent and significant predictors of QoL and health benefits for both parents and partners: celebrating success related to glycemic control, providing encouragement when glycemic control is challenging, and teamwork discussions about how the caregiver should respond to out-of-range values. Conclusions: RT-CGM data sharing was associated with a range of QoL and health benefits for caregivers. Degree of benefits was influenced by the collaborative actions taken by caregivers to support their child’s or partner’s diabetes management. To determine the most effective strategies for collaborative data sharing, longitudinal trials are needed.


2010 ◽  
Vol 6 (2) ◽  
pp. 31
Author(s):  
Lalantha Leelarathna ◽  
Roman Hovorka ◽  
◽  

Automated insulin delivery by means of a glucose-responsive closed-loop system has often been cited as the ‘holy grail’ of type 1 diabetes management. Reflecting the technological advances in interstitial glucose measurements and wider use of continuous glucose monitoring, recent research in closed-loop glucose control has focused on the subcutaneous route for glucose measurements and insulin delivery. The primary aim of such systems is to keep blood glucose within the target range while minimising the risk of hypoglycaemia with minimal input from the user. This article examines recent developments in the field of interstitial glucose measurement, limitations of the current generation of devices and implications on the performance of closed-loop systems. Clinical results and the advantages and disadvantages of different closed-loop configurations are summarised. Potential future advances in closed-loop systems are highlighted.


Author(s):  
Andrea Lukács ◽  
Péter Sasvári ◽  
András Török ◽  
László Barkai

AbstractThis study aimed to evaluate the health-related quality of life (HRQoL) of adolescents with type 1 diabetes (T1DM) on the basis of the pediatric quality of life inventory™ (PedsQL™) generic and diabetes-specific modules, and to compare it to that of healthy peers.This retrospective case-control study involved 650 participants between ages of 13 and 19 years including 296 adolescents with T1DM from four diabetes centers and 354 healthy peers matched for age and gender from three different cities of the country. Participants completed the validated PedsQL™ for assessing the HRQoL. The analysis included an independent t-test to compare the means of the total and subscales of the PedsQL™ between boys and girls as well as between a healthy group and a group with T1DM. Gender differences in exercise, insulin therapy modalities were evaluated with the Pearson χAdolescents with T1DM have similar HRQoL in all domains when compared to their healthy counterparts. Females report worse HRQoL regardless of the presence of the disease. Insulin pump therapy facilitates better glycemic control and HRQoL. Regular exercise positively correlates with the generic HRQoL in both groups; however, it has no relationship with glycemic control.Optimal metabolic control and improved HRQoL are the eventual goals of diabetes management. Despite the difficulties, adolescents with diabetes can manage their disease well and live normal lives, similar to their healthy peers. Although diabetes-related problems exist, it seems that regular exercise and staying physically active, as well as promoting insulin pump therapy where it is applicable are related to favorable HRQoL.


2018 ◽  
Vol 19 (7) ◽  
pp. 1322-1330 ◽  
Author(s):  
James W Varni ◽  
Alan M Delamater ◽  
Korey K Hood ◽  
Kimberly A Driscoll ◽  
Jenise C Wong ◽  
...  

2010 ◽  
Vol 06 (01) ◽  
pp. 58
Author(s):  
Lalantha Leelarathna ◽  
Roman Hovorka ◽  
◽  

Automated insulin delivery by means of a glucose-responsive closed-loop system has often been cited as the ‘holy grail’ of type 1 diabetes management. Reflecting the technological advances in interstitial glucose measurements and wider use of continuous glucose monitoring, recent research in closed-loop glucose control has focused on the subcutaneous route for glucose measurements and insulin delivery. The primary aim of such systems is to keep blood glucose within the target range while minimizing the risk of hypoglycemia with minimal input from the user. This article examines recent developments in the field of interstitial glucose measurement, limitations of the current generation of devices and implications on the performance of closed-loop systems. Clinical results and the advantages and disadvantages of different closed-loop configurations are summarized. Potential future advances in closed-loop systems are highlighted.


Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 121-LB
Author(s):  
AHMED H. ELDIB ◽  
ELENA TOSCHI ◽  
NOOR MAHMOUD ◽  
MHD WAEL TASABEHJI ◽  
SAHAR ASHRAFZADEH ◽  
...  