D-dimer assay predicts mortality in critically ill patients without disseminated intravascular coagulation or venous thromboembolic disease

1999 ◽  
Vol 25 (2) ◽  
pp. 207-210 ◽  
Author(s):  
R. F. Trotta ◽  
L. F. Diehl ◽  
A. F. Shorr ◽  
G. S. Hanzel ◽  
S. A. Alkins
2022 ◽  
Vol 28 ◽  
pp. 107602962110705
Author(s):  
Nozomi Ikeda ◽  
Hideo Wada ◽  
Yuhuko Ichikawa ◽  
Minoru Ezaki ◽  
Motoko Tanaka ◽  
...  

Introduction Although D-dimer is a useful biomarker of thrombosis, there are many D-dimer kits, with high and low fibrinogen and fibrin degradation products (FDP)/ D-dimer ratios. Methods Plasma D-dimer levels were measured using three different kits in critically ill patients to examine the usefulness of such measurements for detecting the thrombotic diseases and determining the correlation with the FDP and FDP/D-dimer ratio. Results Although three D-dimer kits showed marked utility for diagnosing disseminated intravascular coagulation (DIC) and peripheral arterial and venous thromboembolism (PAVTE), the D-dimer levels determined using the three kits varied among diseases. Indeed, one D-dimer kit showed a high FDP/D-dimer ratio, and another kit showed a low FDP/D-dimer ratio. D-dimer kit with low FDP/D-dimer ratio tended to have high cut-off values and low specificity for diagnosing DIC and PAVTE. In D-dimer kit with high FDP/D-dimer ratio, FDP/D-dimer ratios in patients with thrombosis was significantly higher than that in patients without thrombosis. Conclusion All three D-dimer kits show utility for detecting thrombotic diseases. However, the D-dimer levels determined using the kits varied due to differences in the FDP/D-dimer ratio. In combination with the FDP level, a D-dimer kit with a high FDP/D-dimer ratio may be useful.


2019 ◽  
Vol 35 (3) ◽  
pp. 225-232
Author(s):  
Yuri Matusov ◽  
Aaron S. Weinberg ◽  
Richard Liang ◽  
Joseph Meza ◽  
Oren Friedman ◽  
...  

Venous thromboembolic disease is a major problem among critically ill patients, with significant associated morbidity and mortality. Many critically ill patients have contraindications to systemic anticoagulation, and inferior vena cava (IVC) filters are an important alternative in preventing pulmonary emboli (PE) in this population. The Angel Catheter (Mermaid, Stenlose, Denmark) is a novel percutaneous and removable IVC filter attached to the end of a triple lumen central venous catheter which has been demonstrated to reduce PE in surgical and trauma patients. This case series describes 18 critically ill medical patients who had an Angel catheter placed either for diagnosed PE or due to high risk for PE; over half had at least submassive PE at the time of Angel catheter placement. None of the patients had a recurrence of PE during Angel catheter use, 29.4% had clot found in the filter via cavogram upon removal, and only one had a minor complication which had no clinical consequence. In 2 patients, the placement of the Angel Catheter resulted in the prevention of PE during catheter-directed thrombolysis of extensive deep vein thrombosis. This case series demonstrates that in a population of critically ill, elderly, and obese medical patients the bedside placement of the Angel IVC filter is feasible, safe, and may be effective for preventing PE.


2021 ◽  
Vol 10 (13) ◽  
pp. 2860
Author(s):  
Akitaka Yamamoto ◽  
Hideo Wada ◽  
Yuhuko Ichkawa ◽  
Motoko Tanaka ◽  
Haruhiko Tashiro ◽  
...  

Disseminated intravascular coagulation (DIC) is induced by excess activation coagulation, and activated platelets are also involved in pathogenesis. Therefore, plasma levels of soluble C-type lectin-like receptor 2 (sCLEC-2), a new marker for platelet activation, can be expected as a marker of DIC in critically ill patients. Plasma levels of sCLEC-2 and D-dimer were measured using the STACIA system. Plasma sCLEC-2 and D-dimer levels were significantly higher in patients with underlying diseases of DIC than in those with unidentified clinical syndrome (UCS). Plasma sCLEC-2 levels were significantly higher in the patients with DIC and Pre-DIC than in those without DIC or Pre-DIC. Similarly, plasma D-dimer levels were also significantly higher in patients with DIC and Pre-DIC than in those without DIC or Pre-DIC. The plasma sCLEC-2 levels in all patients and those with a DIC score ≤ 4 were significantly higher in non-survivors than survivors. The plasma D-dimer levels in all patients, those with a DIC score ≥ 5 and those with a DIC score ≤ 4, were significantly higher in non-survivors than in survivors. The plasma sCLEC-2 is expected as a marker for DIC/Pre-DIC as well as the prognostic marker in critically ill patients.


2018 ◽  
Vol 42 (2) ◽  
pp. 135-136
Author(s):  
R. Viejo Moreno ◽  
J.A. Sánchez-Izquierdo Riera ◽  
E. Molano Álvarez ◽  
J.A. Barea Mendoza ◽  
S. Temprano Vázquez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document