Spatial effects of nutrient pollution on drinking water production

Author(s):  
Roberto Mosheim ◽  
Robin C. Sickles
2004 ◽  
Vol 4 (5-6) ◽  
pp. 215-222 ◽  
Author(s):  
A.R. Costa ◽  
M.N. de Pinho

Membrane fouling by natural organic matter (NOM), namely by humic substances (HS), is a major problem in water treatment for drinking water production using membrane processes. Membrane fouling is dependent on membrane morphology like pore size and on water characteristics namely NOM nature. This work addresses the evaluation of the efficiency of ultrafiltration (UF) and Coagulation/Flocculation/UF performance in terms of permeation fluxes and HS removal, of the water from Tagus River (Valada). The operation of coagulation with chitosan was evaluated as a pretreatment for minimization of membrane fouling. UF experiments were carried out in flat cells of 13.2×10−4 m2 of membrane surface area and at transmembrane pressures from 1 to 4 bar. Five cellulose acetate membranes were laboratory made to cover a wide range of molecular weight cut-off (MWCO): 2,300, 11,000, 28,000, 60,000 and 75,000 Da. Severe fouling is observed for the membranes with the highest cut-off. In the permeation experiments of raw water, coagulation prior to membrane filtration led to a significant improvement of the permeation performance of the membranes with the highest MWCO due to the particles and colloidal matter removal.


1994 ◽  
Vol 30 (10) ◽  
pp. 221-227 ◽  
Author(s):  
Jordi Martín-Alonso

The Llobregat is a 156 km long river, which supplies 35% of the Barcelona's drinking water needs from the Sant Joan Despí Water Treatment Plant. Since the establishment of the Salt Mine Works in the Llobregat basin in 1923, a progressive salinization of the water sources has been recorded. The operation of the Brine Collector, as a public work carried out by Aigües de Barcelona (AGBAR), started in 1989; it enabled a very significant improvement in the quality of the surface water used for drinking-water production.


2018 ◽  
Vol 16 (2) ◽  
pp. 84
Author(s):  
G A Blagodatsky ◽  
A A Bass ◽  
M M Gorokhov ◽  
D S Ponomarev

Работа посвящена системному анализу данных показателей исходной воды при производстве питьевой воды в системе центрального водоснабжения крупного населенного пункта. На сегодняшний день на фоне увеличивающегося негативного антропогенного воздействия на окружающую среду наблюдается ухудшение состояния многих источников питьевого водоснабжения в широком спектре показателей, в частности, таких как органолептические свойства воды. Как следствие, возникает проблема и для питьевой воды. В работе приводится процесс подготовки данных о параметрах исходной воды, забираемой из водохранилища, которые ежемесячно (с 2002 по 2014 год) учитывались на предприятии при дезодорации воды. Приведенные параметры оказывают существенное влияние на органолептические свойства конечной воды. Подготовка данных для анализа проводится методом главных компонент К. Пирсона. Данные, полученные в пространстве R9, переводятся в пространство меньшей размерности R3. Понижение размерности позволяет снизить автокорреляцию между компонентами. Отбор компонент в пространство R3 проводится по правилу Парето. В пространстве R3 методом сферической кластеризации данных «Форель» с постоянным радиусом группировки проводится кластеризация. Приводится пошаговое визуальное представление алгоритма кластеризации в пространстве R3. В работе показано, что в данных показателях качества исходной воды имеются кластеры. Проводится корреляционно-регрессионный анализ данных, представленных в главных компонентах. Строятся регрессионные зависимости показателей органолептических свойств от главных компонент из пространства R3.


2021 ◽  
Vol 761 ◽  
pp. 143867
Author(s):  
Els Belmans ◽  
Lieve Borremans ◽  
Lone Søderkvist Kristensen ◽  
Nicoleta Alina Suciu ◽  
Eva Kerselaers

2017 ◽  
Vol 127 ◽  
pp. 239-248 ◽  
Author(s):  
Karolina Tatari ◽  
Sanin Musovic ◽  
Arda Gülay ◽  
Arnaud Dechesne ◽  
Hans-Jørgen Albrechtsen ◽  
...  

2020 ◽  
Vol 8 ◽  
Author(s):  
Mathilde J. Hedegaard ◽  
Manuela A. Schliemann-Haug ◽  
Nikola Milanovic ◽  
Carson O. Lee ◽  
Rasmus Boe-Hansen ◽  
...  

2001 ◽  
Vol 43 (8) ◽  
pp. 9-18 ◽  
Author(s):  
T. Schofield

Dissolved Air Flotation (DAF) has become increasingly important in the field of potable water treatment, as a preferred option for treating upland and stored lowland waters. This paper outlines the development of dissolved air flotation (DAF) in potable water treatment, the benefits and disadvantages and the recent advances that has taken the process technology from an art to a science.


2021 ◽  
Author(s):  
Carolin Reitter ◽  
Heike Petzoldt ◽  
Andreas Korth ◽  
Felix Schwab ◽  
Claudia Stange ◽  
...  

AbstractWorldwide, surface waters like lakes and reservoirs are one of the major sources for drinking water production, especially in regions with water scarcity. In the last decades, they have undergone significant changes due to climate change. This includes not only an increase of the water temperature but also microbiological changes. In recent years, increased numbers of coliform bacteria have been observed in these surface waters. In our monitoring study we analyzed two drinking water reservoirs (Klingenberg and Kleine Kinzig Reservoir) over a two-year period in 2018 and 2019. We detected high numbers of coliform bacteria up to 2.4 x 104 bacteria per 100 ml during summer months, representing an increase of four orders of magnitude compared to winter. Diversity decreased to one or two species that dominated the entire water body, namely Enterobacter asburiae and Lelliottia spp., depending on the reservoir. Interestingly, the same, very closely related strains have been found in several reservoirs from different regions. Fecal indicator bacteria Escherichia coli and enterococci could only be detected in low concentrations. Furthermore, fecal marker genes were not detected in the reservoir, indicating that high concentrations of coliform bacteria were not due to fecal contamination. Microbial community revealed Frankiales and Burkholderiales as dominant orders. Enterobacterales, however, only had a frequency of 0.04% within the microbial community, which is not significantly affected by the extreme change in coliform bacteria number. Redundancy analysis revealed water temperature, oxygen as well as nutrients and metals (phosphate, manganese) as factors affecting the dominant species. We conclude that this sudden increase of coliform bacteria is an autochthonic process that can be considered as a mass proliferation or “coliform bloom” within the reservoir. It is correlated to higher water temperatures in summer and is therefore expected to occur more frequently in the near future, challenging drinking water production.HighlightsColiform bacteria proliferate in drinking water reservoirs to values above 104 per 100 mlThe genera Lelliottia and Enterobacter can form these “coliform blooms”Mass proliferation is an autochthonic process, not related to fecal contaminationsIt is related to water temperature and appears mainly in summerIt is expected to occur more often in future due to climate changeGraphical abstract


Sign in / Sign up

Export Citation Format

Share Document