Use of a point-of-care portable blood analyzer for evaluation of blood gas analytes and select physiologic parameters in the American flamingo (Phoenicopterus ruber)

2015 ◽  
Vol 25 (1) ◽  
pp. 161-164 ◽  
Author(s):  
S. Gardhouse ◽  
D. Eshar
2020 ◽  
Author(s):  
Josep del Hoyo ◽  
Peter F. D. Boesman ◽  
Ernest Garcia

Animals ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. 203
Author(s):  
María Gemma Millán de la Blanca ◽  
Eva Martínez-Nevado ◽  
Cristina Castaño ◽  
Juncal García ◽  
Berenice Bernal ◽  
...  

The American flamingo is a useful model for the development of successful semen cryopreservation procedures to be applied to threatened related species from the family Phoenicopteridae, and to permit genetic material banking. Current study sought to develop effective sperm cryopreservation protocols through examining the influences of two permeating cryoprotectants and the seminal plasma removal. During two consecutive years (April), semen samples were collected and frozen from American flamingos. In the first year, the effect of two permeating cryoprotectants, DMA (dimethylacetamide) (6%) or Me2SO (dimethylsulphoxide) (8%), on frozen–thawed sperm variables were compared in 21 males. No differences were seen between DMA and Me2SO for sperm motility, sperm viability, and DNA fragmentation after thawing. In the second year, the role of seminal plasma on sperm cryoresistance was investigated in 31 flamingos. Sperm samples were cryopreserved with and without seminal plasma, using Me2SO (8%) as a cryoprotectant. The results showed that samples with seminal plasma had higher values than samples without seminal plasma for the following sperm variables: Straight line velocity (22.40 µm/s vs. 16.64 µm/s), wobble (75.83% vs. 69.40%), (p < 0.05), linearity (62.73% vs. 52.01%) and straightness (82.38% vs. 73.79%) (p < 0.01); but acrosome integrity was lower (55.56% vs. 66.88%) (p < 0.05). The cryoresistance ratio (CR) was greater in samples frozen with seminal plasma than without seminal plasma for CR-progressive motility (138.72 vs. 54.59), CR-curvilinear velocity (105.98 vs. 89.32), CR-straight line velocity (152.77 vs. 112.58), CR-average path velocity (122.48 vs. 98.12), CR-wobble (111.75 vs. 102.04) (p < 0.05), CR-linearity (139.41 vs. 113.18), and CR-straightness (124.02 vs. 109.97) (p < 0.01). This research demonstrated that there were not differences between Me2SO and DMA to successful freezing sperm of flamingos; seminal plasma removal did not provide a benefit for sperm cryopreservation.


1994 ◽  
Vol 40 (1) ◽  
pp. 124-129 ◽  
Author(s):  
R J Wong ◽  
J J Mahoney ◽  
J A Harvey ◽  
A L Van Kessel

Abstract We evaluated a new portable instrument, the PPG StatPal II pH and Blood Gas Analysis System, designed for "point-of-care" measurements of blood gases and pH. Inaccuracy (% of target value) and imprecision (CV%) were assessed by blood tonometry and comparison with a Corning 178. Within-day results for PCO2 inaccuracy and imprecision ranged from 98.2% to 102.9% and 3.3% to 3.9%, respectively; for PO2, these were 95.5% to 102.3% and 2.3% to 3.0%, respectively. Between-day results for PCO2 inaccuracy and imprecision ranged from 99.2% to 99.3% and from 2.9% to 3.2%, respectively; for PO2, the ranges were 96.2% to 98.2% and 2.6% to 3.0%, respectively. Two PCO2 outliers (in 645 samples = 0.3%) were observed. In general, tonometry recovery, measurement stability, and pH bias results for the StatPal II and Corning 178 were comparable. We conclude that the StatPal II performs within acceptable ranges of inaccuracy and imprecision.


Anaesthesia ◽  
2016 ◽  
Vol 71 (9) ◽  
pp. 1044-1052 ◽  
Author(s):  
L. F. Miles ◽  
K. Giraud ◽  
R. Ferris ◽  
A. A. Klein ◽  
G. C. Martinez ◽  
...  
Keyword(s):  

PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0244117
Author(s):  
Leopoldo Torres-Cristiani ◽  
Salima Machkour-M’Rabet ◽  
Sophie Calmé ◽  
Holger Weissenberger ◽  
Griselda Escalona-Segura

The American Flamingo, Phoenicopterus ruber, is a charismatic bird distributed throughout the Caribbean, North and South America. Its wide distribution, the complexity of international monitoring due to its capacity for long-distance flying, and a focus mostly on local populations, make it difficult to understand the dynamics between sites. Here, we took advantage of the citizen eBird science project to present a global perspective on the distribution of the American Flamingo, and identify the potentially most important countries for breeding. We obtained 16,930 records for the Americas from the 1960s until October 2018, of which 9,283 could be used for our objectives. The eBird database indicated a considerable increase in the total number of records over the last decade (2010s), probably reflecting an increase in tourism facilities, research investment, technological advancement, interest in conservation, and the worldwide availability of eBird. We also observed a range extension in the Gulf of Mexico in the United States and a significant recolonization in the Florida Peninsula. The apparent range extension to the South is more likely to be linked to biases in the data; for example, in any given country the number of records might reflect either reporting efforts or actual numbers. eBird data confirmed that six countries host the main breeding colonies (Bahamas, Bonaire, Cuba, Ecuador, Mexico, and Venezuela). We suggest three additional countries as potential breeding areas for the species (Colombia, Curaçao, Turks and Caicos Islands) for which more field observations are necessary to support this possibility. This global appraisal of the distribution of the American Flamingo using citizen science data provides valuable information for national and international management and conservation programs such as the need to verify the species breeding status in areas where it appears to be expanding its distribution.


2020 ◽  
Vol 4 (2) ◽  
pp. 27
Author(s):  
Ernest Philani Buthelezi ◽  
Edwin Rampota ◽  
Matumi Mphogo ◽  
Florence Marule ◽  
Donald Moshen Tanyanyiwa

Author(s):  
Lukasz Krzych ◽  
Olga Wojnarowicz ◽  
Paweł Ignacy ◽  
Julia Dorniak

Introduction. Reliable results of an arterial blood gas (ABG) analysis are crucial for the implementation of appropriate diagnostics and therapy. We aimed to investigate the differences (Δ) between ABG parameters obtained from point-of-care testing (POCT) and central laboratory (CL) measurements, taking into account the turnaround time (TAT). Materials and methods. A number of 208 paired samples were collected from 54 intensive care unit (ICU) patients. Analyses were performed using Siemens RAPIDPoint 500 Blood Gas System on the samples just after blood retrieval at the ICU and after delivery to the CL. Results. The median TAT was 56 minutes (IQR 39-74). Differences were found for all ABG parameters. Median Δs for acid-base balance ere: ΔpH=0.006 (IQR –0.0070–0.0195), ΔBEef=–0.9 (IQR –2.0–0.4) and HCO3–act=–1.05 (IQR –2.25–0.35). For ventilatory parameters they were: ΔpO2=–8.3 mmHg (IQR –20.9–0.8) and ΔpCO2=–2.2 mmHg (IQR –4.2––0.4). For electrolytes balance the differences were: ΔNa+=1.55 mM/L (IQR 0.10–2.85), ΔK+=–0.120 mM/L (IQR –0.295–0.135) and ΔCl–=1.0 mM/L (IQR –1.0–3.0). Although the Δs might have caused misdiagnosis in 51 samples, Bland-Altman analysis revealed that only for pO2 the difference was of clinical significance (mean: –10.1 mmHg, ±1.96SD –58.5; +38.3). There was an important correlation between TAT and ΔpH (R=0.45, p<0.01) with the safest time delay for proper assessment being less than 39 minutes. Conclusions. Differences between POCT and CL results in ABG analysis may be clinically important and cause misdiagnosis, especially for pO2. POCT should be advised for ABG analysis due to the impact of TAT, which seems to be the most important for the analysis of pH.


2020 ◽  
Vol 8 (1) ◽  
Author(s):  
Carlos A Valle ◽  
Catalina Ulloa ◽  
Cristina Regalado ◽  
Juan-Pablo Muñoz-Pérez ◽  
Juan Garcia ◽  
...  

Abstract The swallow-tailed gull, Creagrus furcatus, is a seabird endemic to the Galápagos archipelago. In general health, blood chemistry and haematology, parameters have not been published for this species. Blood analyses were run on samples drawn from 58 clinically healthy swallow-tailed gulls captured at Islote Pitt on San Cristóbal Island in July 2016 (28) and South Plaza Island in June 2017 (30). A point of care blood analyzer (iSTAT) was used in the field to obtain results for HCO3−, pH, pCO2, pO2, TCO2, anion gap, chloride, creatinine, glucose, haematocrit, haemoglobin, ionized calcium, potassium, sodium and urea nitrogen. A portable Lactate Plus™ analyzer was used to measure lactate. The baseline data reported is valuable for comparisons amongst different populations in the archipelago and to detect changes in health status of Galápagos swallow-tailed gulls.


Sign in / Sign up

Export Citation Format

Share Document