scholarly journals Variplex™ test system fails to reliably detect SARS-CoV-2 directly from respiratory samples without RNA extraction

2020 ◽  
Vol 39 (12) ◽  
pp. 2373-2377 ◽  
Author(s):  
Florian Eckel ◽  
Franziska Küsters ◽  
Bernhard Drossel ◽  
Markus Konert ◽  
Hans Mattes ◽  
...  

AbstractDiagnosis of COVID is performed by PCR methods, but their capacity is limited by the requirement of high-level facilities and instruments. The loop-mediated isothermal amplification (LAMP) method has been utilized for the detection of isolated virus-specific RNA. Preliminary data suggest the possibility of isothermal amplification directly from respiratory samples without RNA extraction. All patients admitted to our hospital were screened for SARS-CoV-2 by routine. Respiratory samples were tested by variplex system based on LAMP method directly without RNA extraction and by PCR. Primary endpoint was the false-negative rate of variplex test compared with PCR as gold standard. In 109 patients variplex test and PCR assay were performed simultaneously. Median age was 80 years and male/female ratio was 40/60%. The prevalence of PCR-confirmed COVID diagnosis was 43.1%. Variplex test was positive in 13.8%. False-negative rate of variplex test compared with PCR was 83.0%. The potential of LAMP technology using isolated RNA has been demonstrated impressively by others, and excellent sensitivity and specificity of detecting SARS-CoV-2 has been reported. However, without RNA extraction, the variplex test system failed to reliably detect SARS-CoV-2 directly in respiratory samples.

2020 ◽  
Author(s):  
Florian Eckel ◽  
Franziska Küsters ◽  
Bernhard Drossel ◽  
Markus Konert ◽  
Hans Mattes ◽  
...  

Abstract Diagnosis of COVID is performed by PCR methods, but their capacitiy is limited by the requirement of high-level facilities and instruments. The loop-mediated isothermal amplification (LAMP) method has been utilized for the detection of isolated virus-specific RNA. Preliminary data suggest the possibility of isothermal amplification directly from respiratory samples without RNA extraction.All patients admitted to our hospital were screened for SARS-CoV-2 by routine. Respiratory samples were tested by variplex system based on LAMP method directly without RNA extraction and by PCR. Confirmation or exclusion of clinical COVID diagnosis was based on history, examination and findings. Primary endpoint was the false negative rate of variplex test compared to PCR.A total of 153 patients were included in the study. Median age was 79 years and male/female ratio was 45%/55%. Prevalence of clinical COVID diagnosis was 61.4%. Variplex test and PCR assay was positive in 15.0% and 45.5%, respectively. In 109 patients variplex test and PCR assay were performed simultaneously. False negative rate of variplex test compared to PCR was 83.0%.The potential of LAMP-technology using isolated RNA has been demonstrated impressively by others and excellent sensitivity and specivity of detecting SARS-CoV-2 has been reported. However, without RNA extraction the variplex test system failed to reliable detect SARS-CoV-2 directly in respiratory samples.


2011 ◽  
Vol 21 (9) ◽  
pp. 1679-1683 ◽  
Author(s):  
Tessa A. Ennik ◽  
David G. Allen ◽  
Ruud L.M. Bekkers ◽  
Simon E. Hyde ◽  
Peter T. Grant

BackgroundThere is a growing interest to apply the sentinel node (SN) procedure in the treatment of vulvar cancer. Previous vulvar surgery might disrupt lymphatic patterns and thereby decrease SN detection rates, lengthen scintigraphic appearance time (SAT), and increase SN false-negative rate. The aims of this study were to evaluate the SN detection rates at the Mercy Hospital for Women in Melbourne and to investigate whether previous vulvar surgery affects SN detection rates, SAT, and SN false-negative rate.MethodsData on all patients with vulvar cancer who underwent an SN procedure (blue dye, technetium, or combined technique) from November 2000 to July 2010 were retrospectively collected.ResultsSixty-five SN procedures were performed. Overall detection rate was 94% per person and 80% per groin. Detection rates in the group of patients who underwent previous excision of the primary tumor were not lower compared with the group without previous surgery or with just an incisional biopsy. There was no statistical significant difference in SAT between the previous excision group and the other patients. None of the patients with a false-negative SN had undergone previous excision.ConclusionsResults indicate that previous excision of a primary vulvar malignancy does not decrease SN detection rates or increase SN false-negative rate. Therefore, the SN procedure appears to be a reliable technique in patients who have previously undergone vulvar surgery. Previous excision did not significantly lengthen SAT, but the sample size in this subgroup analysis was small.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Katherine F. Jarvis ◽  
Joshua B. Kelley

AbstractColleges and other organizations are considering testing plans to return to operation as the COVID-19 pandemic continues. Pre-symptomatic spread and high false negative rates for testing may make it difficult to stop viral spread. Here, we develop a stochastic agent-based model of COVID-19 in a university sized population, considering the dynamics of both viral load and false negative rate of tests on the ability of testing to combat viral spread. Reported dynamics of SARS-CoV-2 can lead to an apparent false negative rate from ~ 17 to ~ 48%. Nonuniform distributions of viral load and false negative rate lead to higher requirements for frequency and fraction of population tested in order to bring the apparent Reproduction number (Rt) below 1. Thus, it is important to consider non-uniform dynamics of viral spread and false negative rate in order to model effective testing plans.


2021 ◽  
Vol 106 ◽  
pp. 106582
Author(s):  
Alex Niu ◽  
Bo Ning ◽  
Francisco Socola ◽  
Hana Safah ◽  
Tim Reynolds ◽  
...  

2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
E Johnston ◽  
S Taylor ◽  
F Bannon ◽  
S McAllister

Abstract Introduction and Aims The aim of this systematic review is to provide an up-to-date evaluation of the role and test performance of sentinel lymph node biopsy (SLNB) in the head and neck. Method This review follows the PRISMA guidelines. Database searches for MEDLINE and EMBASE were constructed to retrieve human studies published between 1st January 2010 and 1st July 2020 assessing the role and accuracy of sentinel lymph node biopsy in cutaneous malignant melanoma of the head and neck. Articles were independently screened by two reviewers and critically appraised using the MINORS criteria. The primary outcomes consisted of the sentinel node identification rate and test-performance measures, including the false-negative rate and the posttest probability negative. Results A total of 27 studies, including 4688 patients, met the eligibility criteria. Statistical analysis produced weighted summary estimates for the sentinel node identification rate of 97.3% (95% CI, 95.9% to 98.6%), the false-negative rate of 21.3% (95% CI, 17.0% to 25.4%) and the posttest probability negative of 4.8% (95% CI, 3.9% to 5.8%). Discussion Sentinel lymph node biopsy is accurate and feasible in the head and neck. Despite technical improvements in localisation techniques, the false negative rate remains disproportionately higher than for melanoma in other anatomical sites.


2021 ◽  
Vol 10 (4) ◽  
pp. 602
Author(s):  
Antoine Tardieu ◽  
Lobna Ouldamer ◽  
François Margueritte ◽  
Lauranne Rossard ◽  
Aymeline Lacorre ◽  
...  

The objective of our study is to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET-CT) for the assessment of lymph node involvement in advanced epithelial ovarian, fallopian tubal or peritoneal cancer (EOC). This was a retrospective, bicentric study. We included all patients over 18 years of age with a histological diagnosis of advanced EOC who had undergone PET-CT at the time of diagnosis or prior to cytoreduction surgery with pelvic or para-aortic lymphadenectomy. We included 145 patients with primary advanced EOC. The performance of PET-CT was calculated from the data of 63 patients. The sensitivity of PET-CT for preoperative lymph node evaluation was 26.7%, specificity was 90.9%, PPV was 72.7%, and NPV was 57.7%. The accuracy rate was 60.3%, and the false-negative rate was 34.9%. In the case of primary cytoreduction (n = 16), the sensitivity of PET-CT was 50%, specificity was 87.5%, PPV was 80%, and NPV was 63.6%. The accuracy rate was 68.8%, and the false negative rate was 25%. After neoadjuvant chemotherapy (n = 47), the sensitivity of PET-CT was 18.2%, specificity was 92%, PPV was 66.7%, and NPV was 56.1%. The accuracy rate was 57.5%, and the false negative rate was 38.3%. Due to its high specificity, the performance of a preoperative PET-CT scan could contribute to the de-escalation and reduction of lymphadenectomy in the surgical management of advanced EOC in a significant number of patients free of lymph node metastases.


2019 ◽  
Vol 58 (6) ◽  
pp. 671-676
Author(s):  
Amy M. West ◽  
Pierre A. d’Hemecourt ◽  
Olivia J. Bono ◽  
Lyle J. Micheli ◽  
Dai Sugimoto

The objective of this study was to determine diagnostic accuracy of magnetic resonance imaging (MRI) and computed tomography (CT) scans in young athletes diagnosed with spondylolysis. A cross-sectional study was used. Twenty-two young athletes (14.7 ± 1.5 years) were diagnosed as spondylolysis based on a single-photon emission CT. Following the diagnosis, participants underwent MRI and CT scan imaging tests on the same day. The sensitivity and false-negative rate of the MRI and CT scans were analyzed. MRI test confirmed 13 (+) and 9 (−) results while CT test showed 17 (+) and 5 (−) results. The sensitivity and false-negative rate of MRI were, respectively, 59.1% (95% confidence interval [CI] = 36.7% to 78.5%) and 40.9% (95% CI = 21.5% to 63.3%). Furthermore, the sensitivity and false-negative rate of CT scan were 77.3% (95% CI = 54.2% to 91.3%) and 22.7% (95% CI = 0.09% to 45.8%). Our results indicated that CT scan is a more accurate imaging modality to diagnose spondylolysis compared with MRI in young athletes.


2006 ◽  
Vol 82 (4) ◽  
pp. 1185-1190 ◽  
Author(s):  
Anthony Lemaire ◽  
Ivana Nikolic ◽  
Thomas Petersen ◽  
Jack C. Haney ◽  
Eric M. Toloza ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document