027 Diagnostic Accuracy of a Single Serum Testosterone Measurement: The False Negative Rate

2016 ◽  
Vol 13 (5) ◽  
pp. S13
Author(s):  
X. Ni ◽  
D. Muram
Neurology ◽  
2017 ◽  
Vol 88 (15) ◽  
pp. 1468-1477 ◽  
Author(s):  
Alexander Andrea Tarnutzer ◽  
Seung-Han Lee ◽  
Karen A. Robinson ◽  
Zheyu Wang ◽  
Jonathan A. Edlow ◽  
...  

Objective:With the emergency department (ED) being a high-risk site for diagnostic errors, we sought to estimate ED diagnostic accuracy for identifying acute cerebrovascular events.Methods:MEDLINE and Embase were searched for studies (1995–2016) reporting ED diagnostic accuracy for ischemic stroke, TIA, or subarachnoid hemorrhage (SAH). Two independent reviewers determined inclusion. We identified 1,693 unique citations, examined 214 full articles, and analyzed 23 studies. Studies were rated on risk of bias (QUADAS-2). Diagnostic data were extracted. We prospectively defined clinical presentation subgroups to compare odds of misdiagnosis.Results:Included studies reported on 15,721 patients. Studies were at low risk of bias. Overall sensitivity (91.3% [95% confidence interval (CI) 90.7–92.0]) and specificity (92.7% [91.7–93.7]) for a cerebrovascular etiology was high, but there was significant variation based on clinical presentation. Misdiagnosis was more frequent among subgroups with milder (SAH with normal vs abnormal mental state; false-negative rate 23.8% vs 4.2%, odds ratio [OR] 7.03 [4.80–10.31]), nonspecific (dizziness vs motor findings; false-negative rate 39.4% vs 4.4%, OR 14.22 [9.76–20.74]), or transient (TIA vs ischemic stroke; false discovery rate 59.7% vs 11.7%, OR 11.21 [6.66–18.89]) symptoms.Conclusions:Roughly 9% of cerebrovascular events are missed at initial ED presentation. Risk of misdiagnosis is much greater when presenting neurologic complaints are mild, nonspecific, or transient (range 24%–60%). This difference suggests that many misdiagnoses relate to symptom-specific factors. Future research should emphasize studying causes and designing error-reduction strategies in symptom-specific subgroups at greatest risk of misdiagnosis.


1994 ◽  
Vol 73 (6) ◽  
pp. 377-380 ◽  
Author(s):  
Cliff A. Megerian ◽  
Anthony J. Maniglia

During the years 1980 through 1990, 247 patients underwent parotidectomy at our institution for the removal of primary parotid lesions. Charts were reviewed in an effort to document the distribution of pathology in patients undergoing parotidectomy and the histopathology from each case was organized and tallied by virtue of the final specific diagnoses. An additional goal of this study was to evaluate the efficacy of pre-operative fine-needle aspiration biopsy (FNAB) and frozen section pathology in accurately predicting final histopathology. In our series, 86.7% of lesions were found to be benign and 13.3% were malignant in nature. When compared to final pathologic findings, FNAB yielded a diagnostic accuracy rate of 89.3% with a 2.1% false negative rate with regards to pre-operative detection of malignancy. Frozen section biopsy was found to have a diagnostic accuracy of 94.1% and also demonstrated a 2.1% false-negative rate. We believe these studies are indeed complementary to each other, as reflected in the 96.2% diagnostic accuracy achieved with a combination of FNAB and frozen section biopsy information. This report will review the patterns of misdiagnosis for each modality of diagnostic testing and present the parotid histopathology found over a 10-year period.


2021 ◽  
Vol 5 (Supplement_1) ◽  
pp. A97-A98
Author(s):  
Malavika Suresh ◽  
Lucinda Gruber ◽  
Irina Bancos

Abstract Background: Evaluation for adrenal insufficiency (AI) includes dynamic testing that is cumbersome, expensive, and may not always be accessible. Our objective was to evaluate the diagnostic accuracy of dehydroepiandrosterone sulfate (DHEAS) in diagnosing AI. Methods: This is a single-center retrospective study of patients evaluated for AI between July 10th, 2012 to January 7th, 2020 who underwent Cosyntropin stimulation testing (CST) or Insulin tolerance test (ITT), and had baseline measurement of DHEAS. Diagnosis of adrenal insufficiency was based on peak cortisol of <18 ug/dL during either CST or ITT. Results: We identified 491 patients (379 [77.2%] women, median age 42 years [range 18–84]) who met inclusion criteria. Primary adrenal insufficiency (PAI) was diagnosed in 16 (3%) patients, secondary adrenal insufficiency (SAI) was diagnosed in 211 (43%) patients, and AI was excluded in 264 (54%) patients. CST was performed in 478 (97%) patients, ITT was done in 45 (9%) patients, with 32 patients having both CST and ITT performed. Using a peak cortisol of <18 mcg/dl during CST to diagnose AI, ROC analysis of DHEAS demonstrated an area under the curve of 0.79, p<0.0001. A DHEAS cutoff of 100 mcg/dL excluded AI with a sensitivity of 93%, specificity of 41%, and a false negative rate of 3%. A DHEAS cut-off of 25 mcg/dl diagnosed AI with a false positive rate of 9% (Sensitivity 57% and specificity 85%). Notably, of 32 patients who had both CST and ITT performed, the diagnosis of AI was concordant in only 5 patients, while additional 27 patients had discordant results (26 were diagnosed with SAI based on ITT, but with a normal CST, and 1 patient was diagnosed with AI on CST but not on ITT). When excluding the 27 patients with discordant results, the overall performance of DHEAS in diagnosis of AI based on CST has not changed. Conclusion: DHEAS is a valuable baseline diagnostic test for AI. DHEAS >100 mcg/dl predicts a normal response during CST with a false negative rate of 3%, while DHEAS <25 mcg/dl is reflective of underlying adrenal insufficiency and predicts an abnormal CST with a false positive rate of 9%. In these situations, CST can be avoided.


2011 ◽  
Vol 21 (9) ◽  
pp. 1679-1683 ◽  
Author(s):  
Tessa A. Ennik ◽  
David G. Allen ◽  
Ruud L.M. Bekkers ◽  
Simon E. Hyde ◽  
Peter T. Grant

BackgroundThere is a growing interest to apply the sentinel node (SN) procedure in the treatment of vulvar cancer. Previous vulvar surgery might disrupt lymphatic patterns and thereby decrease SN detection rates, lengthen scintigraphic appearance time (SAT), and increase SN false-negative rate. The aims of this study were to evaluate the SN detection rates at the Mercy Hospital for Women in Melbourne and to investigate whether previous vulvar surgery affects SN detection rates, SAT, and SN false-negative rate.MethodsData on all patients with vulvar cancer who underwent an SN procedure (blue dye, technetium, or combined technique) from November 2000 to July 2010 were retrospectively collected.ResultsSixty-five SN procedures were performed. Overall detection rate was 94% per person and 80% per groin. Detection rates in the group of patients who underwent previous excision of the primary tumor were not lower compared with the group without previous surgery or with just an incisional biopsy. There was no statistical significant difference in SAT between the previous excision group and the other patients. None of the patients with a false-negative SN had undergone previous excision.ConclusionsResults indicate that previous excision of a primary vulvar malignancy does not decrease SN detection rates or increase SN false-negative rate. Therefore, the SN procedure appears to be a reliable technique in patients who have previously undergone vulvar surgery. Previous excision did not significantly lengthen SAT, but the sample size in this subgroup analysis was small.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Katherine F. Jarvis ◽  
Joshua B. Kelley

AbstractColleges and other organizations are considering testing plans to return to operation as the COVID-19 pandemic continues. Pre-symptomatic spread and high false negative rates for testing may make it difficult to stop viral spread. Here, we develop a stochastic agent-based model of COVID-19 in a university sized population, considering the dynamics of both viral load and false negative rate of tests on the ability of testing to combat viral spread. Reported dynamics of SARS-CoV-2 can lead to an apparent false negative rate from ~ 17 to ~ 48%. Nonuniform distributions of viral load and false negative rate lead to higher requirements for frequency and fraction of population tested in order to bring the apparent Reproduction number (Rt) below 1. Thus, it is important to consider non-uniform dynamics of viral spread and false negative rate in order to model effective testing plans.


2021 ◽  
Vol 106 ◽  
pp. 106582
Author(s):  
Alex Niu ◽  
Bo Ning ◽  
Francisco Socola ◽  
Hana Safah ◽  
Tim Reynolds ◽  
...  

2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
E Johnston ◽  
S Taylor ◽  
F Bannon ◽  
S McAllister

Abstract Introduction and Aims The aim of this systematic review is to provide an up-to-date evaluation of the role and test performance of sentinel lymph node biopsy (SLNB) in the head and neck. Method This review follows the PRISMA guidelines. Database searches for MEDLINE and EMBASE were constructed to retrieve human studies published between 1st January 2010 and 1st July 2020 assessing the role and accuracy of sentinel lymph node biopsy in cutaneous malignant melanoma of the head and neck. Articles were independently screened by two reviewers and critically appraised using the MINORS criteria. The primary outcomes consisted of the sentinel node identification rate and test-performance measures, including the false-negative rate and the posttest probability negative. Results A total of 27 studies, including 4688 patients, met the eligibility criteria. Statistical analysis produced weighted summary estimates for the sentinel node identification rate of 97.3% (95% CI, 95.9% to 98.6%), the false-negative rate of 21.3% (95% CI, 17.0% to 25.4%) and the posttest probability negative of 4.8% (95% CI, 3.9% to 5.8%). Discussion Sentinel lymph node biopsy is accurate and feasible in the head and neck. Despite technical improvements in localisation techniques, the false negative rate remains disproportionately higher than for melanoma in other anatomical sites.


2021 ◽  
Vol 10 (4) ◽  
pp. 602
Author(s):  
Antoine Tardieu ◽  
Lobna Ouldamer ◽  
François Margueritte ◽  
Lauranne Rossard ◽  
Aymeline Lacorre ◽  
...  

The objective of our study is to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET-CT) for the assessment of lymph node involvement in advanced epithelial ovarian, fallopian tubal or peritoneal cancer (EOC). This was a retrospective, bicentric study. We included all patients over 18 years of age with a histological diagnosis of advanced EOC who had undergone PET-CT at the time of diagnosis or prior to cytoreduction surgery with pelvic or para-aortic lymphadenectomy. We included 145 patients with primary advanced EOC. The performance of PET-CT was calculated from the data of 63 patients. The sensitivity of PET-CT for preoperative lymph node evaluation was 26.7%, specificity was 90.9%, PPV was 72.7%, and NPV was 57.7%. The accuracy rate was 60.3%, and the false-negative rate was 34.9%. In the case of primary cytoreduction (n = 16), the sensitivity of PET-CT was 50%, specificity was 87.5%, PPV was 80%, and NPV was 63.6%. The accuracy rate was 68.8%, and the false negative rate was 25%. After neoadjuvant chemotherapy (n = 47), the sensitivity of PET-CT was 18.2%, specificity was 92%, PPV was 66.7%, and NPV was 56.1%. The accuracy rate was 57.5%, and the false negative rate was 38.3%. Due to its high specificity, the performance of a preoperative PET-CT scan could contribute to the de-escalation and reduction of lymphadenectomy in the surgical management of advanced EOC in a significant number of patients free of lymph node metastases.


2019 ◽  
Vol 58 (6) ◽  
pp. 671-676
Author(s):  
Amy M. West ◽  
Pierre A. d’Hemecourt ◽  
Olivia J. Bono ◽  
Lyle J. Micheli ◽  
Dai Sugimoto

The objective of this study was to determine diagnostic accuracy of magnetic resonance imaging (MRI) and computed tomography (CT) scans in young athletes diagnosed with spondylolysis. A cross-sectional study was used. Twenty-two young athletes (14.7 ± 1.5 years) were diagnosed as spondylolysis based on a single-photon emission CT. Following the diagnosis, participants underwent MRI and CT scan imaging tests on the same day. The sensitivity and false-negative rate of the MRI and CT scans were analyzed. MRI test confirmed 13 (+) and 9 (−) results while CT test showed 17 (+) and 5 (−) results. The sensitivity and false-negative rate of MRI were, respectively, 59.1% (95% confidence interval [CI] = 36.7% to 78.5%) and 40.9% (95% CI = 21.5% to 63.3%). Furthermore, the sensitivity and false-negative rate of CT scan were 77.3% (95% CI = 54.2% to 91.3%) and 22.7% (95% CI = 0.09% to 45.8%). Our results indicated that CT scan is a more accurate imaging modality to diagnose spondylolysis compared with MRI in young athletes.


Sign in / Sign up

Export Citation Format

Share Document