scholarly journals Vascular 3D Printing with a Novel Biological Tissue Mimicking Resin for Patient-Specific Procedure Simulations in Interventional Radiology: a Feasibility Study

Author(s):  
R. Kaufmann ◽  
C. J. Zech ◽  
M. Takes ◽  
P. Brantner ◽  
F. Thieringer ◽  
...  

AbstractThree-dimensional (3D) printing of vascular structures is of special interest for procedure simulations in Interventional Radiology, but remains due to the complexity of the vascular system and the lack of biological tissue mimicking 3D printing materials a technical challenge. In this study, the technical feasibility, accuracy, and usability of a recently introduced silicone-like resin were evaluated for endovascular procedure simulations and technically compared to a commonly used standard clear resin. Fifty-four vascular models based on twenty-seven consecutive embolization cases were fabricated from preinterventional CT scans and each model was checked for printing success and accuracy by CT-scanning and digital comparison to its original CT data. Median deltas (Δ) of luminal diameters were 0.35 mm for clear and 0.32 mm for flexible resin (216 measurements in total) with no significant differences (p > 0.05). Printing success was 85.2% for standard clear and 81.5% for the novel flexible resin. In conclusion, vascular 3D printing with silicone-like flexible resin was technically feasible and highly accurate. This is the first and largest consecutive case series of 3D-printed embolizations with a novel biological tissue mimicking material and is a promising next step in patient-specific procedure simulations in Interventional Radiology.

Author(s):  
Brett G. Darrow ◽  
Kyle A. Snowdon ◽  
Adrien Hespel

Abstract Objective The aim of this study was to evaluate the accuracy of patient-specific three-dimensional printed drill guides (3D-PDG) for the placement of a coxofemoral toggle via a minimally invasive approach. Materials and Methods Pre-procedure computed tomography (CT) data of 19 canine cadaveric hips were used to design a cadaver-specific 3D-PDG that conformed to the proximal femur. Femoral and acetabular bone tunnels were drilled through the 3D-PDG, and a coxofemoral toggle pin was placed. The accuracy of tunnel placement was evaluated with post-procedure CT and gross dissection. Results Coxofemoral toggle pins were successfully placed in all dogs. Mean exit point translation at the fovea capitis was 2.5 mm (0.2–7.5) when comparing pre- and post-procedure CT scans. Gross dissection revealed the bone tunnel exited the fovea capitis inside (3/19), partially inside (12/19) and outside of (4/19) the ligament of the head of the femur. Placement of the bone tunnel through the acetabulum was inside (16/19), partially inside (1/19) and outside (2/19) of the acetabular fossa. Small 1 to 2 mm articular cartilage fragments were noted in 10 of 19 specimens. Clinical Significance Three-dimensional printed drill guide designed for coxofemoral toggle pin application is feasible. Errors are attributed to surgical execution and identification of the borders of the fovea capitis on CT data. Future studies should investigate modifications to 3D-PDG design and methods. Three-dimensional printed drill guide for coxofemoral toggle pin placement warrants consideration for use in select clinical cases of traumatic coxofemoral luxation.


Author(s):  
Chia-An Wu ◽  
Andrew Squelch ◽  
Zhonghua Sun

Aim: To determine a printing material that has both elastic property and radiology equivalence close to real aorta for simulation of endovascular stent graft repair of aortic dissection. Background: With the rapid development of three-dimensional (3D) printing technology, a patient-specific 3D printed model is able to help surgeons to make better treatment plan for Type B aortic dissection patients. However, the radiological properties of most 3D printing materials have not been well characterized. This study aims to investigate the appropriate materials for printing human aorta with mechanical and radiological properties similar to the real aortic computed tomography (CT) attenuation. Objective: Quantitative assessment of CT attenuation of different materials used in 3D printed models of aortic dissection for developing patient-specific 3D printed aorta models to simulate type B aortic dissection. Method: A 25-mm length of aorta model was segmented from a patient’s image dataset with diagnosis of type B aortic dissection. Four different elastic commercial 3D printing materials, namely Agilus A40 and A50, Visijet CE-NT A30 and A70 were selected and printed with different hardness. Totally four models were printed out and conducted CT scanned twice on a 192-slice CT scanner using the standard aortic CT angiography protocol, with and without contrast inside the lumen.Five reference points with region of interest (ROI) of 1.77 mm2 were selected at the aortic wall and intimal flap and their Hounsfield units (HU) were measured and compared with the CT attenuation of original CT images. The comparison between the patient’s aorta and models was performed through a paired-sample t-test to determine if there is any significant difference. Result: The mean CT attenuation of aortic wall of the original CT images was 80.7 HU. Analysis of images without using contrast medium showed that the material of Agilus A50 produced the mean CT attenuation of 82.6 HU, which is similar to that of original CT images. The CT attenuation measured at images acquired with other three materials was significantly lower than that of original images (p<0.05). After adding contrast medium, Visijet CE-NT A30 had an average CT attenuation of 90.6 HU, which is close to that of the original images with statistically significant difference (p>0.05). In contrast, the CT attenuation measured at images acquired with other three materials (Agilus A40, A50 and Visiject CE-NT A70) was 129 HU, 135 HU and 129.6 HU, respectively, which is significantly higher than that of original CT images (p<0.05). Conclusion: Both Visijet CE-NT and Agilus have tensile strength and elongation close to real patient’s tissue properties producing similar CT attenuation. Visijet CE-NT A30 is considered the appropriate material for printing aorta to simulate contrast-enhanced CT imaging of type B aortic dissection. Due to lack of body phantom in the experiments, further research with simulation of realistic anatomical body environment should be conducted.


2018 ◽  
Vol 9 (4) ◽  
pp. 454-458 ◽  
Author(s):  
Sarah A. Chen ◽  
Chin Siang Ong ◽  
Nagina Malguria ◽  
Luca A. Vricella ◽  
Juan R. Garcia ◽  
...  

Purpose: Patients with hypoplastic left heart syndrome (HLHS) present a diverse spectrum of aortic arch morphology. Suboptimal geometry of the reconstructed aortic arch may result from inappropriate size and shape of an implanted patch and may be associated with poor outcomes. Meanwhile, advances in diagnostic imaging, computer-aided design, and three-dimensional (3D) printing technology have enabled the creation of 3D models. The purpose of this study is to create a surgical simulation and training model for aortic arch reconstruction. Description: Specialized segmentation software was used to isolate aortic arch anatomy from HLHS computed tomography scan images to create digital 3D models. Three-dimensional modeling software was used to modify the exported segmented models and digitally design printable customized patches that were optimally sized for arch reconstruction. Evaluation: Life-sized models of HLHS aortic arch anatomy and a digitally derived customized patch were 3D printed to allow simulation of surgical suturing and reconstruction. The patient-specific customized patch was successfully used for surgical simulation. Conclusions: Feasibility of digital design and 3D printing of patient-specific patches for aortic arch reconstruction has been demonstrated. The technology facilitates surgical simulation. Surgical training that leads to an understanding of optimal aortic patch geometry is one element that may potentially influence outcomes for patients with HLHS.


2019 ◽  
Vol 13 (3) ◽  
Author(s):  
Gavin A. D'Souza ◽  
Michael D. Taylor ◽  
Rupak K. Banerjee

Assessing hemodynamics in vasculature is important for the development of cardiovascular diagnostic parameters and evaluation of medical devices. Benchtop experiments are a safe and comprehensive preclinical method for testing new diagnostic endpoints and devices within a controlled environment. Recent advances in three-dimensional (3D) printing have enhanced benchtop tests by allowing generation of patient-specific and pathophysiologic conditions. We used 3D printing, coupled with image processing and computer-aided design (CAD), to develop a patient-specific vascular test device from clinical data. The proximal pulmonary artery (PA) tree including the main, left, and right pulmonary arteries, with a stenosis within the left PA was selected as a representative anatomy for developing the vascular test device. Three test devices representing clinically relevant stenosis severities, 90%, 80%, and 70% area stenosis, were evaluated at different cardiac outputs (COs). A mock circulatory loop (MCL) generating pathophysiologic pulmonary pressure and flow was used to evaluate the hemodynamics within the devices. The dimensionless pressure drop–velocity ratio characteristic curves for the three stenosis severities were obtained. At a fixed CO, the dimensionless pressure drop increased nonlinearly with an increase in (a) the velocity ratio for a fixed stenosis severity and (b) the stenosis severity at a specific velocity ratio. The dimensionless pressure drop observed in vivo was similar (within 1%) to that measured in moderate area stenosis of 70% because both flows were viscous dominated. The hemodynamics of the 3D printed test device can be used for evaluating diagnostic endpoints and medical devices in a preclinical setting under realistic conditions.


2016 ◽  
Vol 29 (05) ◽  
pp. 409-415 ◽  
Author(s):  
Peter Strøm ◽  
Boaz Arzi ◽  
Derek Cissell ◽  
Frank Verstraete

SummaryObjective: To describe the clinical features and results of treatment of true ankylosis and pseudoankylosis of the temporomandibular joint in dogs.Methods: This study was a retrospective case series. Ten client-owned dogs that were presented for inability to open the mouth or a severely decreased range of motion of the temporomandibular joint were included. Information on the surgical procedures performed and the perioperative complications were documented. Three-dimensional printing of the skull was performed in four dogs.Results: Two dogs were diagnosed with temporomandibular joint ankylosis and seven dogs with pseudoankylosis. One dog had evidence of combined temporomandibular joint ankylosis and pseudoankylosis. Of the seven dogs with pseudoankylosis, six had an osseous fusion involving the zygomatic arch and mandible. Surgical treatment was performed in nine dogs and a revision surgery was needed in one dog. Follow-up ranged from five months to eight years (mean: 48.6 months). Eight out of nine dogs that were treated surgically regained the ability to open their mouth, but six dogs never regained a fully normal temporomandibular joint range of motion.Clinical significance: Temporomandibular joint ankylosis and pseudoankylosis are uncommon in the dog. Surgical treatment for temporomandibular joint ankylosis or pseudoankylosis in dogs is a successful option and carries a prognosis dependent on patient-specific abnormalities. Computed tomography complemented with three- dimensional printing is valuable for understanding the extent of abnormalities and for preoperative planning.Supplementary material for this paper is available online at http://dx.doi.org/10.3415/VCOT-15-11-0189.


Author(s):  
Tania K. Morimoto ◽  
Michael H. Hsieh ◽  
Allison M. Okamura

Robot-guided sheaths consisting of pre-curved tubes and steerable needles are proposed to provide surgical access to locations deep within the body. In comparison to current minimally invasive surgical robotic instruments, these sheaths are thinner, can move along more highly curved paths, and are potentially less expensive. This paper presents the patient-specific design of the pre-curved tube portion of a robot-guided sheath for access to a kidney stone; such a device could be used for delivery of an endoscope to fragment and remove the stone in a pediatric patient. First, feasible two-dimensional paths were determined considering workspace limitations, including avoidance of the ribs and lung, and minimizing collateral damage to surrounding tissue by leveraging the curvatures of the sheaths. Second, building on prior work in concentric-tube robot mechanics, the mechanical interaction of a two-element sheath was modeled and the resulting kinematics was demonstrated to achieve a feasible path in simulation. In addition, as a first step toward three-dimensional planning, patient-specific CT data was used to reconstruct a three-dimensional model of the area of interest.


2020 ◽  
Author(s):  
Michael Yue-Cheng Chen ◽  
Jacob Skewes ◽  
Ryan Daley ◽  
Maria Ann Woodruff ◽  
Nicholas John Rukin

Abstract BackgroundThree-dimensional (3D) printing is a promising technology but the limitations are often poorly understood. We compare different 3D printingmethods with conventional machining techniques in manufacturing meatal urethral dilators which were recently removed from the Australian market. MethodsA prototype dilator was 3D printed vertically orientated on a low cost fused deposition modelling (FDM) 3D printer in polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS). It was also 3D printed horizontally orientated in ABS on a high-end FDM 3D printer with soluble support material, as well as on a SLS 3D printer in medical nylon. The dilator was also machined in stainless steel using a lathe. All dilators were tested mechanically in a custom rig by hanging calibrated weights from the handle until the dilator snapped. ResultsThe horizontally printed ABS dilator experienced failure at a greater load than the vertically printed PLA and ABS dilators respectively (503g vs 283g vs 163g, p < 0.001). The SLS nylon dilator and machined steel dilator did not fail. The steel dilator is most expensive with a quantity of five at 98 USD each, but this decreases to 30 USD each for a quantity of 1000. In contrast, the cost for the SLS dilator is 33 USD each for five and 27 USD each for 1000. ConclusionsAt the current time 3D printing is not a replacement for conventional manufacturing. 3D printing is best used for patient-specific parts, prototyping or manufacturing complex parts that have additional functionality that cannot otherwise beachieved.


2020 ◽  
Vol 6 (2) ◽  
Author(s):  
Ali Zolfagharian ◽  
Timothy M Gregory ◽  
Mahdi Bodaghi ◽  
Saleh Gharaie ◽  
Pearse Fay

 Despite the frequency of mallet finger injuries, treatment options can often be costly, time-consuming, and ill-fitted. Three-dimensional (3D) printing allows for the production of highly customized and inexpensive splints, which suggests potential efficacy in the prescription of casts for musculoskeletal injuries. This study explores how the use of engineering concepts such as 3D printing and topology optimization (TO) can improve outcomes for patients. 3D printing enables the direct fabrication of the patient-specific complex shapes while utilizing finite element analysis and TO in the design of the splint allowed for the most efficient distribution of material to achieve mechanical requirements while reducing the amount of material used. The reduction in used material leads to significant improvements in weight reduction and heat dissipation, which would improve breathability and less sweating for the patient, greatly increasing comfort for the duration of their recovery.