Measurement of Intraocular Pressure with a Dynamic Tonometer and Presentation of Measurement Results

Author(s):  
M. Yu. Danichenko ◽  
A. A. Mikheev
2021 ◽  
Vol 14 (2) ◽  
pp. 27-35
Author(s):  
O. M. Filippova ◽  
A. M. Bessmertny ◽  
M. N. Kuzin ◽  
S. Yu. Petrov

Purpose: to evaluate the safety and convenience of self-using the intraocular pressure tonometer TVGD-02 at home with no participation of medical professionals. Material and methods. 42 people formed 30 pairs: a patient and an assistant. In 9 pairs, each person played both roles. The participants practiced the technique of transpalpebral measurement of intraocular pressure (IOP) at home, and, as assistants, measured IOP of their partner patients. All subjects were asked to fill in a questionnaire to evaluate the convenience and safety of the tonometer use by a 5-point system. Results. The assistant users, aged 22 to 83 (ave. 59.68 ± 17.20 years) had diverse educational levels. Of the patient users, aged 22 to 82 (ave. 60.64 ± 17.10 years), 82.14 % had ocular pathology, while 35.7 % had glaucoma with concomitant pathology. In 100 % of cases, the participants required no professional assistance to properly prepare the tonometer for operation and perform IOP measurement. The accuracy and reproducibility of measurement results significantly increased with the assistants’ gaining skills of operating the tonometer. On the 1st day, the data obtained in a series of measurements scattered for the control block within 2.07 ± 1.70 [7; 0] mm Hg, while the measured IOP of the patient scattered within 2.89 ± 19.10 [8; 0]. In contrast, on the 5th day, measurement accuracy increased significantly and the scatter dropped to 1.21 ± 0.72 [2; 0] and 0.85 ± 0.69 [2; 0] mm Hg, respectively. The users rated the ease of using the device at different staged from 4.21 ± 0.67 to 5.0 ± 0.0 points. Conclusion. Assisted transpalpebral tonometry with the TVGD-02 tonometer ensures an adequate assessment of IOP in patients at home. The principles of device operation and the technique can be learned and skills can be gained without the participation of medical personnel.


2010 ◽  
Vol 40 (3) ◽  
pp. 156-159 ◽  
Author(s):  
Yıldırım Bayezıt Şakalar ◽  
Selahattin Uğur Keklikçi ◽  
Selahattin Balsak ◽  
Eyyüp Doğan ◽  
Kaan Ünlü

2017 ◽  
Vol 2017 ◽  
pp. 1-9
Author(s):  
Robert Koprowski ◽  
Lei Tian

Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05). The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05). When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3). Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.


2011 ◽  
Vol 42 (S 01) ◽  
Author(s):  
D Tibussek ◽  
F Distelmaier ◽  
S Kummer ◽  
E Mayatepek

2020 ◽  
pp. 3-8
Author(s):  
L.F. Vitushkin ◽  
F.F. Karpeshin ◽  
E.P. Krivtsov ◽  
P.P. Krolitsky ◽  
V.V. Nalivaev ◽  
...  

The State special primary acceleration measurement standard for gravimetry (GET 190-2019), its composition, principle of operation and basic metrological characteristics are presented. This standard is on the upper level of reference for free-fall acceleration measurements. Its accuracy and reliability were improved as a result of optimisation of the adjustment procedures for measurement systems and its integration within the upgraded systems, units and modern hardware components. A special attention was given to adjusting the corrections applied to measurement results with respect to procedural, physical and technical limitations. The used investigation methods made it possibled to confirm the measurement range of GET 190-2019 and to determine the contributions of main sources of errors and the total value of these errors. The measurement characteristics and GET 90-2019 were confirmed by the results obtained from measurements of the absolute value of the free fall acceleration at the gravimetrical site “Lomonosov-1” and by their collation with the data of different dates obtained from measurements by high-precision foreign and domestic gravimeters. Topicality of such measurements ensues from the requirements to handle the applied problems that need data on parameters of the Earth gravitational field, to be adequately faced. Geophysics and navigation are the main fields of application for high-precision measurements in this field.


2020 ◽  
pp. 66-72
Author(s):  
Irina A. Piterskikh ◽  
Svetlana V. Vikhrova ◽  
Nina G. Kovaleva ◽  
Tatyana O. Barynskaya

Certified reference materials (CRM) composed of propyl (11383-2019) and isopropyl (11384-2019) alcohols solutions were created for validation of measurement procedures and control of measurement errors of measurement results of mass concentrations of toxic substances (alcohol) in biological objects (urine, blood) and water. Two ways of establishing the value of the certified characteristic – mass consentration of propanol-1 or propanol-2 have been studied. The results obtained by the preparation procedure and comparison with the standard are the same within the margin of error.


2020 ◽  
pp. 64-70
Author(s):  
Mariya Y. Medvedevskikh ◽  
Anna S. Sergeeva

The article raises the problem of ensuring metrological traceability of the measurement results of indicators of quality and nutritional value for food products and food raw materials: water (moisture), nitrogen (protein, crude protein), fat, ash and carbohydrates. The problem under consideration can be solved by applying reference materials of food composition, traceable to state primary measurement standards GET 173-2017 and GET 176-2019 and primary reference measurement procedures (PRMP), for attestation of measurement procedures and accuracy checking of measurement results. The article discusses the results of the PRMP development of mass fraction of fat, ash and carbohydrates in food products and food raw materials, as well as mass fraction of crude fat (oil content) in oil crops seeds and products based on them. The paper also presents metrological characteristics of reference materials of composition of dry dairy products, grain-milk dry porridges for nutrition of babies, grain dry porridges for nutrition of babies, egg powder, freeze-dried meat products, animal feed. The results of the work allow for building a chain of metrological traceability from GET 173-2017, GET 176-2019 and PRMP to routine measurement procedures, thereby ensuring the uniformity of measurements of nutritional value of food products.


Author(s):  
E. N. Simakova ◽  
O. V. Stenkova

Introduction. Glaucoma is one of the most significant eye diseases. It is often diagnosed, not always amenable to therapy, and can lead to a complete loss of visual functions. In recent years, the method of osteopathic correction has become widespread as one of the effective methods of treatment and rehabilitation of patients with pathologies of various body systems. In the pathogenesis of glaucoma, it is customary to distinguish a dystrophic concept, which considers primary open-angle glaucoma as a result of dystrophic changes in the connective tissue, as well as in the endothelial lining of the trabeculae and Schlemm′s canal, especially destructive changes in mitochondria and the alteration of their functional activity. A vascular concept is also distinguished. According to this concept, the central link in the pathogenesis of glaucoma is circulatory disorder in the ciliary vessels, ocular artery, and major vessels of the head and neck, it can be assumed that osteopathic correction in the treatment of patients with open-angle glaucoma will be pathogenetically substantiated and will have a positive effect on intraocular pressure and trophicity of the optic nerve. The goal of research — to study the influence of in osteopathic correction on the nature of unoperated glaucoma (stage IIA) and to substantiate the possibility of using osteopathic correction in the complex treatment of patients with this pathology.Materials and methods. A prospective controlled randomized study was conducted at 52 city polyclinics, branch 3, Moscow, from January 2018 to January 2019. 40 patients (70 eyes) aged 50 to 75 years with primary open-angle glaucoma IIA stage were examined. At this stage of the disease, patients most often seek medical care and the issue of conservative management is primarily considered. All patients were divided into two groups of 20 people: the main group and the control group. The treatment in the main group included hypotensive drug therapy and osteopathic correction. Patients of the control group received only drug therapy. All patients underwent ophthalmic (visometry, tonometry, perimetry) and osteopathic examination twice: before the treatment and after 3 months.Results. For patients with primary open-angle IIA non-operated glaucoma, regional (most often regions of the head, neck, dura mater) and local (abdominal diaphragm, iliac bones, hip and knee joints) somatic dysfunctions were the most typical. In the main group a statistically significant decrease in the frequency and severity of dysfunctions at all levels was stated. Also, in patients receiving osteopathic correction, a significant decrease in the level of intraocular pressure and perimetric indices was noted. In patients of the control group, no reliable changes in these indicators were obtained.Conclusion. The results obtained indicate that osteopathic correction is clinically effective in the complex treatment of patients with primary open-angle II A glaucoma.