The 14-year Performance of a Compacted Clay Liner used as Part of a Composite Liner System for a Leachate Lagoon

2005 ◽  
Vol 23 (6) ◽  
pp. 657-678 ◽  
Author(s):  
Craig B. Lake ◽  
R. Kerry Rowe
2014 ◽  
Vol 989-994 ◽  
pp. 1208-1211 ◽  
Author(s):  
Jing Jing Fan

An analytical model is established to predict the seepage performance of the liner system composed of a compacted clay liner (CCL) covered by a geomembrane (GM). The contaminant of Pb2+diffusing through the geomembrane is assumed to be a steady-state process. The liner systems with low leakage performance are usually utilized in the municipal solid waste landfills to prevent the contaminants of the leachate from polluting the groundwater and soil beneath the landfill. To investigate the seepage rate of the Pb2+in the liner systems of the landfill considering the effects of the geomembrance, the influence of the geomembrance on the seepage performance of the liner system is studied. Parametric analyses are conducted to study the effects of the thickness of GM and the number of defects in the GM on the leakage performance of the liner system. In conclusion, some suggestions for the design of the municipal solid waste landfills are proposed based on the analyses results.


2021 ◽  
Vol 13 (13) ◽  
pp. 7301
Author(s):  
Marcin K. Widomski ◽  
Anna Musz-Pomorska ◽  
Wojciech Franus

This paper presents research considering hydraulic as well as swelling and shrinkage characteristics of potential recycled fine particle materials for compacted clay liner for sustainable landfills. Five locally available clay soils mixed with 10% (by mass) of NaP1 recycled zeolite were tested. The performed analysis was based on determined plasticity, cation exchange capacity, coefficient of saturated hydraulic conductivity after compaction, several shrinkage and swelling characteristics as well as, finally, saturated hydraulic conductivity after three cycles of drying and rewetting of tested specimens and the reference samples. The obtained results showed that addition of zeolite to clay soils allowed reduction in their saturated hydraulic conductivity to meet the required threshold (≤1 × 10−9 m/s) of sealing capabilities for compacted clay liner. On the other hand, an increase in plasticity, swelling, and in several cases in shrinkage, of the clay–zeolite mixture was observed. Finally, none of the tested mixtures was able to sustain its sealing capabilities after three cycles of drying and rewetting. Thus, the studied clayey soils mixed with sustainable recycled zeolite were assessed as promising materials for compacted liner construction. However, the liner should be operated carefully to avoid extensive dissication and cracking.


1989 ◽  
Vol 16 (4) ◽  
pp. 552-559 ◽  
Author(s):  
Peter A. L. Richards ◽  
Christopher D. Thompson

The Provisional Certificate of Approval to construct a sanitary landfill for municipal waste in an old gravel pit in the Oak Ridges Moraine north of Toronto, Ontario, required that a 1.2 m thick compacted clay liner with a permeability of less than 10−8 cm/s should be placed beneath any refuse. Preliminary testing indicated that the native tills from the immediate vicinity were marginally capable of providing such a liner, as long as they were carefully selected and compacted at moisture contents just above optimum values. However, it was clear that the variability of material and (or) testing was such that some liner samples could have permeabilities greater than 10−8 cm/s. Additionally, there was concern that the sampling and testing procedures could affect the results. This paper details the trials which were carried out at the beginning of construction to establish acceptable sampling and testing techniques.These were finally determined to consist of carefully obtained Shelby tube samples, the permeability of which was tested at representative pressures in triaxial cells. The paper then presents the statistical analyses which were used to verify that the overall permeability of the liner is less than 10−8 cm/s. It also outlines other testing and instrumentation which has been undertaken to verify the liner permeability and integrity. It is concluded that, to date, the permeability testing and protocol are suitable control procedures to verify compliance with the condition of the Provisional Certificate of Approval that a liner permeability of 10−8 cm/s be achieved. Key words: clay liner, permeability, protocol, quality control, sanitary landfill, sampling, statistical analysis, testing.


2003 ◽  
Vol 40 (3) ◽  
pp. 536-550 ◽  
Author(s):  
R Kerry Rowe ◽  
Henri P Sangam ◽  
Craig B Lake

A geomembrane – compacted clay composite liner system used to contain municipal solid waste (MSW) landfill leachate for 14 years is evaluated. Field observations of the geomembrane revealed many defects, including holes, patches, and cracks. Physical, chemical, and mechanical tests conducted on samples collected from five different locations of the liner suggest that samples continuously exposed to sunlight and high temperatures experienced more degradation compared to samples that were covered by leachate or soil. Sorption and diffusion tests revealed that the permeation coefficients of volatile organic compounds were in the range of 4 × 10–12 to 6 × 10–11 m2/s and that, with respect to these parameters, there was no significant difference between samples with different exposure levels. However, the permeation coefficients were between four and five times lower than values obtained for unaged HDPE geomembranes typical of present day production. Contaminant modelling of the entire lagoon liner suggests that the geomembrane liner most likely stopped being effective as a contaminant barrier to ionic species sometime between 0 and 4 years after the installation.Key words: liquid containment, composite liner, diffusion, HDPE geomembrane, performance.


2014 ◽  
Vol 989-994 ◽  
pp. 433-436 ◽  
Author(s):  
Jing Jing Fan

To protect the underlying soil and groundwater from landfills, the landfills are commonly lined with layered liner systems. Geosynthetic clay liners (GCL) have been increasingly used in the landfill liner systems to substitude the traditional compacted clay liners (CCL) because of their low cost, easily construction behavior and low leakage rate. To study the behavior of the GM+GCL liner system used in China due to the migration of Pb2+, we introduce in detail GM+GCL liner systems proposed by the Chinese specification. Then one dimensional finite layer model is used to investigate the anti-pollution behavior of the CM+GCL composite liner systems, with the focuses on the heavy metal Pb2+. It could be concluded that the main migration way through the GM+GCL composite liner system is that the transport of Pb2+through a GM+GCL composite liner system of a landfill cover takes place primarily through the holes in the GM. The findings provide useful reference for preventing, controlling and treating groundwater pollution in the GM+GCL liner system technically and scientifically.


Author(s):  
Sanjay Kumar Shukla ◽  
Pavan Chauhan ◽  
M. Muthukumar ◽  
Apurv Kumar ◽  
Dharmil Baldev

Sign in / Sign up

Export Citation Format

Share Document