scholarly journals Reliable Angle Assessment During Periacetabular Osteotomy with a Novel Device

2008 ◽  
Vol 466 (5) ◽  
pp. 1169-1176 ◽  
Author(s):  
Anders Troelsen ◽  
Brian Elmengaard ◽  
Lone Rømer ◽  
Kjeld Søballe
2019 ◽  
Vol 9 (9) ◽  
pp. 608-613
Author(s):  
Dr. Swapna Lingaldinna,Dr. Himabindu Singh,Mona Sharma*

Objective: To measure the accuracy of a novel device in detecting Bradycardia andDesaturation (B&D) events and to determine its efficacy in resolving apneas innewborns with comparison to standard monitor (which only detects B&D eventsand alerts).Design: This was a prospective observational study.Setting: Sick Newborn Care Unit of a large tertiary referral hospital in Hyderabad,India.Methods: 31 newborns were provided with a novel device, which monitored oxygensaturation and pulse rate and alarmed when values dropped below a set thresholdwhich is referred as an event, henceforth. The novel device also provided footstimulation in response to above-mentioned events. When the monitor alarmed, anurse attended to the baby to confirm whether the baby was breathing and whetherthe event had been resolved by the device. If the event had not resolved, appropriateaction as per the standard-of-care was performed.Results: The novel device “ApneBootTM” positively detected B&D events 94.03% oftimes as compared to the standard reference monitor. 56 of 67 observed B&D eventswere visually confirmed to be apneas, indicating that 83.6% of B&D eventscoincided with apneas. Of the 56 apneic events, 50 were central apneas, of which 35were resolved by the novel device, making the device’s efficacy of apnea resolution70%.Conclusion: The results of the study indicate that this novel device “ApneBootTM”is very effective in detecting and alarming B&D events, which coincides with theapnea, and resolving it by providing foot stimulation.Keywords: Novel Device, Neonatal Apnea, Low Birth Weight, Body Temperature,Kangaroo Mother Care, Community Health,


Author(s):  
Flavia Bastos ◽  
ALEXANDRE SCARI ◽  
BRUNO GONCALVES SCHRODER e SOUZA ◽  
Fabiane Grazielle Silva

2020 ◽  
Author(s):  
Andrés Herane-Vives

BACKGROUND “Short-term” samples are not the most appropriate for reflecting Chronic Cortisol Concentration (CCC). Although hair is used for reflecting the systemic cortisol level over “long-term”, its use appears clinically problematic. Local stress and non-stress related factors may release a circumscribed cortisol secretion that is accumulated in hair. Non-stressful earwax extraction methods may provide a more accurate specimen to measure CCC. OBJECTIVE Correlate cortisol levels using hair, serum and earwax samples METHODS Earwax from both ears of 37 controls were extracted using a clinical procedure commonly associated with local pain. One month later, earwax from the left ear side was extracted using the same procedure, and earwax from the right ear side was comfortably extracted, using an earwax self-sampling device. Participants also provided one centimetre of hair that represented the retrospective month of cortisol output, and one serum sample that reflected the effect of systemic stressors on cortisol levels. Earwax (ECC), Hair (HCC) and Serum (SCC) Cortisol Concentration were correlated and compared. Confounders´ effect on cortisol levels were studied. RESULTS Serum showed the largest and hair the lowest cortisol concentration (p<0.01). Left-ECC was larger than Right-ECC (p=0.03). Right-ECC was the only sample unaffected by confounders (all p>0.05). Right-ECC and HCC showed the only significant association (r=0.39; p=0.03). CONCLUSIONS The self-sampling device did not represent a local stressor for the ceruminous glands. It provided the cortisol level with the least likely to be affected by confounding factors over the previous month. ECC using the novel device may constitute another accurate, but more suitable and affordable specimen for measuring CCC.


2005 ◽  
Vol 41 (5) ◽  
pp. 233-236 ◽  
Author(s):  
Nathan R. Selden ◽  
Susan R. Durham ◽  
Gregory J. Anderson ◽  
Dana A.V. Braner

Author(s):  
Vincent Justus Leopold ◽  
Juana Conrad ◽  
Robert Karl Zahn ◽  
Christian Hipfl ◽  
Carsten Perka ◽  
...  

Abstract Aims The aim of this study was to compare the fixation stability and complications in patients undergoing periacetabular osteotomy (PAO) with either K-wire or screw fixation. Patients and methods We performed a retrospective study to analyze a consecutive series of patients who underwent PAO with either screw or K-wire fixation. Patients who were treated for acetabular retroversion or had previous surgery on the ipsilateral hip joint were excluded. 172 patients (191 hips: 99 K-wire/92 screw fixation) were included. The mean age at the time of PAO was 29.3 years (16–48) in the K-wire group and 27.3 (15–45) in the screw group and 83.9% were female. Clinical parameters including duration of surgery, minor complications (soft tissue irritation and implant migration) and major complications (implant failure and non-union) were evaluated. Radiological parameters including LCE, TA and FHEI were measured preoperatively, postoperatively and at 3-months follow-up. Results Duration of surgery was significantly reduced in the K-wire group with 88.2 min (53–202) compared to the screw group with 119.7 min (50–261) (p < 0.001). Soft tissue irritation occurred significantly more often in the K-wire group (72/99) than in the screw group (36/92) (p < 0.001). No group showed significantly more implant migration than the other. No major complications were observed in either group. Postoperative LCE, TA and FHEI were improved significantly in both groups for all parameters (p = < 0.0001). There was no significant difference for initial or final correction for the respective parameters between the two groups. Furthermore, no significant difference in loss of correction was observed between the two groups for the respective parameters. Conclusion K-wire fixation is a viable and safe option for fragment fixation in PAO with similar stability and complication rates as screw fixation. An advantage of the method is the significantly reduced operative time. A disadvantage is the significantly higher rate of implant-associated soft tissue irritation, necessitating implant removal. Level of evidence III, retrospective trial.


Open Ceramics ◽  
2021 ◽  
pp. 100089
Author(s):  
Oscar Santoliquido ◽  
Francesco Camerota ◽  
Alice Rosa ◽  
Alberto Ortona

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yuta Seki ◽  
Daisuke Nakashima ◽  
Yasuyuki Shiraishi ◽  
Toshinobu Ryuzaki ◽  
Hidehiko Ikura ◽  
...  

AbstractThe lactate threshold (LT1), which is defined as the first rise in lactate concentration during incremental exercise, has not been non-invasively and conveniently determined in a clinical setting. We aimed to visualize changes in lactate concentration in sweat during exercise using our wearable lactate sensor and investigate the relationship between the lactate threshold (LT1) and ventilatory threshold (VT1). Twenty-three healthy subjects and 42 patients with cardiovascular diseases (CVDs) were enrolled. During exercise, the dynamic changes in lactate values in sweat were visualized in real-time with a sharp continuous increase up to volitional exhaustion and a gradual decrease during the recovery period. The LT1 in sweat was well correlated with the LT1 in blood and the VT1 (r = 0.92 and 0.71, respectively). In addition, the Bland–Altman plot described no bias between the mean values (mean differences: − 4.5 and 2.5 W, respectively). Continuous monitoring of lactate concentrations during exercise can provide additional information for detecting the VT1.


2021 ◽  
Vol 92 (4) ◽  
pp. 045106
Author(s):  
R. I. Kosheleva ◽  
T. D. Karapantsios ◽  
M. Kostoglou ◽  
A. Ch. Mitropoulos

2021 ◽  
Vol 10 (3) ◽  
pp. 394
Author(s):  
Jannis Löchel ◽  
Viktor Janz ◽  
Vincent Justus Leopold ◽  
Michael Krämer ◽  
Georgi I. Wassilew

Background: Patients undergoing periacetabular osteotomy (PAO) may experience significant postoperative pain due to the extensive approach and multiple osteotomies. The aim of this study was to assess the efficacy of the transversus abdominis plane (TAP) block on reducing opioid consumption and improving clinical outcome in PAO patients. Patients and Methods: We conducted a two-group randomized-controlled trial in 42 consecutive patients undergoing a PAO for symptomatic developmental dysplasia of the hip (DDH). The study group received an ultrasound-guided TAP block with 20 mL of 0.75% ropivacaine prior to surgery. The control group did not receive a TAP block. All patients received a multimodal analgesia with nonsteroidal anti-inflammatory drugs (NSAID) (etoricoxib and metamizole) and an intravenous patient-controlled analgesia (PCA) with piritramide (1.5 mg bolus, 10 min lockout-time). The primary endpoint was opioid consumption within 48 h after surgery. Secondary endpoints were pain scores, assessment of postoperative nausea and vomiting (PONV), measurement of the quality of recovery using patient-reported outcome measure and length of hospital stay. Forty-one patients (n = 21 TAP block group, n = 20 control group) completed the study, per protocol. One patient was lost to follow-up. Thirty-three were women (88.5%) and eight men (19.5%). The mean age at the time of surgery was 28 years (18–43, SD ± 7.4). All TAP blocks were performed by an experienced senior anaesthesiologist and all operations were performed by a single, high volume surgeon. Results: The opioid consumption in the TAP block group was significantly lower compared to the control group at 6 (3 mg ± 2.8 vs. 10.8 mg ± 5.6, p < 0.0001), 24 (18.4 ± 16.2 vs. 30.8 ± 16.4, p = 0.01) and 48 h (29.1 mg ± 30.7 vs. 54.7 ± 29.6, p = 0.04) after surgery. Pain scores were significantly reduced in the TAP block group at 24 h after surgery. There were no other differences in secondary outcome parameters. No perioperative complication occurred in either group. Conclusion: Ultrasound-guided TAP block significantly reduces the perioperative opioid consumption in patients undergoing PAO.


Sign in / Sign up

Export Citation Format

Share Document