Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation

2019 ◽  
Vol 12 (5) ◽  
pp. 905-919 ◽  
Author(s):  
Jiying Liu ◽  
Daniel Alejandro Dalgo ◽  
Shengwei Zhu ◽  
Hui Li ◽  
Linhua Zhang ◽  
...  
2019 ◽  
Vol 29 (4) ◽  
pp. 527-542 ◽  
Author(s):  
Jiying Liu ◽  
Zhuangzhuang Li ◽  
Moon Keun Kim ◽  
Shengwei Zhu ◽  
Linhua Zhang ◽  
...  

This study conducted a series of computational fluid dynamics simulations to evaluate the thermal comfort performance of a radiant floor cooling system when combined with different ventilation systems, including mixed ventilation (MV), stratum ventilation (SV), displacement ventilation (DV) and ductless personalized ventilation (DPV). A window temperature of 32°C and three different floor temperatures including 20, 22 and 24°C were set in summer. We used the vertical air temperature differences (VATD) at ankle and head level, the percentage of dissatisfied, the draught rate at the ankle level and the equivalent temperature as our main evaluation indices. Our results show that the VATD in DV system can reach up to about 5°C, compared with about 2°C in MV and SV systems. For the DPV system, there is only a marginal drop in the VATD. For the DV and DPV cases, with a rate of air changes per hour (ACH) of 2.4−1, we recorded a higher draught rate at the ankle level, ranging from 6.55% to 9.99%. The lower equivalent temperature values for the foot and calf segments occur when the floor temperature is 20°C. In all cases, the equivalent temperature values of the whole body indicate an acceptable level of thermal discomfort.


2013 ◽  
Vol 743 ◽  
pp. 90-93
Author(s):  
Wei Cai ◽  
Wen Lv ◽  
Le Xian Zhu ◽  
Peng Feng Yang

The purpose of this study is to investigate the thermal environment of a radiant floor cooling system using the existing radiant floor heating system. The thermal environment of the model office space was analyzed using Computational Fluid Dynamics (CFD) method. Two typical air distributions (hybrid air cooling system composed of radiant floor cooling and displacement ventilation and all-air system) were simulated. Installing two human models in the office, the characteristics of heat transportation from the human model were also analyzed. The results show that two air distribution forms can meet the demand of thermal comfort. The operative temperature in the radiant floor cooling system was lower than in the all-air cooling system when each of the sensible cooling loads of the two types of HVAC system was the same.


Author(s):  
Xiaosong Gu ◽  
Mingliang Cheng ◽  
Xiaofeng Zhang ◽  
Zixin Qi ◽  
Jiang Liu ◽  
...  

Author(s):  
Arup Chandra Saha ◽  
Vikas Verma ◽  
Rahul Tarodiya ◽  
M.R. Mahboob ◽  
Rajesh Kumar

2019 ◽  
Vol 180 ◽  
pp. 106-118 ◽  
Author(s):  
Ji-Xiang Wang ◽  
Yun-Ze Li ◽  
Jia-Xin Li ◽  
Chao Li ◽  
Yi Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document