radiant floor heating system
Recently Published Documents


TOTAL DOCUMENTS

72
(FIVE YEARS 29)

H-INDEX

12
(FIVE YEARS 3)

2021 ◽  
Vol 11 (11) ◽  
pp. 4806
Author(s):  
Michał Piasecki ◽  
Krystyna Barbara Kostyrko ◽  
Anna Goljan

The work aimed to investigate which parameters of the electrically powered radiant floor heating system are connected with the intensity of VOC total emissions and emissions from individual layers, which can be effectively changed and controlled to obtain energy savings in the ventilation process. For this purpose, experimental studies of VOC emissions from specially designed LRFHS samples (Laboratory Radiant Floor Heating System) were carried out, along with simulations of real thermal conditions of samples of layered systems containing separate heaters and various materials layers. The TD-GC-MS chromatography was used to assess the trends of VOCs concentration changes in 480 h in a test chamber (simulating real conditions) for several LRFHS systems of multilayer construction products with built-in individual heating systems, in two stabilised temperatures, 23 °C and 33 °C, two stabilised relative humidities, 50% and 80% and three air exchanges per hour ACH on levels 0.5, 1.0 and 1.5. The obtained results indicate that the models used to determine emissions from single-layer products correspond to the description of emissions from multilayer systems only to a limited extent; some inner layers of floor systems are giving diffusion resistance or intensification of diffusion. A new emission model is proposed. The time-emission concentration curves for dry and wet environments differ significantly; reducing the VOC concentration in the air for the number of exchanges above 1.0 ACH is relatively inefficient. Authors also mapped out new research directions; for example, the experiment showed that not all of the VOC contaminants are ventilated just as easily and perhaps, considering their concentration of resistant impurities, chemical structure and diffusion resistance through the layers, there is a need to determine their weights.


2021 ◽  
Author(s):  
Lindsay Fialkov

This major research project focuses on reducing the energy consumption, by modelling a radiant floor heating system with phase change materials, in the Toronto climate. Computer generated simulations were performed using DesignBuilder software, using an example of a typical condominium in Toronto .Two south facing suites and two north facing suites were investigated. Of those suites, one north facing suite had PCM below the finished floor, as well as one south facing suite. The objective of these simulations was to determine the impact of using PCM in the condo suites. Three different types of PCM were used, in order to determine which type had the biggest energy savings. The PCMs were M91/Q21, M51/Q21 and M27/Q21. The final results showed that the suites with the M27/Q21 PCM had the lowest energy usage. A cost savings comparison was performed based on the rate of energy used and the cost of the energy, provided by the Ontario Energy Board.


2021 ◽  
Author(s):  
Lindsay Fialkov

This major research project focuses on reducing the energy consumption, by modelling a radiant floor heating system with phase change materials, in the Toronto climate. Computer generated simulations were performed using DesignBuilder software, using an example of a typical condominium in Toronto .Two south facing suites and two north facing suites were investigated. Of those suites, one north facing suite had PCM below the finished floor, as well as one south facing suite. The objective of these simulations was to determine the impact of using PCM in the condo suites. Three different types of PCM were used, in order to determine which type had the biggest energy savings. The PCMs were M91/Q21, M51/Q21 and M27/Q21. The final results showed that the suites with the M27/Q21 PCM had the lowest energy usage. A cost savings comparison was performed based on the rate of energy used and the cost of the energy, provided by the Ontario Energy Board.


2021 ◽  
Vol 261 ◽  
pp. 01058
Author(s):  
Jiacheng Zheng ◽  
Tao Yu ◽  
Bo Lei ◽  
Ruixin Lv ◽  
Chen Chen ◽  
...  

In cold regions, radiant floor heating systems are commonly used in public buildings due to better thermal comfort and lower energy consumption. However, in transportation buildings with many transparent envelopes such as railway stations on Tibetan Plateau, the strong solar radiation entering into the station may cause local overheating, which has a great effect on the radiant floor heating system. In this paper, a railway station on Tibetan Plateau is simulated to investigate the influence of uneven solar radiation distribution on the radiant floor heating system. Results show that due to the strong solar radiation, the floor surface temperature and indoor operative temperature in some parts of the waiting hall can reach up to 30 °C and 26 °C, respectively. The temperature difference of the floor surface can even exceed 5 °C occasionally during the heating period. According to the results, it can be found that the method of reducing the heating in the area with strong solar radiation and making full use of solar radiation for heating is an effective way to improve the indoor thermal comfort and reduce the heating energy consumption of heating system.


Proceedings ◽  
2020 ◽  
Vol 63 (1) ◽  
pp. 15
Author(s):  
Marius Brănoaea ◽  
Andrei Burlacu ◽  
Vasilică Ciocan ◽  
Marina Verdeș ◽  
Robert Ștefan Vizitiu

The subject of buildings energy efficiency has gained increased interest in modern society. Recently, researchers aiming to reduce the energy demand of buildings have studied the implementation of phase change materials (PCMs) in various building elements. At the same time, researchers studied the implementation of unconventional technologies such as heat pipes (HP) in the buildings’ heating system. This paper combines both of these technologies in order to take advantage of the thermal storage properties of PCMs and overcome their reduced conductivity with heat pipes. Through computational fluid dynamics (CFD) simulations, this paper studies and highlights that with the implementation of a PCM, a reduction of the daily energy demand is achieved through the increase in the discharge phase time.


Sign in / Sign up

Export Citation Format

Share Document