scholarly journals A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material

2013 ◽  
Vol 13 (4) ◽  
pp. 428-438 ◽  
Author(s):  
Smita Sara Manoj ◽  
K. P. Cherian ◽  
Vidya Chitre ◽  
Meena Aras
2015 ◽  
Vol 12 (2) ◽  
pp. 111-117
Author(s):  
P K Parajuli ◽  
S George ◽  
V Shenoy

Background: Dual-arch impression technique allows the simultaneous recording of  tooth preparation, opposing anatomic tooth and maxillomandibular relationship. The  accuracy of reproduction of this easy and quick technique, however, has not been  studied in detail in past. Objective: To compare the accuracy of the impressions  made by using the same impression material in dual arch plastic trays, dual-arch  metal trays and acrylic resin custom trays. Methods: The dies obtained from the  addition silicone impressions made in dual-arch plastic trays, dual-arch metal trays  and full arch acrylic resin custom trays were compared for the dimensional accuracy  with the prepared typodont tooth as a control. Student’s paired t-test and unpaired  t-test were used for the data analyses using the Statistical Package for Social Studies  (SPSS) version 11.5. Results: The dies obtained from all the impression combinations  showed increased dimension (acrylic resin custom trays 9.4 mm±0.048, dual-arch  plastic trays 9.5 mm±0.035, dual-arch metal trays 9.41 mm±0.017) as compared to  the dimension of control (9.39 mm±0.007). Conclusion: All the tray-impression  material combinations showed variable accuracies. Full arch acrylic resin trays  resulted in greatest accuracy whereas dual-arch plastic trays the least accuracy.Health Renaissance 2014;12(2):  pp: 111-117


2013 ◽  
Vol 14 (2) ◽  
pp. 265-268 ◽  
Author(s):  
Naveen S Yadav ◽  
Teerthesh Jain ◽  
Amrita Pandita ◽  
SMA Feroz ◽  
Pradeep LNU ◽  
...  

ABSTRACT Aim Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. Materials and methods In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. Results Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. Conclusion All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. Clinical significance In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions. How to cite this article Pandita A, Jain T, Yadav NS, Feroz SMA, Pradeep, Diwedi A. Evaluation and Comparison of Dimensional Accuracy of Newly Introduced Elastomeric Impression Material using 3D Laser Scanners: An in vitro Study. J Contemp Dent Pract 2013;14(2):265-268.


2012 ◽  
Vol 13 (6) ◽  
pp. 842-849
Author(s):  
T Shankar ◽  
N Venugopal Rao ◽  
Snigdha Gowd ◽  
Syed Tauqheer Ahmed ◽  
V Vinod ◽  
...  

ABSTRACT Aim The aim of this study is to evaluate the dimensional accuracy of heat polymerized acrylic resin denture base clamped by the conventional method and by new-press technique and cured by long curing cycle. Materials and methods In this study, a total of 60 standardized maxillary record bases were fabricated with seven reference points as follows: • Point A Incisive papilla, • Point B and C Canine region on either side • Point E and G Midpoint of tuberosities on either side • Point F Midpoint of the line joining the two tuberosities • Point D Midpoint between the line joining A and F Group A Ten maxillary record bases were fabricated by conventional clamping method and cured by long curing cycle. Group A’ Ten maxillary record bases were fabricated by New Press or RS tension clamping method and cured by long curing cycle. The distances between the reference points, i.e. A-B, A-C, A-D, D-F, B-E, C-G, E-F, F-G, B-D, D-G, C-D, D-E of all three thermoplastic denture base plates were measured and recorded with the help of travelling microscope and were used for comparison with the measured and recorded readings of processed acrylic denture bases. The data obtained was analyzed by using the one-way analysis of variance and HSD Multiple Comparison Test. Results The overall results of the study indicate that among all the denture bases cured by the two clamping systems and the long curing cycle, group A‘ were the most dimensionally stable, followed by control group A. Conclusion The study concluded that the denture bases fabricated by the New Press method using the long curing cycle would produce the most dimensionally stable denture bases. How to cite this article Shankar T, Gowd S, Ahmed ST, Vinod V, Goud MV, Rao NV. A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study. J Contemp Dent Pract 2012;13(6):842-849.


1988 ◽  
Vol 32 (2) ◽  
pp. 315-319
Author(s):  
Goro Nishigawa ◽  
Kiwamu Ando ◽  
Masaki Inoue ◽  
Toru Ueyama ◽  
Masanori Yanagihara ◽  
...  

2019 ◽  
Vol 4 (2) ◽  
pp. 90-93
Author(s):  
Hussameldien Hussien ◽  
◽  
Natashekara Mallesh ◽  

Background of the study: Dental implants are one of the most sought-after choice of treatment for restoration and rehabilitation of missing teeth. However, the accuracy of the removable or fixed superstructures over the dental implants is influenced for a major proportion by the impression techniques and materials. This paper discusses the comparison of the accuracy of different impression materials and techniques used in the second stage of the dental implant treatment in vivo. Objective: The objective of the paper is to study the comparison of the accuracy of different impression materials and techniques used in the second stage of the dental implant’s treatment in vivo. Search methodology: Electronically key searched in scientific literature databases. Selection criteria: Based on the set inclusion and exclusion criteria such as studies conducted in partial edentulous arches, in the age group of 30 to 55 years. Data collection and analysis: A total of 248 literatures were found to be relevant to the framed topic and were scrutinised based on the dejected criteria and 18 kinds of literature obtained were taken into consideration. Main Result: Among the different impression materials taken into the comparative study, it was observed that polyvinyl siloxane exhibited a dimensional accuracy slightly greater than polyether. However, light body putty exhibited greater accuracy than medium body putty. Various impression techniques were compared to evaluate the dimensional accuracy of the impression. It was observed that the open tray technique and splinted impression technique produced a more dimensionally stable impression than the other techniques. Authors Conclusion: this study to assess the accuracy of various impression material and methods has concluded that while impression techniques influence the accuracy of the impression, the impression materials namely the Polyvinyl siloxane and polyether exhibit no significant difference with a slight preference to the polyvinyl siloxane. Hence the choice of impression material is at the discretion of the dentist performing the treatment and also this area requires further studies to establish conclusive evidence.


2014 ◽  
Vol 3 (2) ◽  
pp. 28-33
Author(s):  
Shakila Fatema ◽  
Sheikh Md Shahriar Quader ◽  
Mohammad Shamsuzzaman ◽  
Mirza Md Arifur Rahman ◽  
Nasima Khan

Background: To achieve accuracy and exact reproduction of prosthesis, choosing a perfect impression material is essential. Especially to make the prosthesis as accurately as possible, impression material should possess some essential properties, like; minimum dimensional changes, good flow ability and easy removal. Purpose: The aim of this study was to evaluate the accuracy and surface detail reproduction of Alginate and Addition Reaction Silicone as an impression materials. Method: This is an experimental in vitro study. In this study Impression by Alginate and Addition Reaction Silicone were made using a round stainless steel test block with three horizontal lines and two vertical lines. The horizontal lines were used for evaluating the surface detail reproduction, and vertical lines were provided for the dimensional accuracy. For dimensional accuracy the length of the middle horizontal line in between vertical lines and the distance between the top and bottom horizontal line was measured using travelling microscope. And for surface detail reproduction three horizontal line of one segment were observed under stereomicroscope. Result: According to study results Addition Reaction Silicone is better than Alginate regarding quality of impression. Conclusion: In comparison to Alginate, Addition Reaction Silicone might have better performance about accuracy and surface detail reproduction. DOI: http://dx.doi.org/10.3329/updcj.v3i2.17996 Update Dent. Coll. j: 2013; 3 (2): 28-33


Sign in / Sign up

Export Citation Format

Share Document