scholarly journals An in-vitro study to evaluate the accuracy of dies obtained from dual arch impression trays using addition silicone impression material and tray combinations

2015 ◽  
Vol 12 (2) ◽  
pp. 111-117
Author(s):  
P K Parajuli ◽  
S George ◽  
V Shenoy

Background: Dual-arch impression technique allows the simultaneous recording of  tooth preparation, opposing anatomic tooth and maxillomandibular relationship. The  accuracy of reproduction of this easy and quick technique, however, has not been  studied in detail in past. Objective: To compare the accuracy of the impressions  made by using the same impression material in dual arch plastic trays, dual-arch  metal trays and acrylic resin custom trays. Methods: The dies obtained from the  addition silicone impressions made in dual-arch plastic trays, dual-arch metal trays  and full arch acrylic resin custom trays were compared for the dimensional accuracy  with the prepared typodont tooth as a control. Student’s paired t-test and unpaired  t-test were used for the data analyses using the Statistical Package for Social Studies  (SPSS) version 11.5. Results: The dies obtained from all the impression combinations  showed increased dimension (acrylic resin custom trays 9.4 mm±0.048, dual-arch  plastic trays 9.5 mm±0.035, dual-arch metal trays 9.41 mm±0.017) as compared to  the dimension of control (9.39 mm±0.007). Conclusion: All the tray-impression  material combinations showed variable accuracies. Full arch acrylic resin trays  resulted in greatest accuracy whereas dual-arch plastic trays the least accuracy.Health Renaissance 2014;12(2):  pp: 111-117

Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1234
Author(s):  
António Sérgio Silva ◽  
Aurora Carvalho ◽  
Pedro Barreiros ◽  
Juliana de Sá ◽  
Carlos Aroso ◽  
...  

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.


2013 ◽  
Vol 14 (2) ◽  
pp. 265-268 ◽  
Author(s):  
Naveen S Yadav ◽  
Teerthesh Jain ◽  
Amrita Pandita ◽  
SMA Feroz ◽  
Pradeep LNU ◽  
...  

ABSTRACT Aim Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. Materials and methods In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. Results Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. Conclusion All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. Clinical significance In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions. How to cite this article Pandita A, Jain T, Yadav NS, Feroz SMA, Pradeep, Diwedi A. Evaluation and Comparison of Dimensional Accuracy of Newly Introduced Elastomeric Impression Material using 3D Laser Scanners: An in vitro Study. J Contemp Dent Pract 2013;14(2):265-268.


2014 ◽  
Vol 3 (2) ◽  
pp. 28-33
Author(s):  
Shakila Fatema ◽  
Sheikh Md Shahriar Quader ◽  
Mohammad Shamsuzzaman ◽  
Mirza Md Arifur Rahman ◽  
Nasima Khan

Background: To achieve accuracy and exact reproduction of prosthesis, choosing a perfect impression material is essential. Especially to make the prosthesis as accurately as possible, impression material should possess some essential properties, like; minimum dimensional changes, good flow ability and easy removal. Purpose: The aim of this study was to evaluate the accuracy and surface detail reproduction of Alginate and Addition Reaction Silicone as an impression materials. Method: This is an experimental in vitro study. In this study Impression by Alginate and Addition Reaction Silicone were made using a round stainless steel test block with three horizontal lines and two vertical lines. The horizontal lines were used for evaluating the surface detail reproduction, and vertical lines were provided for the dimensional accuracy. For dimensional accuracy the length of the middle horizontal line in between vertical lines and the distance between the top and bottom horizontal line was measured using travelling microscope. And for surface detail reproduction three horizontal line of one segment were observed under stereomicroscope. Result: According to study results Addition Reaction Silicone is better than Alginate regarding quality of impression. Conclusion: In comparison to Alginate, Addition Reaction Silicone might have better performance about accuracy and surface detail reproduction. DOI: http://dx.doi.org/10.3329/updcj.v3i2.17996 Update Dent. Coll. j: 2013; 3 (2): 28-33


2014 ◽  
Vol 40 (2) ◽  
pp. 137-145 ◽  
Author(s):  
Malesh Pujari ◽  
Pooja Garg ◽  
D. R. Prithviraj

Movement of impression copings inside the impression material using a direct (open tray) impression technique during clinical and laboratory phases may cause inaccuracy in transferring the 3-dimensional spatial orientation of implants intraorally to the cast. Consequently, the prosthesis may require corrective procedures. This in vitro study evaluated the accuracy of 3 different impression techniques using polyether and vinyl polysiloxane (VPS) impression material to obtain a precise cast for multiple internal connection implants. A reference acrylic resin model with 4 internal connection implants was fabricated. Impressions of the reference model were made using 3 different techniques and 2 different impression materials. The study consisted of 24 specimens divided into 6 groups of 4 each. Impressions were poured with ADA type IV stone (Kalrock, Kalabhai Karson Pvt Ltd, Mumbai, India). All casts were evaluated for the positional accuracy (mm) of the implant replica heads using a profile projector. These measurements were compared to the measurements calculated on the reference resin model, which served as a control. Data were analyzed with 2-way analysis of variance (ANOVA) followed by Bonferroni multiple comparison procedures to evaluate group means. The results revealed significant difference for anterior implant distance between the 2 impression materials (P < .01) and also among the 3 different techniques (P < .05). The lowest mean variation was found with the polyether impression material and the splinted technique. For posterior implants, the results suggested no significant difference between the 2 impression materials (P ≥ .05). Although results were not statistically significant, the polyether impression material showed the lowest mean variation as compared to the VPS impression material. However, there was a significant difference among the 3 different techniques (P < .05). Among the 3 different techniques, the lowest mean variation between 2 posterior implants was found in the splinted technique. Casts obtained from impression techniques using square impression copings splinted together with autopolymerizing acrylic resin prior to the impression procedure were more accurate than casts obtained from impressions with nonmodified implant impression copings and with airborne particle–abraded, adhesive-coated copings. Casts obtained from polyether impression material were more accurate than casts obtained from vinyl polysiloxane impression material.


2012 ◽  
Vol 13 (1) ◽  
pp. 98-106 ◽  
Author(s):  
Kishan Singh ◽  
Sukant Sahoo ◽  
KD Prasad ◽  
Meenu Goel ◽  
Anupam Singh

ABSTRACT Production of exemplary crowns and fixed partial dentures depends upon the usage of impression material and its technique of usage that accurately reproduces prepared teeth and their relationship to the adjacent oral structure. Aim To evaluate the linear dimensional accuracy of the elastomeric impressions using various impression techniques using different combinations of viscosities of impression materials. Materials and methods Crown preparation was done in a dentulous acrylic resin denture base model with six natural teeth embedded into it was made to represent the dentulous maxillary arch. A total of 55 impressions were obtained and poured in die stone using various impression techniques with different combinations of viscosities of impression materials. Results Among the six techniques used, the heavy body light body two-step technique using custom tray showed the least distortion which was closely followed by the putty wash two-step technique with 2 mm spacer using stock tray. Conclusion The study revealed that the heavy body light body two-step technique with custom tray provided the best results. Clinical significance Dimensional accuracy of impressions is very much required for precisely fitting of prosthesis. This study may be helpfull to select the technique and materials as per clinical requirement of accuracy of impressions. How to cite this article Singh K, Sahoo S, Prasad KD, Goel M, Singh A. Effect of Different Impression Techniques on the Dimensional Accuracy of Impressions using Various Elastomeric Impression Materials: An in vitro Study. J Contemp Dent Pract 2012;13(1):98-106.


2017 ◽  
Vol 65 (1) ◽  
pp. 25-29
Author(s):  
Rafael Pino VITTI ◽  
Victor Pinheiro FEITOSA ◽  
Ataís BACCHI ◽  
William Cunha BRANDT ◽  
Milton Edson MIRANDA ◽  
...  

ABSTRACT Objective: The purpose of this in vitro study was to assess and compare the dimensional accuracy of three impression techniques: 1-step putty/light-body, 2-step putty/light-body, and the monophase technique. Methods: A partially edentulous standard stainless steel mandibular arch cast with reference points on the teeth was used to make the impressions. The anteroposterior and transverse distances were measured. All impressions were made with a polyvinyl siloxane using stock metallic (1- and 2-step putty/light-body techniques) or acrylic resin (monophase technique) trays. The monophase impressions were made using a light-body material and the 1- and 2-step putty/light-body impressions with putty and light-body materials. After impression procedures, the accuracy of each technique was assessed measuring the stone casts (n = 5) poured from the impressions using a microscope at 30x magnification and at 0.5 µm accuracy. The data were analyzed statistically using 2-way ANOVA and Tukey's test (p<0.05). Results: Stone casts made by all techniques had significantly negative linear changes (shrinkage). The anteroposterior distances showed more dimensional changes than the transverse distances. The edentulous side showed more shrinkage than the anteroposterior side. Conclusion: No differences between the impression techniques were found, but significant dimensional changes were observed.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Ali Hafezeqoran ◽  
Mahdi Rahbar ◽  
Roodabeh Koodaryan ◽  
Tina Molaei

Introduction. The dimensional accuracy of casts is essential in the quality of fixed prosthesis treatment, whereby the impression method is a very crucial factor affecting it. The aim of this in vitro study is to compare the dimensional accuracy of casts resulting from two types of silicone impression materials in different impression techniques and frequent times of cast preparation. Materials and Methods. A metal model was made from two prepared abutments, and 10 casts were prepared from each material technique (n = 40). The impressions were made by condensation and addition silicone (one-stage and two-stage impressions). The casts were made from same impressions 1 h, 24 h, and 14 days. The diameter, height, and the distance between two dies were recorded. Data were analyzed by repeated measure ANOVA (P value <0.05). Results. The dimensional accuracy of all four materials techniques of impression (diameter, height, and the distance between dies) was the same in different times of impression. Dimensional accuracy of the die diameter and distance between dies in one-stage (Speedex) condensation silicon and one-stage (Panasil) addition silicone did not differ significantly, and their one-stage method developed more accurate casts compared to the two-stage method of the same impression material. The height of the casts prepared from the one-stage method through Speedex and Panasil did not differ significantly from the two-stage method of the same impression material. Conclusion. One-stage condensation silicone and one-stage addition silicone material techniques offered the maximum dimensional accuracy in the obtained casts. The time of impression did not have any significant effect in the accuracy of any of the four impression material techniques.


2020 ◽  
Vol 21 (2) ◽  
pp. 190-196
Author(s):  
Preetam A Mahagaonkar ◽  
Prabhakar B Angadi ◽  
Nihar R Naik ◽  
Vinay Kakatkar ◽  
Yogesh S Sonawane

Sign in / Sign up

Export Citation Format

Share Document