scholarly journals Comparison of 2D 4K vs. 3D HD laparoscopic imaging systems using a pelvitrainer model: a randomized controlled study

Author(s):  
Tibor A. Zwimpfer ◽  
Claudine Wismer ◽  
Bernhard Fellmann-Fischer ◽  
James Geiger ◽  
Andreas Schötzau ◽  
...  

AbstractLaparoscopic surgery provides well-known benefits, but it has technological limitations. Depth perception is particularly crucial, with three-dimensional (3D) imaging being superior to two-dimensional (2D) HD imaging. However, with the introduction of 4K resolution monitors, 2D rendering is capable of providing higher-quality visuals. Therefore, this study aimed to compare 3D HD and 2D 4K imaging using a pelvitrainer model. Eight experts and 32 medical students were performing the same four standardized tasks using 2D 4K and 3D HD imaging systems. Task completion time and the number of errors made were recorded. The Wilcoxon test and mixed-effects models were used to analyze the results. Students were significantly faster in all four tasks when using the 3D HD perspective. The median difference ranged from 18 s in task 3 (P < 0.003) up to 177.5 s in task 4 (P < 0.001). With the exception of task 4, students demonstrated significantly fewer errors in all tasks involving 3D HD imaging. The experts’ results confirmed these findings, as they were also faster in all four tasks using 3D HD, which was significant for task 1 (P < 0.001) and task 4 (P < 0.006). The expert group also achieved better movement accuracy using the 3D HD system, with fewer mistakes made in all four tasks, which was significant in task 4 (P < 0.001). Participants in both groups achieved better results with the 3D HD imaging system than with the 2D 4K system. The 3D HD image system should be used when available. Trial registration: this trial is registered at research registry under the identifier researchregistry6852.

2021 ◽  
Author(s):  
Nitin Dubey ◽  
Joseph Rosen

Abstract Interferenceless coded aperture correlation holography (I-COACH) is an incoherent digital holographic technique with lateral and axial resolution similar to a regular lens-based imaging system. The properties of I-COACH are dictated by the shape of the system’s point response termed point spread hologram (PSH). As previously shown, chaotic PSHs which are continuous over some area on the image sensor enable the system to perform three-dimensional (3D) holographic imaging. We also showed that a PSH of an ensemble of sparse dots improves the system’s signal-to-noise ratio (SNR) but reduces the dimensionality of the imaging from three to two dimensions. In this study, we test the midway shape of PSH, an ensemble of sparse islands distributed over the sensor plane. A PSH of isolated chaotic islands improves the SNR of the system compared to continuous chaotic PSH without losing the capability to perform 3D imaging. Reconstructed images of this new system are compared with images of continuous PSH, dot-based PSH, and direct images of a lens-based system. Visibility, SNR, and the product of visibility with SNR are the parameters used in the study. We also demonstrate the imaging capability of a system with partial annular apertures. The reconstruction results have better SNR and visibility than lens-based imaging systems with the same annular apertures.


2012 ◽  
Vol 31 (2) ◽  
pp. 65 ◽  
Author(s):  
Eric Pirard

In recent years, impressive progress has been made in digital imaging and in particular in three dimensional visualisation and analysis of objects. This paper reviews the most recent literature on three dimensional imaging with a special attention to particulate systems analysis. After an introduction recalling some important concepts in spatial sampling and digital imaging, the paper reviews a series of techniques with a clear distinction between the surfometric and volumetric principles. The literature review is as broad as possible covering materials science as well as biology while keeping an eye on emerging technologies in optics and physics. The paper should be of interest to any scientist trying to picture particles in 3D with the best possible resolution for accurate size and shape estimation. Though techniques are adequate for nanoscopic and microscopic particles, no special size limit has been considered while compiling the review.


2021 ◽  
Vol 67 (4) ◽  
pp. 449-461
Author(s):  
Aliyeh Daryabor ◽  
Gholamreza Aminian ◽  
Mokhtar Arazpour ◽  
Mina Baniasad ◽  
Sumiko Yamamoto

Objectives: This study aims to evaluate the effect of two ankle-foot orthoses (AFOs), AFO with plantar flexion stop (AFO-PlfS), and AFO with plantar flexion resistance (AFO-PlfR), while wearing standard shoes and rocker-sole shoes. Patients and methods: Between November 2017 and July 2018, in this randomized-controlled study, a total of 20 stroke patients (8 males, 12 females; mean age: 48.1 years; range, 33 to 65 years) in chronic phase were randomized to AFO groups (AFO-PlfS group, n=10 and AFO-PlfR group, n=10). Each group received the allocated AFO along with two kinds of shoes (standard shoe and rocker shoe) for a two-week adaptation. Two effects were separately evaluated: The orthotic effect and rocker shoe effect were defined as the evaluation of using an AFO wearing standard shoe compared to only standard shoe, and evaluation of using an AFO wearing rocker shoe compared to an AFO wearing standard shoe, respectively. The gait of each group was measured by three-dimensional motion analysis. Results: A significant orthotic effect was found in both AFO groups in spatiotemporal parameters and maximum ankle dorsiflexion in the single-support phase. Additionally, the AFO-PlfR group showed a significant improvement in the parameters related to the first rocker of gait, but not for AFO-PlfS group concerning the orthotic effect. The rocker shoe effect was found in significant reduction of peak ankle plantar flexor moment and power ankle generation during preswing for both AFO groups. Conclusion: According to the orthotic effect, an AFO-PlfR can create better function in the improvement of parameters related to the first rocker. Although a rocker shoe can facilitate rollover for weight progression in the third rocker of gait, it cannot make a strong push-off function in stroke survivors.


Author(s):  
S. Kolokytha ◽  
R. Speller ◽  
S. Robson

This study describes a cost-effective check-in baggage screening system, based on "on-belt tomosynthesis" (ObT) and close-range photogrammetry, that is designed to address the limitations of the most common system used, conventional projection radiography. The latter's limitations can lead to loss of information and an increase in baggage handling time, as baggage is manually searched or screened with more advanced systems. This project proposes a system that overcomes such limitations creating a cost-effective automated pseudo-3D imaging system, by combining x-ray and optical imaging to form digital tomograms. Tomographic reconstruction requires a knowledge of the change in geometry between multiple x-ray views of a common object. This is uniquely achieved using a close range photogrammetric system based on a small network of web-cameras. This paper presents the recent developments of the ObT system and describes recent findings of the photogrammetric system implementation. Based on these positive results, future work on the advancement of the ObT system as a cost-effective pseudo-3D imaging of hold baggage for airport security is proposed.


2013 ◽  
Vol 475-476 ◽  
pp. 259-262
Author(s):  
Fei Wang

Range accuracy is one of the key parameters for 3D laser imaging systems. A gain-modulated 3D imaging system employing multi-pulse accumulation method is proposed to improve the range accuracy performance. Experiments results show that the range error decreases exponentially with the number of accumulated laser echoes.


Author(s):  
Bala Muralikrishnan ◽  
Prem Rachakonda ◽  
Vincent Lee ◽  
Meghan Shilling ◽  
Daniel Sawyer ◽  
...  

The relative-range error test is one of several tests described in the ASTM E3125-2017 standard for performance evaluation of spherical coordinate three-dimensional (3D) imaging systems such as terrestrial laser scanners (TLS). We designed a new artifact, called the plate-sphere target, that allows the realization of the relative-range error tests quickly and efficiently without the need for alignment at each position of the test. Use of a simple planar/plate target requires careful alignment of the target at each position of the relative-range error test, which is labor-intensive and time-consuming. This new artifact significantly reduces the time required to perform the test, from a matter of about 2 h to less than 30 min while resulting in similar test uncertainty values. The plate-sphere target was conceived and initially developed at the National Institute of Standards and Technology (NIST), improved based on feedback from collaborators at the National Research Council (NRC) of Canada and TLS manufacturers, and commercialized by Bal-tec Inc. This new artifact will save users and manufacturers of TLSs considerable time and money.