Determination of Effective Parameters for Alpha-Amylase Production in a Modified Rotating Drum Bioreactor

2018 ◽  
Vol 43 (7) ◽  
pp. 3381-3391 ◽  
Author(s):  
M. A. Uygut ◽  
M. Ş. Tanyildizi
2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Wajid Ali Khan ◽  
Muhammad Balal Arain ◽  
Hashmat Bibi ◽  
Mustafa Tuzen ◽  
Nasrullah Shah ◽  
...  

AbstractIn this study, an extremely effective electromembrane extraction (EME) method was developed for the selective extraction of Cu(II) followed by Red-Green-Blue (RGB) detection. The effective parameters optimized for the extraction efficiency of EME include applied voltage, extraction time, supported liquid membrane (SLM) composition, pH of acceptor/donor phases, and stirring rate. Under optimized conditions, Cu(II) was extracted from a 3 mL aqueous donor phase to 8 µL of 100 mM HCl acceptor solution through 1-octanol SLM using an applied voltage of 50 V for 15 min. The proposed method provides a working range of 0.1–0.75 µg·mL−1 with 0.03 µg·mL−1 limit for detection. Finally, the developed technique was applied to different environmental water samples for monitoring environmental pollution. Obtained relative recoveries were within the range of 93–106%. The relative standard deviation (RSD) and enhancement factor (EF) were found to be ≤4.8% and 100 respectively. We hope that this method can be introduced for quantitative determination of Cu(II) as a fast, simple, portable, inexpensive, effective, and precise procedure.


1978 ◽  
Vol 24 (9) ◽  
pp. 1620-1624 ◽  
Author(s):  
W H Porter ◽  
R E Roberts

Abstract We evaluated the Harleco alpha-glucosidase/hexokinase/glucose-6-phosphate dehydrogenase-coupled alpha-amylase method, bu use of the GEMSAEC centrifugal analyzer. Performance evaluation included kinetic studies of substrate and maltose hydrolysis as well as effects of endogenous glucose and fructose. The reagent was found to give a linear response with alpha-amylase activity to greater than 1200 U/liter. Within-run precision resulted in coefficients of variation (CV) of 0.9 to 3.2% over the range studied. Day-to-day precision corresponded to CV's of 2.4 to 4.4% over the same range of alpha-amylase procedure was found to be good (r = 0.997) for patients' sera examined.


1978 ◽  
Vol 24 (4) ◽  
pp. 702-705 ◽  
Author(s):  
C C Garber ◽  
R N Carey

Abstract Protein activation of urinary alpha-amylase (EC 3.2.1.1) activity was observed during an evaluation of the Du Pont aca procedure for the determination of urinary alpha-amylase. This activation effect became constant for urinary albumin concentrations exceeding 1.50 g/liter. It is recommended that urinary alpha-amylase be analyzed with sufficient albumin added to maximize this effect. The aca alpha-amylase procedure is compared to an amyloclastic method for both serum and urine analysis. Expected ranges are presented for the aca method for serum and urinary amylase, amylase clearance, and the amylase clearance/creatinine clearance ratio.


Sign in / Sign up

Export Citation Format

Share Document