Linear dynamic analysis of revolutional shells using finite elements and modal expansion

1983 ◽  
Vol 86 (4) ◽  
pp. 523-538 ◽  
Author(s):  
Y.B. Chang ◽  
T.Y. Yang ◽  
W. Soedel
2021 ◽  
Vol 11 (11) ◽  
pp. 4898
Author(s):  
Jin-Seon Kim ◽  
Ju-Seong Jung ◽  
Dong-Keun Jung ◽  
Eui-Yong Kim ◽  
Kang-Seok Lee

The present study proposes a new seismic retrofitting method using a concrete-filled tube modular frame (CFT-MF) system, a novel technique to overcome and improve the limitations of existing seismic strengthening methods. This CFT-MF seismic retrofitting method makes the most of the advantages of both concrete and steel pipes, thereby significantly improving constructability and increasing integration between the existing structure and the reinforcement joints. This method falls into the category of typical seismic retrofitting methods that focus on increasing strength, in which the required amount of seismic reinforcement can be easily estimated. Therefore, the method provides an easy solution to improving the strength of existing reinforced concrete (RC) structures with non-seismic details that are prone to shear failure. In the present study, a full-size two-story test frame modeled from existing domestic RC structures with non-seismic details was subjected to pseudo-dynamic testing. As a result, the effect of the CFT-MF system, when applied to existing RC structures, was examined and verified, especially as to its seismic retrofitting performance, i.e., restoring force characteristics, stiffness reinforcement, and seismic response control. In addition, based on the pseudo-dynamic testing results, a restoring force characteristics model was proposed to implement non-linear dynamic analysis of a structure retrofitted with the CFT-MF system (i.e., the test frame). Finally, based on the proposed restoring force characteristics, non-linear dynamic analysis was conducted, and the results were compared with those obtained by the pseudo-dynamic tests. The results showed that the RC frame (building) with no retrofitting measures applied underwent shear failure at a seismic intensity of 200 cm/s2, the threshold applied in seismic design in Korea. In contrast, in the frame (building) retrofitted with the CFT-MF system, only minor earthquake damage was observed, and even when the maximum seismic intensity (300 cm/s2) that may occur in Korean was applied, small-scale damage was observed. These results confirmed the validity of the seismic retrofitting method based on the CFT-MF system developed in the present study. The non-linear dynamic analysis and the pseudo-dynamic test showed similar results, with an average deviation of 10% or less in seismic response load and displacement.


2018 ◽  
Vol 880 ◽  
pp. 87-92
Author(s):  
Daniela Vintilă ◽  
Laura Diana Grigorie ◽  
Alina Elena Romanescu

This paper presents dynamic analysis of a three stage planetary gear reducer for operate a tower crane. Ordinary and planetary gears have been designed respecting the coaxial, neighboring and mounting conditions. Harmonic analysis has been processed to identify frequency response for displacements, strains and deformations. The aim of the study was to determine critical frequencies to avoid mechanical resonance phenomenon. The obtained results are based on the superposition method for solving the systems of differential equations resulting from the analysis with finite elements.


2020 ◽  
Vol 2020 (0) ◽  
pp. 513
Author(s):  
Masato TAKEUCHI ◽  
Kensuke HARA ◽  
Hiroshi YAMAURA

2013 ◽  
Vol 66 (4) ◽  
pp. 425-430 ◽  
Author(s):  
Jorge Luis Palomino Tamayo ◽  
Armando Miguel Awruch ◽  
Inácio Benvegnu Morsch

A numerical model using the Finite Element Method (FEM) for the nonlinear static and dynamic analysis of reinforced concrete (RC) beams, plates and shells is presented in this work. For this purpose, computer programs based on plasticity theory and with crack monitoring capabilities are developed. The static analysis of RC shells up to failure load is carried out using 9-node degenerated shell finite elements while 20-node brick finite elements are used for dynamic applications. The elasto-plastic constitutive law for concrete is coupled with a strain-rate sensitive model in order to take into account high loading rate effect when transient loading is intended. The implicit Newmark scheme with predictor and corrector phases is used for time integration of the nonlinear system of equations. In both cases, the steel reinforcement is considered to be smeared and represented by membrane finite elements. Various benchmark examples are solved with the present numerical model and comparisons with other published data are performed. For all examples, the path failure, collapse loads and failure mechanism is reproduced with great accuracy.


Sign in / Sign up

Export Citation Format

Share Document