scholarly journals Alpha—a computer program for the determination of radioisotopes by least-squares resolution of the gamma-ray spectra

1966 ◽  
Vol 42 (2) ◽  
pp. 213-218 ◽  
Author(s):  
E. Schonfeld
1978 ◽  
Vol 48 ◽  
pp. 287-293 ◽  
Author(s):  
Chr. de Vegt ◽  
E. Ebner ◽  
K. von der Heide

In contrast to the adjustment of single plates a block adjustment is a simultaneous determination of all unknowns associated with many overlapping plates (star positions and plate constants etc. ) by one large adjustment. This plate overlap technique was introduced by Eichhorn and reviewed by Googe et. al. The author now has developed a set of computer programmes which allows the adjustment of any set of contemporaneous overlapping plates. There is in principle no limit for the number of plates, the number of stars, the number of individual plate constants for each plate, and for the overlapping factor.


Author(s):  
E.A. Derkach , O.I. Guseva

Objectives: to compare the accuracy of equations F.P. Hadlock and computer programs by V.N. Demidov in determining gestational age and fetal weight in the third trimester of gestation. Materials: 328 patients in terms 36–42 weeks of gestation are examined. Ultrasonography was performed in 0–5 days prior to childbirth. Results: it is established that the average mistake in determination of term of pregnancy when using the equation of F.P. Hadlock made 12,5 days, the computer program of V.N. Demidov – 4,4 days (distinction 2,8 times). The mistake within 4 days, when using the equation of F.P. Hadlock has met on average in 23,1 % of observations, the computer program of V.N. Demidov — 65,9 % (difference in 2,9 times). The mistake more than 10 days, took place respectively in 51,7 and 8,2 % (distinction by 6,3 times). At a comparative assessment of size of a mistake in determination of fetal mass it is established that when using the equation of F.P. Hadlock it has averaged 281,0 g, at application of the computer program of V.N. Demidov — 182,5 g (distinction of 54 %). The small mistake in the mass of a fetus which isn't exceeding 200 g at application of the equation of F.P. Hadlock has met in 48,1 % of cases and the computer program of V.N. Demidov — 64,0 % (distinction of 33,1 %). The mistake exceeding 500 g has been stated in 18 % (F.P. Hadlock) and 4,3 % (V.N. Demidov) respectively (distinction 4,2 times). Conclusions: the computer program of V.N. Demidov has high precision in determination of term of a gestation and mass of a fetus in the III pregnancy.


2020 ◽  
Vol 17 (1) ◽  
pp. 87-94
Author(s):  
Ibrahim A. Naguib ◽  
Fatma F. Abdallah ◽  
Aml A. Emam ◽  
Eglal A. Abdelaleem

: Quantitative determination of pyridostigmine bromide in the presence of its two related substances; impurity A and impurity B was considered as a case study to construct the comparison. Introduction: Novel manipulations of the well-known classical least squares multivariate calibration model were explained in detail as a comparative analytical study in this research work. In addition to the application of plain classical least squares model, two preprocessing steps were tried, where prior to modeling with classical least squares, first derivatization and orthogonal projection to latent structures were applied to produce two novel manipulations of the classical least square-based model. Moreover, spectral residual augmented classical least squares model is included in the present comparative study. Methods: 3 factor 4 level design was implemented constructing a training set of 16 mixtures with different concentrations of the studied components. To investigate the predictive ability of the studied models; a test set consisting of 9 mixtures was constructed. Results: The key performance indicator of this comparative study was the root mean square error of prediction for the independent test set mixtures, where it was found 1.367 when classical least squares applied with no preprocessing method, 1.352 when first derivative data was implemented, 0.2100 when orthogonal projection to latent structures preprocessing method was applied and 0.2747 when spectral residual augmented classical least squares was performed. Conclusion: Coupling of classical least squares model with orthogonal projection to latent structures preprocessing method produced significant improvement of the predictive ability of it.


Sign in / Sign up

Export Citation Format

Share Document