Use of dual foil stripping at the Brookhaven tandem accelerator facility for improved heavy-ion performance

1974 ◽  
Vol 122 ◽  
pp. 291-293 ◽  
Author(s):  
P. Thierberger ◽  
H.E. Wegner ◽  
M. McKeown ◽  
M. Manni ◽  
I. Feigenbaum
Author(s):  
Yongtao Zhao ◽  
Rui Cheng ◽  
Yuyu Wang ◽  
Xianming Zhou ◽  
Yu Lei ◽  
...  

Abstract Recent research activities relevant to high energy density physics (HEDP) driven by the heavy ion beam at the Institute of Modern Physics, Chinese Academy of Sciences are presented. Radiography of static objects with the fast extracted high energy carbon ion beam from the Cooling Storage Ring is discussed. Investigation of the low energy heavy ion beam and plasma interaction is reported. With HEDP research as one of the main goals, the project HIAF (High Intensity heavy-ion Accelerator Facility), proposed by the Institute of Modern Physics as the 12th five-year-plan of China, is introduced.


2016 ◽  
Vol 66 (12) ◽  
pp. 1491-1499
Author(s):  
Jongwon KIM* ◽  
Woo-kang KIM ◽  
Hyun-man JANG ◽  
Youngkwon KIM ◽  
Ilkyoung SHIN ◽  
...  

2020 ◽  
Vol 232 ◽  
pp. 01005
Author(s):  
S. Shaharuddin ◽  
J. Stuchbery ◽  
E. C. Simpson ◽  
Z. K. Gan ◽  
A. C. Green ◽  
...  

Radiotherapy using protons and heavier ions is emerging as an alternative to traditional photon radiotherapy for cancer treatment. Ions have a depth-dose profile that results in high energy deposition at the end of the particle’s path, with a relatively low dosage elsewhere. However, the specifics of ion interactions with cellular biology are not yet fully understood. To study the induced biological effects of the ions on cell cultures, an external beam is required as biological specimens cannot be placed in vacuum. The Heavy Ion Accelerator Facility (HIAF) at the Australian National University hosts accelerators for a wide variety of ion-beam research applications. However, HIAF does not currently have an external beam capability. Here, we present an initial design for a radiobiological research capability at HIAF. A systems engineering approach was used to develop the architecture of the apparatus and determine the feasibility of adapting the current facilities to external beam applications. This effort included ion optics calculations, coupled to a Geant4 simulation, to characterise ion beam transitions through a thin window into the air. The beam spread, intensity distributions, and energy of proton and carbon ions were studied as a function of distance travelled from the window, as well as the effects of alternative window materials and thicknesses. It was determined that the proposed line at the HIAF would be suitable for the desired applications. Overall, this feasibility study lays the foundations of an external beam design, a simulation test framework, and the basis for a grant application for an external beam at the HIAF.


1988 ◽  
Vol 100 ◽  
Author(s):  
M. W. Bench ◽  
I. M. Robertson ◽  
M. A. Kirk

ABSTRACTTransmission electron microscopy experiments have been performed to investigate the lattice damage created by heavy-ion bombardments in GaAs. These experiments have been performed in situ by using the HVEN - Ion Accelerator Facility at Argonne National Laboratory. The ion bcorbardments (50 keV Ar+ and Kr+) and the microscopy have been carried out at temperatures rangrin from 30 to 300 K. Ion fluences ranged from 2 × 1011 to 5 × 1013 ions cm−2.Direct-inpact amorphization is observed to occur in both n-type and semi-insulating GaAs irradiated to low ion doses at 30 K and room temperature. The probability of forming a visible defect is higher for low temperature irradiations than for room temperature irradiations. The amorphous zones formed at low temperature are stable to temperatures above 250 K. Post implantation annealing is seen to occur at room temperature for all samples irradiated to low doses until eventually all visible damage disappears.


Author(s):  
V. Ceauşescu ◽  
S. Dobrescu ◽  
M. Duma ◽  
G. Indreas ◽  
M. Ivaşcu ◽  
...  

Radiocarbon ◽  
1986 ◽  
Vol 28 (2A) ◽  
pp. 522-533 ◽  
Author(s):  
T W Linick ◽  
A J T Jull ◽  
L J Toolin ◽  
D J Donahue

Radiocarbon dating at the Arizona accelerator facility has improved substantially in the last three years. Since starting to use graphite targets (see Jull et al, 1986), we have been able to obtain routinely a precision of ca ± 1% (ca 80 yr) for relatively modern material. Our routine technique of tuning and operating the tandem accelerator mass spectrometer (TAMS) and our method of calculating 14C results are discussed in detail. Data on activity ratios of oxalic acid-II/oxalic-I are presented. Examples of the wide variety of projects on which we have collaborated are given. Brief discussions of three such projects are presented for our colleagues who were unable to attend this conference: an Arizona Indian archaeologic project, a study of megafaunal extinctions, and a study of the growth of phosphorite nodules on the sea floor off the Peruvian coast.


Sign in / Sign up

Export Citation Format

Share Document