Connecting and disconnecting device for a guide line

1984 ◽  
Vol 1 (2) ◽  
pp. 197
Keyword(s):  
2019 ◽  
Vol 52 (3-4) ◽  
pp. 252-261 ◽  
Author(s):  
Xiaohua Cao ◽  
Daofan Liu ◽  
Xiaoyu Ren

Auto guide vehicle’s position deviation always appears in its walking process. Current edge approaches applied in the visual navigation field are difficult to meet the high-level requirements of complex environment in factories since they are easy to be affected by noise, which results in low measurement accuracy and unsteadiness. In order to avoid the defects of edge detection algorithm, an improved detection method based on image thinning and Hough transform is proposed to solve the problem of auto guide vehicle’s walking deviation. First, the image of lane line is preprocessed with gray processing, threshold segmentation, and mathematical morphology, and then, the refinement algorithm is employed to obtain the skeleton of the lane line, combined with Hough detection and line fitting, the equation of the guide line is generated, and finally, the value of auto guide vehicle’s walking deviation can be calculated. The experimental results show that the methodology we proposed can deal with non-ideal factors of the actual environment such as bright area, path breaks, and clutters on road, and extract the parameters of the guide line effectively, after which the value of auto guide vehicle’s walking deviation is obtained. This method is proved to be feasible for auto guide vehicle in indoor environment for visual navigation.


2015 ◽  
Vol 6 (1) ◽  
pp. 1-5
Author(s):  
Shahinul Alam ◽  
Nahiduz Saman ◽  
Monsur Hallaj Hallaj ◽  
Jahangir Ul Alam ◽  
Shoaib Momen Majumder

Relation between physicians and pharmaceutical industry is required for the benefit of the patient. But it may turn into business and overthrow the patients’ benefit. The relation might be in question at present and in future. Several questions are flowing in Bangladesh. To solve these queries we have explored the situation in developed and developing countries. The physicians and associations of pharmaceutical industries developed several ethical guidelines in those countries. They have addressed the long lasting issues on gift provided to physician, cash back, sample, industry sponsored scientific meetings, research and hospitality. There are huge restrictions to ensure the right of the patient’s e.g. limitation of inexpensive gift by the pharmaceuticals, avoiding expensive medicine instead of equally effective low priced medicine. We are lacking behind to protect the patient right properly: regulation, adherence to existing guide line, lack of guidance from statutory bodies. The current scenario is far behind the right of patient. In Bangladesh it is not yet addressed either by professionals or by pharmaceutical associations. It is the immediate need to construct a guide line for physicians and pharmaceutical industry of Bangladesh.Bangladesh Journal of Bioethics 2015 Vol.6 (1):1-5


1993 ◽  
Vol 137 ◽  
pp. 755-757
Author(s):  
P. Lemaire

AbstractProbing the interior of the Sun, a slow rotator G2 V main sequence star, and connecting the atmospheric structure to inside phenomena is one of the objectives of the SOHO mission. An overview of the helioseismology and of the coronal instruments is given. It furnishes a guide line for missions that are dedicated to the probing of stellar interiors in using microvariability and activity as tracers, such as the PRISMA study.


2011 ◽  
Vol 199-200 ◽  
pp. 870-873
Author(s):  
Hai Liang Wang ◽  
Shu Cui Cong ◽  
Bi Jun Wang ◽  
Lin Sheng Liu

According to the tunnel blasting vibration test at Kiaochow bay Cross-harbor Tunnel Guide Line Project, the regulation of the tunnel vibration velocity has been studied. Based on the analytical results, this paper finds that the change regulation of vertical, horizontal radial and tangential vibration velocity as the different distances from the work face. The tunnel vibration velocity of the rear work face is greater than the unexcavated area. The peak value of the rear work face is 2-2.5 times as large as that of the front work face, vibration velocity of the front work face attenuates gently. The paper figures out the relationship between vibration velocity and distance from sensor to the work face, which can offer a reference to similar studies.


Sign in / Sign up

Export Citation Format

Share Document