Experimental analysis of the oscillating flow characteristics for high frequency regenerators

Author(s):  
X-L. Wang ◽  
M-G. Zhao ◽  
J-H. Cai ◽  
J-T. Liang ◽  
Y. Zhou
Author(s):  
Zhen Zhang ◽  
Fabian Walter ◽  
Brian W. McArdell ◽  
Tjalling Haas ◽  
Michaela Wenner ◽  
...  

1989 ◽  
Vol 111 (3) ◽  
pp. 185-191 ◽  
Author(s):  
C. D. Bertram ◽  
C. J. Raymond ◽  
K. S. A. Butcher

To determine whether self-excited oscillations in a Starling resistor are relevant to physiological situations, a collapsible tube conveying an aqueous flow was externally pressurized along only a central segment of its unsupported length. This was achieved by passing the tube through a shorter and wider collapsible sleeve which was mounted in Starling resistor fashion in a pressure chamber. The tube size and material, and all other experimental parameters, were as used in our previous Starling resistor studies. Both low- and high-frequency self-excited oscillations were observed, but the low-frequency oscillations were sensitive to the sleeve type and length relative to unsupported distance. Pressure-flow characteristics showed multiple oscillatory modes, which differed quantitatively from those observed in comparable Starling resistors. Slow variation of driving pressure gave differing behavior according to whether the pressure was rising or falling, in accord with the hysteresis noted on the characteristics and in the tube law. The results are discussed in terms of the various possible mechanisms of collapsible tube instability, and reasons are presented for the absence of the low-frequency mode under most physiological circumstances.


2003 ◽  
pp. 539-545 ◽  
Author(s):  
K. Yuan ◽  
L. Wang ◽  
Y.K. Hou ◽  
Y. Zhou ◽  
J.T. Liang ◽  
...  

Author(s):  
Shashank R Chaurasia ◽  
RM Sarviya

An experimental analysis has been carried out to investigate the thermal and friction factor characteristics of fluid flow in a tube with double strip helical screw tape (DS-HST) inserts with different values of twist ratio and compared with single strip helical screw tape inserts and plain tube. Water is used as a working fluid at different flow rates with constant heat flux conditions. CFD analysis is also carried out to visualize thermal and fluid flow characteristics of fluid flow in tube with inserts. Experimental results have showed that Nusselt number and friction factor have attained excellent enhancement with double strip helical screw tape inserts in the range of flow rates than single strip helical screw tape inserts at the value of twist ratio 1.5. Correlation is also developed for Nusselt number with a range of Reynolds number, twist ratio and number of strips. Moreover, the performance ratio has attained maximum value at twist ratio of 2.5 with high values of flow rate. It is concluded that DS-HST is able to attain enhancement in the efficiency of heat exchanger, causing a reduction in size for thermal applications.


Author(s):  
Tao Wang ◽  
Maosheng Wang ◽  
Youliang Su ◽  
Song Mu ◽  
Kai Jing ◽  
...  

2020 ◽  
Vol 85 ◽  
pp. 108624
Author(s):  
F. Felis ◽  
S. Tomas ◽  
A. Vallet ◽  
M. Amielh ◽  
F. Anselmet

Sign in / Sign up

Export Citation Format

Share Document