Influence of the thermo-electric coupling on the heat transfer in cylindrical annulus with a dielectric fluid under microgravity

2016 ◽  
Vol 129 ◽  
pp. 88-94 ◽  
Author(s):  
Vadim Travnikov ◽  
Olivier Crumeyrolle ◽  
Innocent Mutabazi
2018 ◽  
Vol 5 (7) ◽  
pp. 180125 ◽  
Author(s):  
Liang Zheng ◽  
Jianfei Wan ◽  
Yunjiang Long ◽  
Helin Fu ◽  
Jing Zheng ◽  
...  

Generally minimally invasive surgery is performed using an endoscope and other instruments including electrosurgical units (ESUs), and the adhesion of tissue to electrodes is a major concern. The mechanism governing this tissue sticking, especially the influence of high-frequency electric field, is still unclear. In this study, the effect of high-frequency electric field on the tissue sticking upon electrodes was investigated. The electrosurgical cutting test was performed on ex vivo fresh porcine liver under blend mode using a monopolar ESU. A heat-adherence test without electric field was used as a control. For the control group, the electrode was heated and maintained at a certain temperature and directly in contact with porcine liver. Both sticking tissues obtained from these two tests are partially carbonized porcine liver tissue, but their microstructure and bonding with electrode are obviously different. The sticking tissue formed just under heat is composed of biggish nanoparticles of different sizes which are loosely aggregated and has a weak bonding with the electrode, while the sticking tissue from the electrosurgical cutting test consists of tightly packed fine nanoparticles of equable size as a result of thermo-electric coupling and has a strong bonding with the electrode. Obviously, high-frequency electric field plays an extremely important role in the formation of the sticking tissue. It is the thermo-electric coupling that underlies the function of minimally invasive electrosurgical devices, and the effect of high-frequency electric field cannot be ignored in the tissue sticking study and anti-sticking strategies.


Author(s):  
Lung-Yi Lin ◽  
Yeau-Ren Jeng ◽  
Chi-Chuan Wang

This study presents convective single-phase and boiling two-phase heat transfer performance of HFE-7100 coolant within multi-port microchannel heat sinks. The corresponding hydraulic diameters are 450 and 237 μm, respectively. For single-phase results, the presence of inlet/outlet locations inevitably gives rise to considerable increase of total pressure drop of a multi-port microchannel heat sink whereas has virtually no detectable influence on overall heat transfer performance provided that the effect of entrance has been accounted for. The convective boiling heat transfer coefficient for the HFE-7100 coolant shows a tremendous drop when vapor quality is above 0.6. For Dh = 450 μm, it is found that the mass flux effect on the convective heat transfer coefficient is rather small.


1983 ◽  
Vol 105 (1) ◽  
pp. 117-123 ◽  
Author(s):  
P. Vasseur ◽  
L. Robillard ◽  
B. Chandra Shekar

The effect of density inversion on steady natural convection heat transfer of cold water, between two horizontal concentric cylinders of gap width, L, is studied numerically. Water near its freezing point is characterized by a density maximum at 4°C. Numerical solutions are obtained for cylinders with nonlinear Rayleigh numbers RA ranging from 2 × 103 to 7.6 × 104, a radius ratio 1.75 ≤ ra ≤ 2.6 and an inversion parameter γ, relating the temperature for maximum density with the cavity wall temperatures, between −2 and 2. The results obtained are presented graphically in the form of streamline and isotherm contour plots. The heat transfer characteristics, velocity profiles, and local and overall Nusselt numbers are studied. The results of the present study were found qualitatively valid when compared with an experimental investigation carried out in the past.