scholarly journals The European Standard Reference Method systematically underestimates particulate matter in stack emissions

2021 ◽  
Vol 12 ◽  
pp. 100133
Author(s):  
Egill Antonsson ◽  
Jens Cordes ◽  
Benno Stoffels ◽  
Dominik Wildanger
2014 ◽  
Vol 98 ◽  
pp. 271-282 ◽  
Author(s):  
Yolanda González-Castanedo ◽  
Teresa Moreno ◽  
Rocío Fernández-Camacho ◽  
Ana María Sánchez de la Campa ◽  
Andrés Alastuey ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (23) ◽  
pp. 6819
Author(s):  
Brigida Alfano ◽  
Luigi Barretta ◽  
Antonio Del Giudice ◽  
Saverio De Vito ◽  
Girolamo Di Francia ◽  
...  

The concerns related to particulate matter’s health effects alongside the increasing demands from citizens for more participatory, timely, and diffused air quality monitoring actions have resulted in increasing scientific and industrial interest in low-cost particulate matter sensors (LCPMS). In the present paper, we discuss 50 LCPMS models, a number that is particularly meaningful when compared to the much smaller number of models described in other recent reviews on the same topic. After illustrating the basic definitions related to particulate matter (PM) and its measurements according to international regulations, the device’s operating principle is presented, focusing on a discussion of the several characterization methodologies proposed by various research groups, both in the lab and in the field, along with their possible limitations. We present an extensive review of the LCPMS currently available on the market, their electronic characteristics, and their applications in published literature and from specific tests. Most of the reviewed LCPMS can accurately monitor PM changes in the environment and exhibit good performances with accuracy that, in some conditions, can reach R2 values up to 0.99. However, such results strongly depend on whether the device is calibrated or not (using a reference method) in the operative environment; if not, R2 values lower than 0.5 are observed.


2016 ◽  
Vol 18 (12) ◽  
pp. 1561-1571
Author(s):  
Sonya Beccaceci ◽  
Richard J. C. Brown ◽  
David M. Butterfield ◽  
Peter M. Harris ◽  
René P. Otjes ◽  
...  

The results of field trial campaign to validate the European standard measurement method for anions and cations in ambient particulate matter are presented.


2010 ◽  
Vol 15 (9) ◽  
pp. 493-502 ◽  
Author(s):  
Richard J. C. Brown ◽  
Kym E. Jarvis ◽  
Benoit A. Disch ◽  
Sharon L. Goddard ◽  
Elke Adriaenssens ◽  
...  

2021 ◽  
Author(s):  
Karri Saarnio ◽  
Mika Vestenius ◽  
Katriina Kyllönen

The National Reference Laboratory for Air Quality (NRL) ensures the high quality of air quality measurements in Finland by organising audits and intercomparison campaigns. In this project, the conformity of the particulate matter measurements was evaluated with a particular focus on the measurement used for calculating the average exposure index (AEI) of Finland. The representativity and applicability of the AEI measurements made at the Kallio station in Helsinki were evaluated. It was noticed that the results of the Kallio measurement represent well the average fine particle (PM2.5) concentrations and the yearly based trend of fine particles in Finland. In addition, the yearly average concentrations of fine particles have been smaller than the AEI limit value of 8.5 µg/m3, at all individual urban background stations in Finland since year 2015. The measurement results made with the PM monitor used for AEI measurement, i.e. TEOM 1405 analyser at the Kallio station, were compared to the results from the reference method that follows the standard SFS-EN 12341:2014. It was noticed that the uncertainty requirement of 25% was reached and therefore the quality of the measurement is sufficient to use it for the calculation of AEI. However, the fine particle concentrations were generally very low and therefore the requirements given in the standard SFS-EN 16450:2017 for an intercomparison against the reference method were not perfectly fulfilled. This report presents also results from intercomparison measurements made for automated continuous measurement systems (AMS). At the Virolahti station and at the Mäkelänkatu station in Helsinki, PM10 and PM2.5 measurements were compared. In Kuopio and in Lahti, intercomparison measurements were made for PM2.5 only. Based on the results from these intercomparisons, the calibration coefficients both for PM10 and PM2.5 were defined for the first time in Finland for a FIDAS 200 analyser that is a new PM monitor in the Finnish market. It was concluded that FIDAS 200 analysers can be used for the PM measurements in Finland when the calibration coefficients are applied for the data; however, one must note that the presented calibration coefficients do not fulfil the requirements given for the demonstration of equivalence (DoE). Nevertheless, these coefficients are recommended to be used until the official coefficients will be delivered from the next DoE campaign. Two AMS (SHARP 5030 and TEOM 1405) were compared to the reference method for the measurements of PM10 and PM2,5 in Virolahti and in Helsinki, respectively. It was revealed that the calibration coefficients based on the DoE in Kuopio (2014–2015) do not always fit ideally at different locations and seasons due to differences in the environmental characteristics of the measurement sites. Therefore, NRL recommends that DoE should be organised every five years and in between the DoE’s so called ongoing-intercomparison measurements should be carried out continuously. In the ongoing-intercomparison, suitability of the calibration coefficients from DoE will be verified in different locations with varying environmental characteristics. The ongoing-intercomparison campaigns should take place at one site from a half a year to one year and after that, the campaign should continue at a different location similarly. This would ensure that the influence of seasonal differences to the suitability of coefficients will be verified at each measurement site.


2020 ◽  
Vol 71 (1) ◽  
pp. 83-87
Author(s):  
Elena Bucur ◽  
Radu Motisan ◽  
Andrei Vasile ◽  
Gheorghita Tanase ◽  
Luoana Florentina Pascu ◽  
...  

The paper presents the test results regarding the evaluation of the accuracy of the PM2.5 and PM10 particulate matter concentration measurement performed with the uRADMonitor A3 fixed air quality monitoring station produced by SC MAGNASCI SRL. The procedure involves the calculation of the accuracy elements: trueness and precision, based on the experimental data obtained by measuring the concentration of particulate matter using the tested analysers in parallel with the reference method, SR EN 12341: 2014, and analysis of data series by Pearson correlation and linear regression.