A new full body low-dose x-ray technique is an alternative to conventional “shunt series” in patients with ventriculoperitoneal shunt dysfunction

2007 ◽  
Vol 25 (6) ◽  
pp. 702-703 ◽  
Author(s):  
Benoit B. Schaller ◽  
Aristomenis K. Exadaktylos ◽  
Robert H. Andres ◽  
Harald M. Bonel
2009 ◽  
Vol 52 (2) ◽  
pp. 77-79 ◽  
Author(s):  
Fatih Serhat Erol ◽  
Bekir Akgun

Proximal migration of the distal end of a ventriculoperitoneal shunt has been observed much more rarely than other numerous shunt-related complications. Subgaleal migration of the peritoneal end is one of the samples. In the preset report we have discussed a case of subgaleal migration of the peritoneal end detected as a result of the examinations performed for shunt dysfunction. There was ventricular dilatation on CT scan of the brain. X-ray examinations confirmed proper ventricular catheter and shunt valve placement but a complete migration of distal (peritoneal) catheter into the subgaleal space. Then the patient’s shunt was revised. When our case and the literature were examined, we observed that this complication was frequently encountered during the first postoperative months, in the pediatric ages and in patients with advanced hydrocephalus. Besides, we have detected that the peritoneal catheters had tendency to migration into the subgaleal tissues similar to pre-insertion forms of the preoperatively original packages.


2020 ◽  
Vol 58 (3) ◽  
pp. 391-397
Author(s):  
Taylor A. Docter ◽  
Bhavik H. Patel ◽  
Jesse J. Brennan ◽  
Edward M. Castillo ◽  
Roland R. Lee ◽  
...  

2014 ◽  
Vol 9 (1) ◽  
pp. 45-49
Author(s):  
Essam A. Elgamal ◽  
Waleed R. Murshid ◽  
Sherif M.F. Elwatidy ◽  
Zain B. Jamjoom

2018 ◽  
Vol 116 ◽  
pp. e273-e277 ◽  
Author(s):  
Liat Ben-Sira ◽  
Shelly I. Shiran ◽  
Li-tal Pratt ◽  
Ronit Precel ◽  
Dror Ovadia ◽  
...  

Author(s):  
T. Oikawa ◽  
N. Mori ◽  
T. Katoh ◽  
Y. Harada ◽  
J. Miyahara ◽  
...  

The “Imaging Plate”(IP) is a highly sensitive image recording plate for X-ray radiography. It has been ascertained that the IP has superior properties and high practicability as an image recording material in a TEM. The sensitivity, one of the properties, is about 3 orders higher than that of conventional photo film. The IP is expected to be applied to low dose techniques. In this paper, an estimation of the quantum noise on the TEM image which appears in case of low electron dose on the IP is reported.In this experiment, the JEM-2000FX TEM and an IP having the same size as photo film were used.Figure 1 shows the schematic diagram of the total system including the TEM used in this experiment. In the reader, He-Ne laser light is scanned across the IP, then blue light is emitted from the IP.


Author(s):  
John A. Hunt ◽  
Richard D. Leapman ◽  
David B. Williams

Interactive MASI involves controlling the raster of a STEM or SEM probe to areas predefined byan integration mask which is formed by image processing, drawing or selecting regions manually. EELS, x-ray, or other spectra are then acquired while the probe is scanning over the areas defined by the integration mask. The technique has several advantages: (1) Low-dose spectra can be acquired by averaging the dose over a great many similar features. (2) MASI can eliminate the risks of spatial under- or over-sampling of multiple, complicated, and irregularly shaped objects. (3) MASI is an extremely rapid and convenient way to record spectra for routine analysis. The technique is performed as follows:Acquire reference imageOptionally blank beam for beam-sensitive specimensUse image processor to select integration mask from reference imageCalculate scanning path for probeUnblank probe (if blanked)Correct for specimen drift since reference image acquisition


Author(s):  
T.W. Jeng ◽  
W. Chiu

With the advances in preparing biological materials in a thin and highly ordered form, and in maintaining them hydrated under vacuum, electron crystallography has become an important tool for biological structure investigation at high resolution (1,2). However, the electron radiation damage would limit the capability of recording reflections with low intensities in an electron diffraction pattern. It has been demonstrated that the use of a low temperature stage can reduce the radiation damage effect and that one can expose the specimen with a higher dose in order to increase the signal contrast (3). A further improvement can be made by selecting a proper photographic emulsion. The primary factors in evaluating the suitability of photographic emulsion for recording low dose diffraction patterns are speed, fog level, electron response at low electron exposure, linearity, and usable range of exposure. We have compared these factors with three photographic emulsions including Kodak electron microscopic plate (EMP), Industrex AA x-ray film (AA x-ray) and Kodak nuclear track film (NTB3).


2021 ◽  
pp. 2004391
Author(s):  
Youbin Li ◽  
Mingyang Jiang ◽  
Zhiming Deng ◽  
Songjun Zeng ◽  
Jianhua Hao
Keyword(s):  
Low Dose ◽  
X Ray ◽  

Dose-Response ◽  
2017 ◽  
Vol 15 (1) ◽  
pp. 155932581769753 ◽  
Author(s):  
Shuji Kojima ◽  
Mitsutoshi Tsukimoto ◽  
Noriko Shimura ◽  
Hironobu Koga ◽  
Akishisa Murata ◽  
...  

There is considerable evidence from experimental studies in animals, as well as from clinical reports, that low-dose radiation hormesis is effective for the treatment of cancer and ulcerative colitis. In this study, we present 3 case reports that support the clinical efficacy of low-dose radiation hormesis in patients with these diseases. First, a patient with prostate cancer who had undergone surgical resection showed a subsequent increase in prostate-specific antigen (PSA). His PSA value started decreasing immediately after the start of repeated low-dose X-ray irradiation treatment and remained low thereafter. Second, a patient with prostate cancer with bone metastasis was treated with repeated low-dose X-ray irradiation. His PSA level decreased to nearly normal within 3 months after starting the treatment and remained at the low level after the end of hormesis treatment. His bone metastasis almost completely disappeared. Third, a patient with ulcerative colitis showed a slow initial response to repeated low-dose irradiation treatment using various modalities, including drinking radon-containing water, but within 8 months, his swelling and bleeding had completely disappeared. After 1 year, the number of bowel movements had become normal. Interest in the use of radiation hormesis in clinical practice is increasing, and we hope that these case reports will encourage further clinical investigations.


Sign in / Sign up

Export Citation Format

Share Document