Progress in studying the fretting wear/corrosion of nuclear steam generator tubes

2020 ◽  
Vol 144 ◽  
pp. 107556 ◽  
Author(s):  
Xianglong Guo ◽  
Ping Lai ◽  
Ling Li ◽  
Lichen Tang ◽  
Lefu Zhang
Wear ◽  
2003 ◽  
Vol 255 (7-12) ◽  
pp. 1198-1208 ◽  
Author(s):  
Young-Ho Lee ◽  
Hyung-Kyu Kim ◽  
Hong-Deok Kim ◽  
Chi-Yong Park ◽  
In-Sup Kim

2006 ◽  
Vol 326-328 ◽  
pp. 1251-1254 ◽  
Author(s):  
Chi Yong Park ◽  
Jeong Keun Lee

Fretting wear generated by flow induced vibration is one of the important degradation mechanisms of steam generator tubes in the nuclear power plants. Understanding of tube wear characteristics is very important to keep the integrity of the steam generator tubes to secure the safety of the nuclear power plants. Experimental examination has been performed for the purpose of investigating the impact fretting. Test material is alloy 690 tube and 409 stainless steel tube supports. From the results of experiments, wear scar progression is investigated in the case of impact-fretting wear test of steam generator tubes under plant operating conditions such as pressure of 15MPa, high temperature of 290C and low dissolved oxygen. Hammer imprint that is actual damaged wear pattern, has been observed on the worn surface. From investigation of wear scar pattern, wear mechanism was initially the delamination wear due to cracking the hard oxide film and finally transferred to the stable impact-fretting pattern.


2008 ◽  
Vol 130 (4) ◽  
Author(s):  
Xinjian Duan ◽  
Michael J. Kozluk ◽  
Sandra Pagan ◽  
Brian Mills

Aging steam generator tubes have been experiencing a variety of degradations such as pitting, fretting wear, erosion-corrosion, thinning, cracking, and denting. To assist with steam generator life cycle management, some defect-specific flaw models have been developed from burst pressure testing results. In this work, an alternative approach; heterogeneous finite element model (HFEM), is explored. The HFEM is first validated by comparing the predicted failure modes and failure pressure with experimental measurements of several tubes. Several issues related to the finite element analyses such as temporal convergence, mesh size effect, and the determination of critical failure parameters are detailed. The HFEM is then applied to predict the failure pressure for use in a fitness-for-service condition monitoring assessment of one removed steam generator tube. HFEM not only calculates the correct failure pressure for a variety of defects, but also predicts the correct change of failure mode. The Taguchi experimental design method is also applied to prioritize the flaw dimensions that affect the integrity of degraded steam generator tubes such as the defect length, depth, and width. It has been shown that the defect depth is the dominant parameter controlling the failure pressure. The failure pressure varies almost linearly with defect depth when the defect length is greater than two times the tube diameter. An axial slot specific flaw model is finally developed.


2005 ◽  
Vol 297-300 ◽  
pp. 1418-1423 ◽  
Author(s):  
Chi Yong Park ◽  
Yong Sung Lee ◽  
Myung Hwan Boo

In steam generators of nuclear power plants, flow-induced vibration (FIV) can lead to tube damage by fretting-wear occurred due to impact and sliding movement between the tubes and their supports. There have been many studies and test results on wear damage of steam generator tubes but they were not reflected the mechanical and chemical conditions accurately. KEPRI nuclear power laboratory developed a wear test system, which is able to control the motion of impact and sliding simultaneously in the pressurized high temperature water-chemistry conditions. Some wear tests were performed to verify the stable operation for the wear test. This wear test system with new concepts was described briefly, and some data for verifying its performance have been shown in the cases of the selected some test results. In the test, Alloy 690 was used for tube materials and 409 stainless steel for support plates. A little data deviation was obtained and stability of system operation was investigated.


2010 ◽  
Vol 47 (5) ◽  
pp. 449-456 ◽  
Author(s):  
Ki-Wahn RYU ◽  
Chi-Yong PARK ◽  
Hyung-Nam KIM ◽  
Huinam RHEE

Author(s):  
Mitch Hokazono ◽  
Clayton T. Smith

Integral light-water reactor designs propose the use of steam generators located within the reactor vessel. Steam generator tubes in these designs must withstand external pressure loadings to prevent buckling, which is affected by material strength, fabrication techniques, chemical environment and tube geometry. Experience with fired tube boilers has shown that buckling in boiler tubes is greatly alleviated by controlling ovality in bends when the tubes are fabricated. Light water reactor steam generator pressures will not cause a buckling problem in steam generators with reasonable fabrication limits on tube ovality and wall thinning. Utilizing existing Code rules, there is a significant design margin, even for the maximum differential pressure case. With reasonable bend design and fabrication limits the helical steam generator thermodynamic advantages can be realized without a buckling concern. This paper describes a theoretical methodology for determining allowable external pressure for steam generator tubes subject to tube ovality based on ASME Section III Code Case N-759-2 rules. A parametric study of the results of this methodology applied to an elliptical cross section with varying wall thicknesses, tube diameters, and ovality values is also presented.


2013 ◽  
Vol 135 (3) ◽  
Author(s):  
Téguewindé Sawadogo ◽  
Njuki Mureithi

Having previously verified the quasi-steady model under two-phase flow laboratory conditions, the present work investigates the feasibility of practical application of the model to a prototypical steam generator (SG) tube subjected to a nonuniform two-phase flow. The SG tube vibration response and normal work-rate induced by tube-support interaction are computed for a range of flow conditions. Similar computations are performed using the Connors model as a reference case. In the quasi-steady model, the fluid forces are expressed in terms of the quasi-static drag and lift force coefficients and their derivatives. These forces have been measured in two-phase flow over a wide range of void fractions making it possible to model the effect of void fraction variation along the tube span. A full steam generator tube subjected to a nonuniform two-phase flow was considered in the simulations. The nonuniform flow distribution corresponds to that along a prototypical steam-generator tube based on thermal-hydraulic computations. Computation results show significant and important differences between the Connors model and the two-phase flow based quasi-steady model. While both models predict the occurrence of fluidelastic instability, the predicted pre-instability and post instability behavior is very different in the two models. The Connors model underestimates the flow-induced negative damping in the pre-instability regime and vastly overestimates it in the post instability velocity range. As a result the Connors model is found to underestimate the work-rate used in the fretting wear assessment at normal operating velocities, rendering the model potentially nonconservative under these practically important conditions. Above the critical velocity, this model largely overestimates the work-rate. The quasi-steady model on the other hand predicts a more moderately increasing work-rate with the flow velocity. The work-rates predicted by the model are found to be within the range of experimental results, giving further confidence to the predictive ability of the model. Finally, the two-phase flow based quasi-steady model shows that fluidelastic forces may reduce the effective tube damping in the pre-instability regime, leading to higher than expected work-rates at prototypical operating velocities.


Sign in / Sign up

Export Citation Format

Share Document