Real-time emergency load shedding for power system transient stability control: A risk-averse deep learning method

2021 ◽  
pp. 118221
Author(s):  
Jizhe Liu ◽  
Yuchen Zhang ◽  
Ke Meng ◽  
Zhao Yang Dong ◽  
Yan Xu ◽  
...  
Author(s):  
Xin Zhang ◽  
Yawen Wang ◽  
Penghai Xie ◽  
Sajia Lin ◽  
Hanxing Luo ◽  
...  

Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3066 ◽  
Author(s):  
Hongbo Shao ◽  
Yubin Mao ◽  
Yongmin Liu ◽  
Wanxun Liu ◽  
Sipei Sun ◽  
...  

Controlled islanding has been proposed as a last resort action to stop blackouts from happening when all standard methods have failed. Successful controlled islanding has to deal with three important issues: when, and where to island, and the evaluation of the dynamic stability in each island after islanding. This paper provides a framework for preventing wide-area blackouts using wide area measurement systems (WAMS), which consists of three stages to execute a successful islanding strategy. Normally, power system collapses and blackouts occur shortly after a cascading outage stage. Using such circumstances, an adapted single machine equivalent (SIME) method was used online to determine transient stability before blackout was imminent, and was then employed to determine when to island based on transient instability. In addition, SIME was adopted to assess the dynamic stability in each island after islanding, and to confirm that the chosen candidate island cutsets were stable before controlled islanding was undertaken. To decide where to island, all possible islanding cutsets were provided using the power flow (PF) tracing method. SIME helped to find the best candidate islanding cutset with the minimal PF imbalance, which is also a transiently stable islanding strategy. In case no possible island cutset existed, corresponding corrective actions such as load shedding and critical generator tripping, were performed in each formed island. Finally, an IEEE 39-bus power system with 10 units was employed to test this framework for a three-stage controlled islanding strategy to prevent imminent blackouts.


2014 ◽  
Vol 986-987 ◽  
pp. 1286-1290
Author(s):  
Jin Li ◽  
Ya Min Pi ◽  
Hui Yuan Yang

In this paper, the series converters of Distributed Power Flow Controller are the main object of study. Its mechanism of suppressing power system oscillations is studied by theoretical analysis and formula derivation, which relies on a single-machine infinite-bus power system, installed the series converters. Then based on the mechanism, adopting the classic PI control and the damping controller, designed the transient stability control loop for the series converters. Finally, simulations performed by PSCAD/EMTDC, the results show that DPFC device can effectively suppress oscillation and improve system stability.


Author(s):  
Yu Cai ◽  
Wei Li ◽  
Bao Zhang ◽  
Wenjian Wu ◽  
Deren Sheng ◽  
...  

Fast valving of ultra-supercritical unit has great effects on over-speed prevention, load-shedding control, transient stability analysis of electrical system and other security problems. The purpose of fast valving is to maintain the stability of power system once fault or load shedding of unit occurs in the electric power system. Therefore, it is of great significance to study the reliability of fast valving for ultra-supercritical unit. In this paper, the KU ( short shedding) logic condition of SIEMENS T3000 system is analyzed as the research object of fast valving. The unit can be avoided over speed by monitoring the unit load and fast valving under faulty grid conditions based on the KU control. A series of measures will be taken after KU is triggered, for instance the governing valving will be closed quickly and the DEH (digital electro-hydraulic) control of the steam turbine will be switched to speeding control mode. On the other hand, the unit will return to normal operation if the transient fault of power grid disappears. The key contributions of this thesis include three parts: Firstly, based on the analysis of control characteristics of ultra-supercritical unit and protective logic and triggered conditions of KU function, a novel dynamic model by coupling the fast valving of steam turbine and the transient stability of generator is established by applying the PSCAD software. Then, the dynamic response process of ultra-supercritical unit is simulated and calculated by adopting the coupling dynamic model when KU function is triggered. Also the influence factors and reliability of fast valving are analyzed under transient fault conditions. Finally, two optimized measures by increasing the time delay and the speed of quantitative judgment are put forward to reduce risks and avoid the misoperation of signal distortion which may be caused by the power transmitter under transient fault conditions. The results of this study can not only help to evaluate the reliability of fast valving function scientifically in power grid transient fault, but also guide the technicians to analyze the stability of the power grid.


Author(s):  
P. F. Le Roux ◽  
R.C. Bansal

An electrical network constantly faces unforeseen events such as faults on lines, loss of load and loss of generation. Under-frequency load shedding and generator tripping are traditional methods used to stabilise a network when a transient fault occurs. These methods will prevent any network instability by shedding load or tripping the most critical generator at a calculated time when required. By executing these methods, the network can be stabilised in terms of balancing the generation and the load of a power system. A hybrid control scheme is proposed where the traditional methods are combined to reduce the stress levels exerted on the network and to minimise the load to be shed.


2020 ◽  
Vol 12 (34) ◽  
pp. 38192-38201 ◽  
Author(s):  
Lei Yang ◽  
Yunfei Wang ◽  
Zhibin Zhao ◽  
Yanjie Guo ◽  
Sicheng Chen ◽  
...  