Optimization of data center cooling efficiency using reduced order flow modeling within a flow network modeling approach

2017 ◽  
Vol 124 ◽  
pp. 929-939 ◽  
Author(s):  
Kamran Fouladi ◽  
Aaron P. Wemhoff ◽  
Luis Silva-Llanca ◽  
Kayvan Abbasi ◽  
Alfonso Ortega
Author(s):  
K. Fouladi ◽  
A. P. Wemhoff ◽  
L. Silva-Llanca ◽  
A. Ortega

Much of the energy use by data centers is attributed to the energy needed to cool the data centers. Thus, improving the cooling efficiency and thermal management of data centers can translate to direct and significant economic benefits. However, data centers are complex systems containing a significant number of components or sub-systems (e.g., servers, fans, pumps, and heat exchangers) that must be considered in any synergistic data center thermal efficiency optimization effort. The Villanova Thermodynamic Analysis of Systems (VTAS) is a flow network tool for performance prediction and design optimization of data centers. VTAS models the thermodynamics, fluid mechanics, and heat transfer inherent to an entire data center system, including contributions by individual servers, the data center airspace, and the HVAC components. VTAS can be employed to identify the optimal cooling strategy among various alternatives by computing the exergy destruction of the overall data center system and the various components in the system for each alternative. Exergy or “available energy” has been used to identify components and wasteful practices that contribute significantly in cooling inefficiency of data centers including room air recirculation — premature mixing of hot and cold air streams in a data center. Flow network models are inadequate in accurately predicting the magnitude of airflow exergy destruction due to simplifying assumptions and the three-dimensional nature of the flow pattern in the room. On the other hand, CFD simulations are time consuming, making them impractical for iterative-based design optimization approaches. In this paper we demonstrate a hybrid strategy, in which a proper orthogonal decomposition (POD) based airflow modeling approach developed from CFD simulation data is implemented in VTAS for predicting the room airflow exergy destruction. The reduced order POD tool in VTAS provides higher accuracy than 1-D flow network models and is computationally more efficient than 3-D CFD simulations. The present VTAS – POD tool has been applied to a data center cell to illustrate the use of exergy destruction minimization as an objective function for data center thermal efficiency optimization.


AIAA Journal ◽  
2008 ◽  
Vol 46 (3) ◽  
pp. 664-672 ◽  
Author(s):  
Howard H. Hamilton ◽  
Andrew J. Kurdila ◽  
Anand K. Jammulamadaka

AIAA Journal ◽  
10.2514/2.912 ◽  
2000 ◽  
Vol 38 (12) ◽  
pp. 2219-2232 ◽  
Author(s):  
Jeonghwan Ko ◽  
Andrew J. Kurdila ◽  
Othon K. Rediniotis

Author(s):  
Laurent M. Billet ◽  
Christopher M. Healey ◽  
James W. VanGilder ◽  
Zachary M. Pardey

The efficient control of cooling for data centers is an issue of broad economic importance due to the significant energy consumption of data centers. Many solutions attempt to optimize the control of the cooling equipment with temperature, pressure, or airflow sensors. We propose a simulation-based approach to optimize the cooling energy consumption and show how this approach can be implemented with simple power-consumption models. We also provide a real-life case study to demonstrate how energy saving cooling setpoints can be found using calibrated simulations and smooth metamodels of the system.


AIAA Journal ◽  
2000 ◽  
Vol 38 ◽  
pp. 2219-2232 ◽  
Author(s):  
Jeonghwan Ko ◽  
Andrew J. Kurdila ◽  
Othon K. Rediniotis

Author(s):  
Stephen Paul Linder ◽  
Jim Van Gilder ◽  
Yan Zhang ◽  
Enda Barrett

Abstract Efficient cooling of data center infrastructure is an important way to reduce total energy consumption. Containment, with separation of hot and cold airflows has allowed significant increase in efficiencies. However, balancing the airflow, so that IT equipment in an aisle only receives the cooling airflow that that aisle needs is still often not done. We propose a new architecture where IT racks are clustered together with shared hot aisles ducted to a common ceiling plenum. Each aisle has an actively controlled damper used to balance the airflow to the cooling infrastructure. Using a differential air pressure sensor in each aisle and an algorithm designed to balance the flow network, we minimize the cooling airflow and maximize cooling efficiency.