Influence of heat release rate and wall heat-blocking effect on the thermal plume ejected from compartment fire

2018 ◽  
Vol 139 ◽  
pp. 585-597
Author(s):  
Lei Miao ◽  
Cheuk Lun Chow
2019 ◽  
pp. 326-326
Author(s):  
Olivier Zatao-Samedi ◽  
Abbo Oumarou ◽  
Jean M’Boliguipa ◽  
Mvogo Onguene ◽  
Ruben Mouangue

Many factors have an influence on the development of compartment fire notably on its heat release rate as well as on its capability to propagate and become a flashover situation. The main element which rapidly conveys fire from a compartment to another is hot smoke flowing out through openings of the compartment source of fire. The present work aims to experiment the impact of the variation of heat release rate of the source on the behaviour of fire. So, five fire tests with different heat release rates were thus carried out in a reduced scale room. Temperature of burned gases inside the room, were measured during tests by sensors connected to a data acquisition system. Results revealed that temperature of burned gases as well as its content in carbon monoxide, evolves differently according to two ranges of the incoming air/outgoing gases ratio. The first range of which the ratio is lower than 2, corresponds to the case where both parameters decrease rapidly. The second range of which the ratio is higher than 2, corresponds to the case where both parameters decrease moderately. The transition from the first to the second range, points out the passing from the ventilation-controlled fire to the fuel-controlled fire. A relation expressing the variation of the mass flow rate of outgoing burned gases according to the heat release rate of the fire source has been given.


2008 ◽  
Vol 18 (2) ◽  
pp. 111-124 ◽  
Author(s):  
C. Chen ◽  
L. Qu ◽  
Y. X. Yang ◽  
G. Q. Kang ◽  
W. K. Chow

2021 ◽  
Vol 11 (7) ◽  
pp. 3247
Author(s):  
Dong Hwan Kim ◽  
Chi Young Lee ◽  
Chang Bo Oh

In this study, the effects of discharge area and atomizing gas type in a twin-fluid atomizer on heptane pool fire-extinguishing performance were investigated under the heat release rate conditions of 1.17 and 5.23 kW in an enclosed chamber. Large and small full cone twin-fluid atomizers were prepared. Nitrogen and air were used as atomizing gases. With respect to the droplet size of water mist, as the water and air flow rates decreased and increased, respectively, the Sauter mean diameter (SMD) of the water mist decreased. The SMD of large and small atomizers were in the range of approximately 12–60 and 12–49 μm, respectively. With respect to the discharge area effect, the small atomizer exhibited a shorter extinguishing time, lower peak surface temperature, and higher minimum oxygen concentration than the large atomizer. Furthermore, it was observed that the effect of the discharge area on fire-extinguishing performance is dominant under certain flow rate conditions. With respect to the atomizing gas type effect, nitrogen and air appeared to exhibit nearly similar extinguishing times, peak surface temperatures, and minimum oxygen concentrations under most flow rate conditions. Based on the present and previous studies, it was revealed that the effect of atomizing gas type on fire-extinguishing performance is dependent on the relative positions of the discharged flow and fire source.


Fuel ◽  
2021 ◽  
Vol 288 ◽  
pp. 119656
Author(s):  
Robbert Willems ◽  
Frank Willems ◽  
Niels Deen ◽  
Bart Somers

Sign in / Sign up

Export Citation Format

Share Document