A microalga is better than a commercial lipid emulsion at enhancing live feeds for an ornamental marine fish larva

Aquaculture ◽  
2020 ◽  
Vol 523 ◽  
pp. 735203
Author(s):  
Alexander J. Basford ◽  
Benjamin Mos ◽  
David S. Francis ◽  
Giovanni M. Turchini ◽  
Camille A. White ◽  
...  
1989 ◽  
Vol 30 (5) ◽  
pp. 449-457 ◽  
Author(s):  
K. Ivancev ◽  
A. Lunderquist ◽  
A. Isaksson ◽  
P. Hochbergs ◽  
A. Wretlind

A new iodinated lipid emulsion, Intraiodol, for which animal studies have indicated better tolerance than for other iodinated lipid emulsions, was tested in 15 patients with malignant lesions, and in one patient with focal nodular hyperplasia. Repeated CT scans of the liver and spleen and blood tests were performed for 24 hours after intravenous injection of Intraiodol. The uptake of Intraiodol in the liver (peak mean 28.6 HU) was higher than in the spleen (peak mean 21.8 HU). The uptake of Intraiodol in malignant lesions was minimal (peak mean 2.8 HU). The detection rate of hepatic lesions was equal to or better than that achieved by US, CT, and/or CT angiography. However, liver uptake of Intraiodol was low in 2 patients with severe fatty infiltration. Intraiodol produced vascular enhancement up to one hour after injection since it was eliminated slowly from the circulation. The observed adverse reactions consisted of temporary metallic taste in 5 of the patients, fever and exacerbation of back pain in one patient, and transient thrombocytopenia in one patient. Alkaline phosphatase increased (17%, p<0.01) only at two hours, and erythrocyte count (6%, p<0.05) at 24 hours after injection. Our initial results indicate diagnostic advantages of Intraiodol without serious adverse reactions. Further clinical studies are required to confirm these findings.


1972 ◽  
Vol 1 ◽  
pp. 27-38
Author(s):  
J. Hers

In South Africa the modern outlook towards time may be said to have started in 1948. Both the two major observatories, The Royal Observatory in Cape Town and the Union Observatory (now known as the Republic Observatory) in Johannesburg had, of course, been involved in the astronomical determination of time almost from their inception, and the Johannesburg Observatory has been responsible for the official time of South Africa since 1908. However the pendulum clocks then in use could not be relied on to provide an accuracy better than about 1/10 second, which was of the same order as that of the astronomical observations. It is doubtful if much use was made of even this limited accuracy outside the two observatories, and although there may – occasionally have been a demand for more accurate time, it was certainly not voiced.


Author(s):  
J. Frank ◽  
P.-Y. Sizaret ◽  
A. Verschoor ◽  
J. Lamy

The accuracy with which the attachment site of immunolabels bound to macromolecules may be localized in electron microscopic images can be considerably improved by using single particle averaging. The example studied in this work showed that the accuracy may be better than the resolution limit imposed by negative staining (∽2nm).The structure used for this demonstration was a halfmolecule of Limulus polyphemus (LP) hemocyanin, consisting of 24 subunits grouped into four hexamers. The top view of this structure was previously studied by image averaging and correspondence analysis. It was found to vary according to the flip or flop position of the molecule, and to the stain imbalance between diagonally opposed hexamers (“rocking effect”). These findings have recently been incorporated into a model of the full 8 × 6 molecule.LP hemocyanin contains eight different polypeptides, and antibodies specific for one, LP II, were used. Uranyl acetate was used as stain. A total of 58 molecule images (29 unlabelled, 29 labelled with antl-LPII Fab) showing the top view were digitized in the microdensitometer with a sampling distance of 50μ corresponding to 6.25nm.


Author(s):  
A. V. Crewe

We have become accustomed to differentiating between the scanning microscope and the conventional transmission microscope according to the resolving power which the two instruments offer. The conventional microscope is capable of a point resolution of a few angstroms and line resolutions of periodic objects of about 1Å. On the other hand, the scanning microscope, in its normal form, is not ordinarily capable of a point resolution better than 100Å. Upon examining reasons for the 100Å limitation, it becomes clear that this is based more on tradition than reason, and in particular, it is a condition imposed upon the microscope by adherence to thermal sources of electrons.


Author(s):  
Li Li-Sheng ◽  
L.F. Allard ◽  
W.C. Bigelow

The aromatic polyamides form a class of fibers having mechanical properties which are much better than those of aliphatic polyamides. Currently, the accepted morphology of these fibers as proposed by M.G. Dobb, et al. is a radial arrangement of pleated sheets, with the plane of the pleats parallel to the axis of the fiber. We have recently obtained evidence which supports a different morphology of this type of fiber, using ultramicrotomy and ion-thinning techniques to prepare specimens for transmission and scanning electron microscopy.


Author(s):  
P.R. Swann ◽  
A.E. Lloyd

Figure 1 shows the design of a specimen stage used for the in situ observation of phase transformations in the temperature range between ambient and −160°C. The design has the following features a high degree of specimen stability during tilting linear tilt actuation about two orthogonal axes for accurate control of tilt angle read-out high angle tilt range for stereo work and habit plane determination simple, robust construction temperature control of better than ±0.5°C minimum thermal drift and transmission of vibration from the cooling system.


Author(s):  
K.C. Newton

Thermal effects in lens regulator systems have become a major problem with the extension of electron microscope resolution capabilities below 5 Angstrom units. Larger columns with immersion lenses and increased accelerating potentials have made solutions more difficult by increasing the power being handled. Environmental control, component choice, and wiring design provide answers, however. Figure 1 indicates with broken lines where thermal problems develop in regulator systemsExtensive environmental control is required in the sampling and reference networks. In each case, stability better than I ppm/min. is required. Components with thermal coefficients satisfactory for these applications without environmental control are either not available or priced prohibitively.


Sign in / Sign up

Export Citation Format

Share Document