New morphological factor for predicting late proximal type I endoleak after endovascular aneurysm repair

Author(s):  
Hiroshi Banno ◽  
Masayuki Sugimoto ◽  
Tomohiro Sato ◽  
Shuta Ikeda ◽  
Yohei Kawai ◽  
...  
2018 ◽  
Vol 11 (1) ◽  
pp. e5-e6 ◽  
Author(s):  
Omar A. Ayah ◽  
Jordan Klein ◽  
Muhammad Raza ◽  
Daniel J. McCormick

2018 ◽  
Vol 25 (3) ◽  
pp. 379-386 ◽  
Author(s):  
Dainis Krievins ◽  
Albrecht Krämer ◽  
Janis Savlovskis ◽  
Georgij Oszkinis ◽  
E. Sebastian Debus ◽  
...  

Purpose: To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double “D-shaped” stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. Methods: From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, and blood loss ≥1000 mL), and clinical success (freedom from procedure-related death, type I/III endoleak, migration, thrombosis, and reintervention). Results: Endografts were successfully implanted in 89 (99%) patients; the single failure was due to delivery system malfunction before insertion in the early-generation device. One (1%) patient died and 4 patients underwent reinterventions (1 type I endoleak, 2 iliac limb stenoses, and 1 endograft occlusion) within the first 30 days. During a median follow-up of 12.5 months (range 11.5–50.9), there were no aneurysm ruptures, surgical conversions, or AAA-related deaths. The cumulative MAE rates were 3% (3/89) at 6 months and 7% (6/89) at 1 year. Two patients underwent coil embolization of type II endoleaks at 6.5 months and 2.2 years, respectively. Clinical success was 94% (84/89) at 30 days, 98% (85/87) at 6 months, and 99% (82/83) at 1 year. Conclusion: Early results suggest that properly selected AAA patients can be safely treated using the Altura Endograft System with favorable midterm outcome. Thus, further clinical investigation is warranted to evaluate the role of this device in the treatment of AAA.


2019 ◽  
Vol 53 (6) ◽  
pp. 515-519
Author(s):  
Toshiya Nishibe ◽  
Toru Iwahashi ◽  
Kentaro Kamiya ◽  
Masaki Kano ◽  
Keita Maruno ◽  
...  

We present 3 cases of type IIIb endoleak after endovascular aneurysm repair (EVAR) using the Zenith stent graft system. Type III endoleak, like type I endoleak, is a high-pressure, high-risk leak that increases sac pressure up to or even above arterial pressure, and is associated with an increased frequency of open conversions or risk of aneurysm rupture. Type IIIb endoleak is rare but there is much concern that the incidence of type IIIb endoleak is likely to increase hereafter; the mechanism of type IIIb endoleak is deterioration of graft fabric in conjunction with stent sutures. Type IIIb endoleak is difficult to diagnose before rupture. The possibility of type IIIb endoleak should be highly suspected when the continued growth of an excluded aneurysm sac without direct radiologic evidence is observed during follow-up. Type IIIb endoleak can be repaired by relining of the stent graft with additional stent grafts.


Vascular ◽  
2019 ◽  
Vol 27 (5) ◽  
pp. 495-499 ◽  
Author(s):  
Reza Masoomi ◽  
Emily Lancaster ◽  
Alexander Robinson ◽  
Ethan Hacker ◽  
Zvonimir Krajcer ◽  
...  

Objectives A hostile proximal neck anatomy is the most common cause of abdominal aorta endovascular aneurysm repair failure leading to a higher risk of device migration, proximal type I endoleak, and subsequent open surgical repair. Endostapling is a technique to attain better fixation of the endograft to the aortic wall, and the only available device in the USA is Aptus Heli-FX EndoAnchor system (Medtronic Vascular, Santa Rosa, CA, USA). Preliminary data have shown efficacy and safety of its use, and the aim of this study is to assess device-related adverse events in real-world clinical use. Methods We quarried data from the publicly available Manufacturer and User Facility Device Experience database to identify Aptus Heli-FX EndoAnchor system-related adverse reports in endovascular aneurysm repair since FDA approval till August 31, 2017. An estimate of total devices implanted in the United States was quoted around 7,000 (Medtronic marketing internal data). Results Our query identified 229 separate reports, of which there were 85 adverse events (1.2% of the estimated EndoAnchor systems used). The most common adverse events were device dislodgement/fracture (65) and applicator malfunction (20). Conclusion In early post-FDA approval use in a real-world setting, the EndoAnchor system is associated with a low rate of adverse events. Device dislodgement and embolization remain the most common adverse events. With increasing use of these devices in more difficult anatomy, careful patient selection and careful attention to technique may help to reduce these events even further.


Vascular ◽  
2016 ◽  
Vol 25 (1) ◽  
pp. 92-100 ◽  
Author(s):  
Yang Yaoguo ◽  
Chen Zhong ◽  
Kou Lei ◽  
Xiao Yaowen

Objective We reviewed data pertaining to fenestrated endograft technique and chimney stent repair of complex aortic aneurysm for comparative analysis of the outcomes. Methods A comprehensive search of relevant databases was conducted to identify articles in English, related to the treatment of complex aortic aneurysm with fenestrated endovascular aneurysm repair and chimney stent repair, published until January 2015. Results A total of 42 relevant studies and 2264 patients with aortic aneurysm undergoing fenestrated endovascular aneurysm repair and chimney stent repair were included in our review. A total of 4413 vessels were involved in these processes. The cumulative 30-day mortality was 2.4% and 3.2% ( p = 0.459). The follow-up aneurysm-related mortality was 1.4% and 3.2% ( p = 0.018), and target organ dysfunction was 5.0% and 4.0% in fenestrated endovascular aneurysm repair and chimney stent repair, respectively ( p = 0.27). A total of 156 vessels showed restenosis or occlusion after primary intervention (3.6% and 3.4% in fenestrated endovascular aneurysm repair and chimney stent repair, respectively, p = 0.792). The cumulative type I endoleak was 2.0% (38/1884) after fenestrated endovascular aneurysm repair compared with 3.4% (13/380) after chimney stent repair ( p = 0.092), and the type II endoleak was 5.4% (102/1884) and 5.3% (20/380), respectively ( p = 0.905). Approximately, 1.1% and 1.6% increase in aneurysm was observed following fenestrated endovascular aneurysm repair and chimney stent repair, respectively ( p = 0.437). The re-intervention frequency was 205 and 19 cases after fenestrated endovascular aneurysm repair and chimney stent repair, respectively (11.7%, 5.6%, p = 0.001). Conclusions Fenestrated endovascular aneurysm repair and chimney stent repair are safe and effective in treating patients with complex aortic aneurysm. A higher aneurysm-related mortality was observed in chimney stent repair while fenestrated endovascular aneurysm repair was associated with a higher re-intervention rate.


2016 ◽  
Vol 24 (1) ◽  
pp. 59-67 ◽  
Author(s):  
George N. Kouvelos ◽  
Kyriakos Oikonomou ◽  
George A. Antoniou ◽  
Eric L. G. Verhoeven ◽  
Athanasios Katsargyris

Purpose: To provide an updated systematic literature review and summarize current evidence on proximal aortic neck dilatation (AND) after endovascular aneurysm repair (EVAR). Methods: A review of the English-language medical literature from 1991 to 2015 was conducted using MEDLINE and EMBASE to identify studies reporting AND after EVAR. Studies considered for inclusion and full-text review fulfilled the following criteria: (1) reported AND after EVAR, (2) included at least 5 patients, and (3) provided data on AND quantification. The search identified 26 articles published between 1998 and 2015 that encompassed 9721 patients (median age 71.8 years; 9439 men). Results: AND occurred in 24.6% of patients (95% CI 18.6% to 31.8%) over a period ranging from 15 months to 9 years after EVAR. No significant dilatation of the suprarenal part of the aorta was reported by most studies. The incidence of combined clinical events (endoleak type I, migration, reintervention during follow-up) was higher in the AND group (26%) when compared with 2% in the group without AND (OR 28.7, 95% CI 5.43 to 151.67, p<0.001). Conclusion: AND affects a considerable proportion of EVAR patients and was related to worse clinical outcome, as indicated by increased rates of type I endoleak, migration, and reinterventions. Future studies should focus on a better understanding of the pathophysiology, predictors, and risk factors of AND, which could identify patients who may warrant a different EVAR strategy and/or a closer post-EVAR surveillance strategy.


2019 ◽  
Vol 43 (1) ◽  
pp. 18-24
Author(s):  
Joshua D. Lee ◽  
Courtney Webb ◽  
Mark W. Fugate

Abdominal aortic disease affects more than 3 million people per year. For vascular sonographers, imaging aortic disease can become routine. Therefore, it is necessary to expand the knowledge that we have of aortic disease, diagnosis, and treatment. We present 4 cases with new or worsening conditions diagnosed by duplex ultrasound (DUS). Our first case is a 79-year-old woman returning for surveillance of an endovascular aneurysm repair (EVAR). The DUS findings reveal an increasing abdominal aortic aneurysm (AAA) sac, with evidence of flow originating from an incomplete seal at the attachment suggesting type I endoleak. Next, is a 56-year-old man returning 1 month after type A dissection repair, now presenting with unilateral claudication. The DUS findings of the left lower extremity demonstrated an early systolic deceleration waveform, suggesting more proximal disease. Upon further imaging, an abdominal aortic dissection was identified terminating into the left internal iliac artery, causing the true lumen to be compressed. The third case was a 75-year-old man returning for follow-up of an EVAR and iliac repair. The DUS findings show an increase in iliac artery sac size and anechoic area that was filled with color Doppler flow. These findings are suggestive of type I endoleak involving the distal attachment. The last case is a 56-year-old man returning for EVAR and iliac artery repair surveillance. The common iliac artery aneurysm sac had increased in diameter and length. The distal attachment of the left iliac extension cuff terminated within the aneurysm sac, causing a type I endoleak. Accurate DUS diagnosis of aortic disease is crucial for patient care. Meticulous analysis of the vessels and surrounding structures can make a difference in diagnostic outcomes. Vascular sonographers should continually review and revise vascular laboratory protocols to increase their diagnostic accuracy and improve patient care. It is important to extend the vascular laboratory protocols when complex cases arise to better demonstrate complicated diagnoses and challenging anatomy.