Biomolecular stiffness detection based on positive frequency shift of CMOS compatible gigahertz solidly mounted resonators

2017 ◽  
Vol 96 ◽  
pp. 206-212 ◽  
Author(s):  
Qingrui Yang ◽  
Shuting Pan ◽  
Yuan Zhao ◽  
Hao Zhang ◽  
Wei Pang ◽  
...  
Chemosensors ◽  
2021 ◽  
Vol 9 (1) ◽  
pp. 9
Author(s):  
Sawit Na Songkhla ◽  
Takamichi Nakamoto

In odor sensing based on Quartz Crystal Microbalances (QCMs), the sensing film is crucial for both sensor sensitivity and selectivity. The typical response of the QCM due to sorption is a negative frequency shift. However, in some cases, the sorption causes a positive frequency shift, and then, Sauerbrey’s equation and Kanazawa’s equation cannot be applied to this situation. We model the QCM response with a Mason equivalent circuit. The model approximates a single layer of a uniform viscous coating on the QCM. The simulation of the equation circuit shows the possibility of the positive frequency change when the sorption occurs, which is the situation we find in some of the odor sensing applications. We measured the QCM frequency and resistance using the Vector Network Analyzer (VNWA). The QCMs were coated with glycerol, PEG2000, and PEG20M. To simulate odor exposure, a microdispenser was used to deposit the water. A positive frequency shift was observed in the case of PEG2000, and a negative frequency change was obtained for PEG20M. These results can be explained by the Mason equivalent circuit, with the assumption that when the film is exposed to water, its thickness increases and its viscosity decreases.


Photonics ◽  
2021 ◽  
Vol 8 (10) ◽  
pp. 436
Author(s):  
Yuhe Wang ◽  
Yudong Lian ◽  
Shiwei Han ◽  
Yang Yu ◽  
Xuan Qi ◽  
...  

A scheme for controlling the frequency difference of output pulse pair with double frequency shift loops is proposed. The frequency shift system includes two loop elements of 20 and 200 MHz. The first one carries out a single selective positive frequency shift of 1–20 MHz, and the second one can satisfy a single fixed positive frequency shift of 200 MHz. The reverse cascade technology of two acousto-optic crystals is introduced to solve the limitation of the small frequency shift of crystal size. A multichannel synchronization signal completes the time domain control of each acousto-optic modulator. Finally, the frequency shift difference of the output pulse pair ranges of 0–2 GHz, and the frequency shift accuracy is 5 MHz.


1992 ◽  
Vol 2 (7) ◽  
pp. 1367-1372
Author(s):  
R. C. Bobulescu ◽  
M. A. Brǎtescu ◽  
C. Stǎnciulescu ◽  
G. Musa

2012 ◽  
Vol 6 (1) ◽  
pp. 14-17
Author(s):  
Jabin Akhter ◽  
Shaheda Anwar ◽  
Sharmeen Ahmed

Urinary tract infection caused by Enterococci has become frequent occurrences in health care settings. Currently they emerged with increasing resistance to multiple antibiotics.  Haemolysin, gelatinase and biofilm production are some markers that have been proposed as possible Enterococcal virulence factors. In view of the increasing importance of Enterococcal infection, the present study was designed to isolate and identify the Enterococci to the species level from urine of urinary tract infection patients and to investigate their possible virulence factors. Biofilm was detected on polystyrene microtitre plate to see the adherence of microorganism. Haemolysin production and gelatin hydrolysis detected by standard microbiological method. Fifty nine enterococcal isolates were speciated by conventional microbiological method and examined for their ability to form biofilm by microtitre plate assay. In this study, biofilm formations by Enterococci were found in 83.33% isolates from catheterized and 56.09% from non-catheterized patients. Aong them, E.faecalis & 50% E.faecium produced biofilm. About 43.63% E.faecalis & 10% E.faecium produced haemolysin and only one isolate were found to be gelatinase positive. Frequency of virulence factors (VFs) in combination was observed in this study. Two VFs (haemolysin and biofilm) were observed in 27.11% in combination and 3 VFs ( haemolysinm biofilm and gelatinase) were present in 1.69% isolates. These results suggest that although there may not be an absolute role for individual virulence determinants in infectivity, combinations of factors may play a role in allowing a biofilm infection to be more resistant to therapy.DOI: http://dx.doi.org/10.3329/bjmm.v6i1.19361 Bangladesh J Med Microbiol 2012; 06(01): 14-17


2010 ◽  
Vol 130 (5) ◽  
pp. 170-175
Author(s):  
Tsukasa Fujimori ◽  
Hideaki Takano ◽  
Yuko Hanaoka ◽  
Yasushi Goto

Author(s):  
Ruslan V. Aginey ◽  
◽  
Rustem R. Islamov ◽  
Alexander A. Godunov ◽  
◽  
...  

Sign in / Sign up

Export Citation Format

Share Document