scholarly journals Optimizing the lateral beamforming step for filtered-delay multiply and sum beamforming to improve active contour segmentation using ultrafast ultrasound imaging

2022 ◽  
Vol 71 ◽  
pp. 103267
Author(s):  
Asraf Mohamed Moubark ◽  
Zainab Alomari ◽  
Mohd Hairi Mohd Zaman ◽  
Mohd Asyraf Zulkifley ◽  
Sawal Hamid Md Ali ◽  
...  
2012 ◽  
Vol 10 (1) ◽  
pp. 25-29 ◽  
Author(s):  
Tanja Sommer ◽  
Martin Meier ◽  
Frank Bruns ◽  
Reinhard Pabst ◽  
Gerhard Breves ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
L. Meziou ◽  
A. Histace ◽  
F. Precioso ◽  
O. Romain ◽  
X. Dray ◽  
...  

Visualization of the entire length of the gastrointestinal tract through natural orifices is a challenge for endoscopists. Videoendoscopy is currently the “gold standard” technique for diagnosis of different pathologies of the intestinal tract. Wireless capsule endoscopy (WCE) has been developed in the 1990s as an alternative to videoendoscopy to allow direct examination of the gastrointestinal tract without any need for sedation. Nevertheless, the systematic postexamination by the specialist of the 50,000 (for the small bowel) to 150,000 images (for the colon) of a complete acquisition using WCE remains time-consuming and challenging due to the poor quality of WCE images. In this paper, a semiautomatic segmentation for analysis of WCE images is proposed. Based on active contour segmentation, the proposed method introduces alpha-divergences, a flexible statistical similarity measure that gives a real flexibility to different types of gastrointestinal pathologies. Results of segmentation using the proposed approach are shown on different types of real-case examinations, from (multi)polyp(s) segmentation, to radiation enteritis delineation.


2019 ◽  
Vol 4 (2) ◽  
pp. 8-10
Author(s):  
Sintha Syaputri ◽  
Zulkarnain

Research on medical image objects in the form of lung images of thoracic X-Rayis increasingly being developed because the information contained in medical images is used to analyze and determine the shape of the lungs. The process of normalization and image improvement is needed and continued with the segmentation process using the right method. The active snake contour method is used because it is resistant to the noise around the object. The research has been usedthe Matlab software GUI program version R2015a. The image through the initial preprocessing stage is converted into a grayscale image. The segmentation process used after the initialization process in the form of a small circle curve placed of the object to be segmented and the determination position of the active contour or detemination of the active parameters of the contour. Determination of the value active contour parameters greatly influences the results of segmentation and influences the direction of active contour movement. If the active coordinate position of the contour is outside the area to be segmented it will cause active contours to move away from the object. Validation the level of accuracy of segmentation results is done by comparing the results of the snake active contour segmentation to the results of manual segmentationused MSE method


Sign in / Sign up

Export Citation Format

Share Document