Investigation of indoor environment quality and factors affecting human comfort: A critical review

2021 ◽  
pp. 108146
Author(s):  
Ghogare Abhijeet Ganesh ◽  
Shobha Lata Sinha ◽  
Tikendra Nath Verma ◽  
Satish Kumar Dewangan

The present study emphases the numerical investigation of the change in the overall indoor environment of a mechanically heated room, due to alteration in direction of the cold air stream at the inlet. This study is important to find the correlation between the configuration of altered geometry on the indoor environment quality and human comfort. Different case studies have been studied by altering the direction of the flow of the unidirectional velocity vector (U) by turning clockwise around the Z-axis and keeping other geometry parameters unaltered. Numerically simulated observations have been analyzed to study the effect of changed airflow direction at the inlet on indoor environmental quality Slight variations in the indoor environment were observed due to changed inlet angle set from 0°-60°, but for the largest angle setting of (80°), considerable changes were observed ins temperature and flow patterns. When the inlet vent angle increased from 0°-80°, the airflow and thermal pattern in room changes. More swirls and circulation observed in the case of higher inlet angles. PPD values for subsequent cases were found under control for all the set of inlet angles. The lowest PPD and PMV values observed for an 80° inlet angle setting. The outcomes of the research would be valuable for the design and optimization of local buildings and more energy can be hoarded by proper installations of equipment and inlet vent location


2018 ◽  
Vol 10 (1) ◽  
pp. 19-26
Author(s):  
Jason Obadiah

Recently, many facilities have completed new laboratories that may be used to assess various measures of Indoor Environment Quality (IEQ) in office spaces. Also recently, a new standard, ISO 3382-3, was released for assessing the effects of speech on IEQ in open plan offices. The aim of this report is to assess one room of the IEQ lab using the ISO 3382-3 standard. It is expected that the data gained will be of help to researchers using the facility in the future. Keywords: ISO 3382-3, Indoor Environment Quality, Acoustics


Author(s):  
Sultan Hassan Alamri ◽  
Nadeem Ali ◽  
Hussain Mohammed Salem Ali Albar ◽  
Muhammad Imtiaz Rashid ◽  
Nisreen Rajeh ◽  
...  

To control the spread of coronavirus disease (COVID-19), Saudi Arabia’s government imposed a strict lockdown during March–July 2020. As a result, the public was confined to indoors, and most of their daily activities were happening in their indoor places, which might have resulted in lower indoor environment quality. Polycyclic aromatic hydrocarbons (PAHs) were analyzed in household dust (n = 40) collected from different residential districts of Jeddah, Saudi Arabia, during the lockdown period. PAHs’ levels were two folds higher than the previously reported PAHs in indoor dust from this region. We detected low molecular weight (LMW) with two to four aromatic ring PAHs in all the samples with a significant contribution from Phenanthrene (Phe), present at an average concentration of 1590 ng/g of dust. Although high molecular weight (HMW) (5–6 aromatic ring) PAHs were detected at lower concentrations than LMW PAHs, however, they contributed >90% in the carcinogenic index of PAHs. The estimated daily intake (EDI) of specific PAHs was above the reference dose (RfD) for young children in high-end exposure and the calculated Incremental Lifetime Cancer Risk (ILCR) was >1.00 × 10−4 for both Saudi adults and young children. The study highlighted that indoor pollution has increased significantly during lockdown due to the increased indoor activities and inversely affect human health. This study also warrants to conduct more studies involving different chemicals to understand the indoor environment quality during strict lockdown conditions.


2010 ◽  
Vol 5 (1) ◽  
pp. 132-154 ◽  
Author(s):  
Tracie J Reed ◽  
Peggi L Clouston ◽  
Simi Hoque ◽  
Paul R Fisette

This study examines the differences between two environmental assessment methods for the K-12 education sector: the United States Green Building Council's (USGBC) LEED Schools Version 3.0 and the British Research Establishment's (BRE) BREEAM Education issue 2.0. Credit requirements are compared side-by-side and against recommendations from researchers in areas such as acoustics, lighting and indoor environment quality. Strengths in the two schemes and areas for improvement are highlighted, with acknowledgement that each scheme offers components and techniques from which the other could benefit.


Author(s):  
F. O. Ezeokoli ◽  
C. A. Omenyi ◽  
C. B. N. Bert- Okonkwo ◽  
N. B. Iheama

This study aimed at evaluating the indoor environment conditions of the private hostels in Ifite Awka Anambra state with a view to establishing its quality and impacts on students dwelling on these hostels in the study area. Being a survey research, the study was affected by the use of questionnaire, literature searches and direct observations. Accordingly, a total of 311 questionnaires were administered while 258 questionnaires which represent 83% were returned and found useful. The study found that IEQ parameters of hostels in study area are: Indoor air quality was poor due to inadequate ventilation of rooms; thermal comfort of rooms was found to be warm; indoor light quality was found good and the acoustics comfort and noise slightly good and to some extent poor. Therefore, the study recommended that during the design and construction of buildings, IEQ parameters should be considered, so as to obtain a quality indoor environment.