Feasibility study of a reference material for water chemistry: Long term stability of triazine and phenylurea residues stored in vials or on polymeric sorbents

2006 ◽  
Vol 1123 (1) ◽  
pp. 31-37 ◽  
Author(s):  
Jérôme Deplagne ◽  
Jérôme Vial ◽  
Valérie Pichon ◽  
Béatrice Lalere ◽  
Gilles Hervouet ◽  
...  
Molecules ◽  
2021 ◽  
Vol 26 (14) ◽  
pp. 4370
Author(s):  
Liping Fang ◽  
Linyan Huang ◽  
Gang Yang ◽  
Yang Jiang ◽  
Haiping Liu ◽  
...  

Water matrix certified reference material (MCRM) of volatile organic compounds (VOCs) is used to provide quality assurance and quality control (QA/QC) during the analysis of VOCs in water. In this research, a water MCRM of 28 VOCs was developed using a “reconstitution” approach by adding VOCs spiking, methanol solution into pure water immediately prior to analysis. The VOCs spiking solution was prepared gravimetrically by dividing 28 VOCs into seven groups, then based on ISO Guide 35, using gas chromatography-mass spectrometry (GC-MS) to investigate the homogeneity and long-term stability. The studies of homogeneity and long-term stability indicated that the batch of VOCs spiking solution was homogeneous and stable at room temperature for at least 15 months. Moreover, the water MCRM of 28 VOCs was certified by a network of nine competent laboratories, and the certified values and expanded uncertainties of 28 VOCs ranged from 6.2 to 17 μg/L and 0.5 to 5.3 μg/L, respectively.


1995 ◽  
Vol 74 (06) ◽  
pp. 1465-1467 ◽  
Author(s):  
A M H P van den Besselaar

SummaryIn a collaborative study by eleven laboratories performed within the framework of the European Community Bureau of Reference (BCR), a third reference material for thromboplastin, rabbit, plain, has been calibrated against RBT/90, the current WHO international reference preparation for thromboplastin, rabbit, plain. This third reference material (coded CRM 149S) has a mean International Sensitivity Index (ISI)of 1.257 with a standard error of the mean of 0.013.The previous BCR reference material for thromboplastin, rabbit, plain (coded CRM 149R) and the reference material for thromboplastin, bovine, combined (coded OBT/79) were also included in the trial for assessment of the long-term stability of the ISI values. The relationship between ISI values determined in the present study was nearly identical to that of the historical values. These results offer reassurance with regard to the long-term stability of these reference materials.


2020 ◽  
Vol 393 ◽  
pp. 124692 ◽  
Author(s):  
Jun Duan ◽  
Haodong Ji ◽  
Xiao Zhao ◽  
Shuting Tian ◽  
Xiaona Liu ◽  
...  

2010 ◽  
Vol 15 (4) ◽  
pp. 233-238
Author(s):  
Edson Gonçalves Moreira ◽  
M. B. A. Vasconcellos ◽  
M. G. M. Catharino ◽  
V. A. Maihara ◽  
M. Saiki

Sign in / Sign up

Export Citation Format

Share Document