Durability of concrete under sulfate attack exposed to freeze–thaw cycles

2015 ◽  
Vol 112 ◽  
pp. 112-117 ◽  
Author(s):  
Lei Jiang ◽  
Ditao Niu ◽  
Lidong Yuan ◽  
Qiannan Fei
Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4421
Author(s):  
Dušan Zoran Grdić ◽  
Gordana Aleksandar Topličić-Ćurčić ◽  
Zoran Jure Grdić ◽  
Nenad Srboljub Ristić

This paper presents the testing of the durability of concrete where a part of cement was replaced with ground panel cathode ray tube glass (CRT) finer than 63 µm. The percentage of cement replaced with glass is 5%, 10%, 15%, 20%, and 35%, by mass. The highest percent share of mineral admixtures in CEM II (Portland-composiste cement) cement was chosen as the top limit of replacement of cement with glass. In terms of the concrete durability, the following tests are performed: freeze-thaw resistance, freeze-thaw resistance with de-icing salts-scaling, resistance to wear according to the Böhme test, sulfate attack resistance, and resistance to penetration of water under pressure. A compressive strength test is performed, and shrinkage of concrete is monitored. In order to determine the microstructure of concrete, SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-ray Spectroscopy) analyses were performed. The obtained research results indicate that the replacement of a part of cement with finely ground CRT glass up to 15% by mass has a positive effect on the compressive strength of concrete in terms of its increase without compromising the durability of concrete. The results obtained by experimental testing unequivocally show that concrete mixtures made with partial replacement (up to 15%) of cement with finely ground CRT glass have the same freeze-thaw resistance, resistance to freeze/thaw with de-icing salt, resistance to wear by abrasion, and resistance to sulfate attack as the reference concrete. In terms of environmental protection, the use of CRT glass as a component for making concrete is also very significant.


2019 ◽  
Author(s):  
Zhengyao Qu ◽  
Shuaiqi Guo ◽  
Christian C. M. Sproncken ◽  
Romà Surís-Valls ◽  
qingliang yu ◽  
...  

Frost weathering of porous materials caused by seasonal temperature changes is a major source of damage to the world’s infrastructure and cultural heritage. Here we investigate poly(vinyl alcohol) (PVA) addition as a means to enhance the freeze-thaw durability of concrete without compromising its structural or mechanical integrity. We evaluate the ice recrystallization inhibition activity of PVA in a cementitious environment and the impact of PVA on key structural and mechanical properties, such as cement hydration (products), microstructure, strength, as well as freeze‑thaw resistance. We find that a low amount of PVA significantly reduces the surface scaling of concrete and displays excellent ice recrystallization inhibition in the saturated Ca(OH)<sub>2 </sub>solution which has a similar pH value as cement pore solution, while it does not affect cement hydration, microstructure, nor its mechanical properties. These findings contribute to new insights on freeze-thaw damage mechanism and more importantly we disclose a new direction for the design of concrete with excellent freeze‑thaw resistance.


2022 ◽  
Vol 321 ◽  
pp. 126371
Author(s):  
Ruijun Wang ◽  
Zhiyao Hu ◽  
Yang Li ◽  
Kai Wang ◽  
Hao Zhang

2013 ◽  
Vol 20 (1) ◽  
pp. 57-65 ◽  
Author(s):  
Peng Zhang ◽  
Qing-fu Li

AbstractIn this paper, the effect of silica fume on the workability and durability of concrete composites containing fly ash, including water impermeability, dry shrinkage property, carbonation resistance and freeze-thaw resistance, are presented. Four different silica fume contents (3%, 6%, 9% and 12%) were used. The results indicate that the addition of silica fume has greatly improved the durability of water impermeability, the carbonation resistance and the freeze-thaw resistance of the concrete composites containing fly ash. With the increase in silica fume content, the length of water permeability and the carbonation depth of the specimens decrease gradually, and the relative dynamic elastic modulus of the specimens has a tendency to increase. However, the addition of silica fume has a little adverse effect on the workability and dry shrinkage property of concrete composites containing fly ash. With the increase in silica fume content, both the slump and the slump flow decrease gradually, and the dry shrinkage strain increases gradually.