A nonlinear analytical model of composite plate structure with an MRE function layer considering internal magnetic and temperature fields

2020 ◽  
Vol 200 ◽  
pp. 108445 ◽  
Author(s):  
Hui Li ◽  
Wenyu Wang ◽  
Xintong Wang ◽  
Qingkai Han ◽  
Jinguo Liu ◽  
...  
2020 ◽  
Vol 2020 ◽  
pp. 1-16
Author(s):  
Xiangqian Liu ◽  
Yan Yu ◽  
Shengli Yang ◽  
Huijie Liu

In the conventional analytical model used for heat generation in friction stir welding (FSW), the heat generated at the pin/workpiece interface is assumed to distribute uniformly in the pin volume, and the heat flux is applied as volume heat. Besides, the tilt angle of the tool is assumed to be zero for simplicity. These assumptions bring about simulating deviation to some extent. To better understand the physical nature of heat generation, a modified analytical model, in which the nonuniform volumetric heat flux and the tilt angle of the tool were considered, was developed. Two analytical models are then implemented in the FEM software to analyze the temperature fields in the plunge and traverse stage during FSW of AA6005A-T6 aluminum hollow extrusions. The temperature distributions including the maximum temperature and heating rate between the two models are different. The thermal cycles in different zones further revealed that the peak temperature and temperature gradient are very different in the high-temperature region. Comparison shows that the modified analytical model is accurate enough for predicting the thermal cycles and peak temperatures, and the corresponding simulating precision is higher than that of the conventional analytical model.


Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 1084
Author(s):  
Toky Rabenimanana ◽  
Vincent Walter ◽  
Najib Kacem ◽  
Patrice Le Moal ◽  
Joseph Lardiès

This paper presents a nonlinear analytical model of MEMS mass sensor, which is composed of two cantilevers of 98 µm and 100 µm length, 20 µm width and 1.3 µm thick. They are connected by a coupling beam and only the shortest cantilever is actuated by a combined AC-DC voltage. The DC voltage is used to equilibrate the system and the phenomenon of mode localization is investigated when a mass perturbation is applied. The sensor is modeled as a continuous system with beam theory and non-ideal boundary conditions are considered by using flexible supports. With a low AC voltage of 10 mV, a DC voltage of 5.85 V can counterbalance the length difference. This DC voltage decreases at 5.60 V when we increase the AC voltage, due to the effect of electrostatic nonlinearities. For a relative added mass of 0.1%, the amplitude change in the two cantilevers is more important when the coupling is weaker.


Sign in / Sign up

Export Citation Format

Share Document