Concrete Quality Designation based on Ultrasonic Pulse Velocity

2016 ◽  
Vol 125 ◽  
pp. 1022-1027 ◽  
Author(s):  
François Saint-Pierre ◽  
Alain Philibert ◽  
Bernard Giroux ◽  
Patrice Rivard
2019 ◽  
pp. 22-40
Author(s):  
Khalid Abdel Naser Abdel Rahim

This manuscript investigate the quality of concrete using non-destructive in-situ testing.The in-situ testing is a process by which different test are carried out such as rebound hammer, ultrasonic pulse veloc-ity, initial surface absorption test and fig air, to determine thein-situ strength, durability and deterioration, air permeability, concrete quality control andperformance. Additionally, the quality of concrete was researched using test methods with experimental results. Moreover, this research has found that (1) the increase in w/c ra-tioleads to a decrease in compressive strength and ultrasonic pulse velocity. Thus, lower w/cratio gives a bet-ter concrete strength in terms of quality, (2) the quicker the ultrasonic pulse travels through concrete indicates that the concrete is denser, therefore, better quality, (3) the lower initial surface absorption value indicates a better concrete with respect to porosity and (4) the w/c ratio plays an important role in the strength and per-meability of concrete.


Author(s):  
Van Viet Thien An

In the present study, the uniformity and potential internal defects of concrete elements in situ were assessed by using Ultrasonic Pulse Velocity (UPV) testing method according to TCVN 9357:2012. Thirteen cross beams with dimension of 4.8 x 1.5 x 1.5 m3 were selected to measure the pulse velocity. Three cross beams were used to check potential internal defects in concrete and 10 cross beams were used to assess the uniformity of concrete in the elements. The results showed that there is no potential internal defect with size over 100 mm in three tested beams and concrete quality of all tested beams is good with the coefficient of variation (CV) of ultrasonic pulse velocity results of all tested points is lower than 2%. Keywords: concrete; homogeneity; internal defects; ultrasonic pulse velocity.


2019 ◽  
Vol 13 (1) ◽  
pp. 201-209
Author(s):  
Muhammad I. Omer ◽  
Dilshad K. Jaf

Background: In recent years, numerous reinforced concrete buildings have been constructed in Iraq and some developing countries. Fire accidents occur in wooden formwork especially during the summer season due to problems associated with the construction procedure and on-site management. And fires can erupt during the construction stage of buildings. Introduction: Generally, if fire accidents occur in a wooden formwork, in these situations the concrete in the field is at an early age (i.e., “young”). The internal structure and chemical composition of early-age concrete are different from that of the carrier due to incomplete hydration at an early age. This study aimed to evaluate the strength of reinforced concrete frames at early ages when exposed to natural fire. The evaluation of existing buildings is an important issue that involves researchers and engineers in many countries. Methods: The experimental program consisted of constructing three full-scale reinforced concrete frames that are then exposed to natural fire. When the concrete age reaches three and five days by firing its formwork, the concrete quality of the structure was evaluated via ultrasonic pulse velocity as a nondestructive measurement. Core test was used as a destructive technique to implement a relationship between compressive strength and nondestructive measurements Results: The results showed that the frame exposed to natural fire early was generally more affected than the other frame, and its compressive strength was reduced close to 33%. The results also showed that the ultrasonic pulse velocity test for the structural elements was smaller than those of the core test Conclusion: It can be concluded that the current assessment methodology must be evaluated to provide practical suggestions that can enhance the reliability of assessing the in situ strength of existing concrete structures by nondestructive tests and cores.


2018 ◽  
Vol 196 ◽  
pp. 02045
Author(s):  
Andrzej Moczko ◽  
Marta Moczko

The paper presents overview of European standard procedures related to determining concrete quality basing on the in-situ testing. Among other things following testing methods have been discussed: testing cored specimens, rebound measurements, “pull-out” method, “pull-off” method, ultrasonic pulse velocity measurements. Testing conditions, guidelines for calibration and crucial requirement for proper interpretation of the data obtained by means of rebound and ultrasonic measurements were shown. Independently “pull-out” and “pull-off” NDT methods have been introduced. Finally, the European procedures of assessment of in-situ concrete compressive strength in structures have been also presented.


2013 ◽  
Vol 12 (3) ◽  
Author(s):  
Sudarmadi Sudarmadi

In this paper a case study about concrete strength assessment of bridge structure experiencing fire is discussed. Assessment methods include activities of visual inspection, concrete testing by Hammer Test, Ultrasonic Pulse Velocity Test, and Core Test. Then, test results are compared with the requirement of RSNI T-12-2004. Test results show that surface concrete at the location of fire deteriorates so that its quality is decreased into the category of Very Poor with ultrasonic pulse velocity ranges between 1,14 – 1,74 km/s. From test results also it can be known that concrete compressive strength of inner part of bridge pier ranges about 267 – 274 kg/cm2 and concrete compressive strength of beam and plate experiencing fire directly is about 173 kg/cm2 and 159 kg/cm2. It can be concluded that surface concrete strength at the location of fire does not meet the requirement of RSNI T-12-2004. So, repair on surface concrete of pier, beam, and plate at the location of fire is required.


Sign in / Sign up

Export Citation Format

Share Document