Steady-state and dynamic validation of a small-scale waste heat recovery system using the ThermoCycle Modelica library

Energy ◽  
2016 ◽  
Vol 115 ◽  
pp. 684-696 ◽  
Author(s):  
Adriano Desideri ◽  
Andres Hernandez ◽  
Sergei Gusev ◽  
Martijn van den Broek ◽  
Vincent Lemort ◽  
...  
Energy ◽  
2020 ◽  
Vol 205 ◽  
pp. 118059 ◽  
Author(s):  
Ł. Witanowski ◽  
P. Klonowicz ◽  
P. Lampart ◽  
T. Suchocki ◽  
Ł. Jędrzejewski ◽  
...  

2020 ◽  
Vol 6 (4) ◽  
pp. 232-242
Author(s):  
Y. Zhou ◽  
Z. Liu ◽  
A. Golyanin

The heat pipe type waste heat recovery system can effectively reduce energy consumption when the ship is sailing in a polar region, so it has great engineering application value. In order to improve the design of the heat pipe waste heat recovery system and ensure that the design parameters meet the design requirements, this project has carried out a three-dimensional simulation analysis of the internal flow field of the heat pipe waste heat recovery system. Through reasonable model processing, application of boundary conditions, and the assignment of physical attributes the flow field characteristics of the key positions of the heat pipe type waste heat recovery system were obtained scientifically and effectively. The model was simulated and calculated, and the flue gas temperature distribution in the evaporator heat exchange tube, the overall temperature distribution of the waste heat recovery system, and the temperature change curve from the cold water entering the condenser to the steady state were obtained. The change curve of the thermal efficiency of the system during the temperature of the flue gas from the evaporator to the steady state.


2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Gunabal S

Waste heat recovery systems are used to recover the waste heat in all possible ways. It saves the energy and reduces the man power and materials. Heat pipes have the ability to improve the effectiveness of waste heat recovery system. The present investigation focuses to recover the heat from Heating, Ventilation, and Air Condition system (HVAC) with two different working fluids refrigerant(R410a) and nano refrigerant (R410a+Al2O3). Design of experiment was employed, to fix the number of trials. Fresh air temperature, flow rate of air, filling ratio and volume of nano particles are considered as factors. The effectiveness is considered as response. The results were analyzed using Response Surface Methodology


2021 ◽  
Vol 234 ◽  
pp. 113947
Author(s):  
Alexandre Persuhn Morawski ◽  
Leonardo Rodrigues de Araújo ◽  
Manuel Salazar Schiaffino ◽  
Renan Cristofori de Oliveira ◽  
André Chun ◽  
...  

2012 ◽  
Vol 204-208 ◽  
pp. 4229-4233 ◽  
Author(s):  
Fang Tian Sun ◽  
Na Wang ◽  
Yun Ze Fan ◽  
De Ying Li

Drain water at 35°C was directly discharged into sewer in most of barbershop with Electric water heater. Heat utilization efficiency is lower, and energy grade match between input and output is not appropriate in most of barbershops. Two waste heat recovery systems were presented according to the heat utilization characteristics of barbershops and principle of cascade utilization of energy. One was the waste heat recovery system by water-to-water heat exchanger (WHR-HE), and the other is the waste heat recovery system by water-to-water heat exchanger and high-temperature heat pump (WHR-CHEHP). The two heat recovery systems were analyzed by the first and second Laws of thermodynamic. The analyzed results show that the energy consumption can be reduced about 75% for HR-HE, and about 98% for WHR-CHEHP. Both WHR-HE and WHR-CHEHP are with better energy-saving effect and economic benefits.