Exergoeconomic analysis of district heating system boosted by the geothermal heat pump

Energy ◽  
2017 ◽  
Vol 119 ◽  
pp. 1159-1170 ◽  
Author(s):  
Halit Arat ◽  
Oguz Arslan
10.14311/212 ◽  
2001 ◽  
Vol 41 (2) ◽  
Author(s):  
G. Böszörményi ◽  
L. Böszörményi

The closure of a part of the municipal combined heat and power (CHP) plant of Košice city would result in the loss of 200 MW thermal output within a realtively short period of time. The long term development plan for the Košice district heating system concentrates on solving this problem. Taking into account the extremely high (90 %) dependence of Slovakia on imported energy sources and the desirability of reducing the emission of pollutantst the alternative of supplying of 100 MW thermal output from geothermal sources is attractive. However the indices of economic efficiency for this alternative are unsatisfactory. Cogeneration of electricity and heat in a CHP plant, the most efficient way of supplying heat to Košice at the present time. If as planned, geothermal heat is fed directly into the district heating network the efficiency would be greatly reduced. An excellent solution of this problem would be a new conception, preferring the utilization of geothermal heat in support of a combined electricity and heat production process. The efficiency of geothermal energy utilization could be increased through a special heat pump. This paper deals with several aspects of the design of a heat pump to be integrated into the system of the CHP plant.


2020 ◽  
Vol 5 ◽  
pp. 11
Author(s):  
Sabrin Korichi ◽  
Bachir Bouchekima ◽  
Nabiha Naili ◽  
Messaouda Azzouzi

Motivated by the rapid spread of the novel pandemic disease (COVID-19) that swept the most countries in the world, a new radiation heating system consists of wall radiator panel system connected to a reversible geothermal heat pump (GHP) coupled with horizontal ground heat exchanger (HGHX) was proposed as fast and permanent solution to the risks of the dispersion of airborne infectious diseases in air-conditioned enclosed spaces. An experimental system was installed and tested in the laboratory of thermal process of Research and Technology Center of Energy (CRTEn), Tunisia, in order to achieve the two main goals of this work: developing a new radiation heating system with quick and inexpensive implementation while ensuring high efficiency and environment-friendly performance for the entire system. The results obtained show that it is feasible to use the novel RPHs as heat rejecter of the horizontal ground source heat pump system (HGSHPs) for heating buildings with limited surface land areas epically those located in the Mediterranean regions such as Tunisia, the average performance coefficients of the geothermal heat pump COPhp and the overall system COPsys are found to be 6.3 and 3, respectively. The thermal comfort analysis indicates that there is only a small vertical temperature fluctuation in the test room that would not produce any negative effect on thermal comfort.


2011 ◽  
Vol 347-353 ◽  
pp. 1801-1805
Author(s):  
Arif Hepbasli ◽  
Mustafa Tolga Balta ◽  
Zeyad Alsuhaibani

In this study, we considered a building, which had a volume of 336 m3 and a floor area of 120 m2, with indoor and outdoor air temperatures of 20 oC and 0 oC, respectively. For heating this building, we selected two options, namely (i) a ground-source (geothermal) heat pump system (Case 1), and (ii) a solar collector heating system (Case 2). We employed both energy and exergy analysis methods to assess their performances and compare them through energy and exergy efficiencies and sustainability index. We also investigated energy and exergy flows for this building and illustrated from the primary energy transformation through the heat production system and a distribution system to a heating system, and from there, via the indoor air, across the building envelope to the surrounding air. We calculated that the total exergy efficiencies for Cases 1 and 2 were 4.7%, and 26.1% while sustainability index values for both cases were 1.049 and 1.353 at a reference (dead) state temperature of 0 oC, respectively.


Sign in / Sign up

Export Citation Format

Share Document