Effective stiffness and period-dependent seismic response modification factors for flexure-dominated fully-grouted reinforced masonry rectangular shear walls

2021 ◽  
Vol 243 ◽  
pp. 112566
Author(s):  
Layane Hamzeh ◽  
Ahmed Ashour ◽  
Nader Aly ◽  
Khaled Galal
2020 ◽  
Vol 15 (1) ◽  
pp. 37-44
Author(s):  
El Mehdi Echebba ◽  
Hasnae Boubel ◽  
Oumnia Elmrabet ◽  
Mohamed Rougui

Abstract In this paper, an evaluation was tried for the impact of structural design on structural response. Several situations are foreseen as the possibilities of changing the distribution of the structural elements (sails, columns, etc.), the width of the structure and the number of floors indicates the adapted type of bracing for a given structure by referring only to its Geometric dimensions. This was done by studying the effect of the technical design of the building on the natural frequency of the structure with the study of the influence of the distribution of the structural elements on the seismic response of the building, taking into account of the requirements of the Moroccan earthquake regulations 2000/2011 and using the ANSYS APDL and Robot Structural Analysis software.


2021 ◽  
Vol 11 (10) ◽  
pp. 4421
Author(s):  
Zhiming Zhang ◽  
Fenglai Wang

In this study, four single-story reinforced masonry shear walls (RMSWs) (two prefabricated and two cast-in-place) under reversed cyclic loading were tested to evaluate their seismic performance. The aim of the study was to evaluate the shear behavior of RMSWs with flanges at the wall ends as well as the effect of construction method. The test results showed that all specimens had a similar failure mode with diagonal cracking. However, the crack distribution was strongly influenced by the construction method. The lateral capacity of the prefabricated walls was 12% and 27% higher than that of the corresponding cast-in-place walls with respect to the rectangular and T-shaped cross sections. The prefabricated walls showed better post-cracking performance than did the cast-in-place wall. The secant stiffness of all the walls decreased rapidly to approximately 63% of the initial stiffness when the first major diagonal crack was observed. The idealized equivalent elastic-plastic system showed that the prefabricated walls had a greater displacement ductility of 3.2–4.8 than that of the cast-in-place walls with a displacement ductility value of 2.3–2.7. This proved that the vertical joints in prefabricated RMSWs enhanced the seismic performance of walls in shear capacity and ductility. In addition, the equivalent viscous damping of the specimens ranged from 0.13 to 0.26 for prefabricated and cast-in-place walls, respectively.


2019 ◽  
Vol 145 (8) ◽  
pp. 04019073 ◽  
Author(s):  
Tarek El-Hashimy ◽  
Mohamed Ezzeldin ◽  
Michael Tait ◽  
Wael El-Dakhakhni

1990 ◽  
Vol 116 (3) ◽  
pp. 619-640 ◽  
Author(s):  
P. B. Shing ◽  
M. Schuller ◽  
V. S. Hoskere

2013 ◽  
Vol 40 (9) ◽  
pp. 875-886 ◽  
Author(s):  
Jagmohan Humar ◽  
Marjan Popovski

The roof framing in single-storey buildings with large foot prints, generally used for commercial, educational, or institutional purposes, often consists of a flexible steel deck or wood panel diaphragm. Resistance to seismic lateral loads is provided by steel bracings, masonry shear walls, concrete shear walls, wood panel shear walls, or cold formed wall systems. The response of such buildings to seismic loads is strongly affected by the flexibility of the roof diaphragm. Diaphragm flexibility alters the manner in which the inertia forces, shears, and bending moments are distributed along the length of the diaphragm. In addition, it causes a significant increase in the ductility demand on the lateral load resisting system that is expected to be strained into the inelastic range under the design earthquake. Results of a study on the linear and nonlinear seismic response of buildings with flexible diaphragms are presented.


Sign in / Sign up