Out-of-Plane Performance of Reinforced Masonry Shear Walls Constructed with Boundary Elements

2019 ◽  
Vol 145 (8) ◽  
pp. 04019073 ◽  
Author(s):  
Tarek El-Hashimy ◽  
Mohamed Ezzeldin ◽  
Michael Tait ◽  
Wael El-Dakhakhni
2017 ◽  
Vol 44 (5) ◽  
pp. 367-376 ◽  
Author(s):  
Nazli Azimikor ◽  
Svetlana Brzev ◽  
Kenneth J. Elwood ◽  
Donald L. Anderson ◽  
William McEwen

Results of a study performed on the out-of-plane instability of reinforced masonry shear walls (RMSW) under seismic loading are presented. The study was conducted to gain understanding of the out-of-plane instability mechanism and the key factors influencing its development through the testing of five reinforced masonry uniaxial specimens under reversed cyclic tension and compression. The specimens represented the end zone of a RMSW. The design parameters considered in the study included longitudinal reinforcement ratio and height-to-thickness ratio for the test specimens. It was found that onset of out-of-plane instability is strongly influenced by the level of tensile strains developed in the specimens, the reinforcement ratio, and the bar size. In this case, out-of-plane instability occurred when out-of-plane displacements exceeded the critical value equal to half the wall thickness. A study on full-scale RMSW specimens subjected to reversed cyclic loading, also undertaken under this research program, is expected to verify the findings of this study and contribute towards development of design criteria for out-of-plane stability of RMSW.


2019 ◽  
Vol 13 (03n04) ◽  
pp. 1940006
Author(s):  
W. C. Xue ◽  
Y. Li ◽  
L. Cai ◽  
X. Hu

Compared with traditional precast concrete composite shear walls (PCCSWs) with two boundary elements adjacent to edges, the PCCSWs with multiple boundary elements investigated in this paper have extra boundary elements at the intersections with other shear walls. In this paper, low reversed cyclic loading tests were conducted on three full-scale shear wall specimens with multiple boundary elements under in-plane loading and two full-scale shear wall specimens under out-of-plane loading. The in-plane loaded specimens included a PCCSW with double precast layers (i.e. precast concrete double skin shear wall, PCDSSW), a PCCSW with single precast layer, and a cast-in-pace (CIP) control specimen, whereas the out-of-plane loaded specimens included a PCDSSW and a CIP control specimen. Test results revealed that all specimens failed in bending. The hysteresis loops of the precast composite specimens were stable but slightly pinching, which were similar to those of the corresponding CIP control specimen. Compared with the CIP specimens, the PCDSSWs showed similar energy dissipation. The loading capacity of the precast composite specimens was generally a little lower than that of the corresponding CIP specimen with difference not more than 15%. In the in-plane loading tests, the PCDSSW reached higher displacement ductility (2.45) than the CIP specimen (1.88), whereas the ductility of the PCCSW with single precast layer was relatively low. Regarding the specimens under out-of-plane loading, the ductility of the PCDSSW (3.83) was close to that of the CIP specimen (3.02). Moreover, the stiffness degradation of the precast composite specimens was found to be comparable to that of the control specimens. Based on the test results, a restoring force model was developed.


2019 ◽  
Vol 145 (11) ◽  
pp. 04019127 ◽  
Author(s):  
Shady Salem ◽  
Mohamed Ezzeldin ◽  
Wael El-Dakhakhni ◽  
Michael Tait

2019 ◽  
Vol 190 ◽  
pp. 389-409 ◽  
Author(s):  
B.R. Robazza ◽  
T.Y. Yang ◽  
S. Brzev ◽  
K.J. Elwood ◽  
D.L. Anderson ◽  
...  

2018 ◽  
Vol 144 (3) ◽  
pp. 04018008 ◽  
Author(s):  
B. R. Robazza ◽  
S. Brzev ◽  
T. Y. Yang ◽  
K. J. Elwood ◽  
D. L. Anderson ◽  
...  

2021 ◽  
Vol 11 (10) ◽  
pp. 4421
Author(s):  
Zhiming Zhang ◽  
Fenglai Wang

In this study, four single-story reinforced masonry shear walls (RMSWs) (two prefabricated and two cast-in-place) under reversed cyclic loading were tested to evaluate their seismic performance. The aim of the study was to evaluate the shear behavior of RMSWs with flanges at the wall ends as well as the effect of construction method. The test results showed that all specimens had a similar failure mode with diagonal cracking. However, the crack distribution was strongly influenced by the construction method. The lateral capacity of the prefabricated walls was 12% and 27% higher than that of the corresponding cast-in-place walls with respect to the rectangular and T-shaped cross sections. The prefabricated walls showed better post-cracking performance than did the cast-in-place wall. The secant stiffness of all the walls decreased rapidly to approximately 63% of the initial stiffness when the first major diagonal crack was observed. The idealized equivalent elastic-plastic system showed that the prefabricated walls had a greater displacement ductility of 3.2–4.8 than that of the cast-in-place walls with a displacement ductility value of 2.3–2.7. This proved that the vertical joints in prefabricated RMSWs enhanced the seismic performance of walls in shear capacity and ductility. In addition, the equivalent viscous damping of the specimens ranged from 0.13 to 0.26 for prefabricated and cast-in-place walls, respectively.


2017 ◽  
Vol 16 (2) ◽  
pp. 859-887 ◽  
Author(s):  
Angelica Rosso ◽  
Lisandro A. Jiménez-Roa ◽  
João Pacheco de Almeida ◽  
Aydee Patricia Guerrero Zuniga ◽  
Carlos A. Blandón ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document