scholarly journals Water content and nature of solutes in shallow-mantle fluids from fluid inclusions

2012 ◽  
Vol 351-352 ◽  
pp. 70-83 ◽  
Author(s):  
Maria Luce Frezzotti ◽  
Simona Ferrando ◽  
Francesca Tecce ◽  
Daniele Castelli
Solid Earth ◽  
2017 ◽  
Vol 8 (5) ◽  
pp. 1025-1045 ◽  
Author(s):  
Andreas K. Kronenberg ◽  
Hasnor F. B. Hasnan ◽  
Caleb W. Holyoke III ◽  
Richard D. Law ◽  
Zhenxian Liu ◽  
...  

Abstract. Previous measurements of water in deformed quartzites using conventional Fourier transform infrared spectroscopy (FTIR) instruments have shown that water contents of larger grains vary from one grain to another. However, the non-equilibrium variations in water content between neighboring grains and within quartz grains cannot be interrogated further without greater measurement resolution, nor can water contents be measured in finely recrystallized grains without including absorption bands due to fluid inclusions, films, and secondary minerals at grain boundaries.Synchrotron infrared (IR) radiation coupled to a FTIR spectrometer has allowed us to distinguish and measure OH bands due to fluid inclusions, hydrogen point defects, and secondary hydrous mineral inclusions through an aperture of 10 µm for specimens > 40 µm thick. Doubly polished infrared (IR) plates can be prepared with thicknesses down to 4–8 µm, but measurement of small OH bands is currently limited by strong interference fringes for samples < 25 µm thick, precluding measurements of water within individual, finely recrystallized grains. By translating specimens under the 10 µm IR beam by steps of 10 to 50 µm, using a software-controlled x − y stage, spectra have been collected over specimen areas of nearly 4.5 mm2. This technique allowed us to separate and quantify broad OH bands due to fluid inclusions in quartz and OH bands due to micas and map their distributions in quartzites from the Moine Thrust (Scotland) and Main Central Thrust (Himalayas).Mylonitic quartzites deformed under greenschist facies conditions in the footwall to the Moine Thrust (MT) exhibit a large and variable 3400 cm−1 OH absorption band due to molecular water, and maps of water content corresponding to fluid inclusions show that inclusion densities correlate with deformation and recrystallization microstructures. Quartz grains of mylonitic orthogneisses and paragneisses deformed under amphibolite conditions in the hanging wall to the Main Central Thrust (MCT) exhibit smaller broad OH bands, and spectra are dominated by sharp bands at 3595 to 3379 cm−1 due to hydrogen point defects that appear to have uniform, equilibrium concentrations in the driest samples. The broad OH band at 3400 cm−1 in these rocks is much less common. The variable water concentrations of MT quartzites and lack of detectable water in highly sheared MCT mylonites challenge our understanding of quartz rheology. However, where water absorption bands can be detected and compared with deformation microstructures, OH concentration maps provide information on the histories of deformation and recovery, evidence for the introduction and loss of fluid inclusions, and water weakening processes.


2020 ◽  
Author(s):  
Stéphane Affolter ◽  
Dominik Fleitmann ◽  
Anamaria Häuselmann ◽  
Markus Leuenberger

&lt;p&gt;Speleothems are powerful archives able to gain relevant paleoclimate information on temperature, moisture source or rainfall. Specifically, there is a need for new proxy related to past moisture availability, which would allow reconstruction especially in Europe, where such records are lacking. Among speleothem-based records, quantitative estimation of the water content (hereafter WC) remains rare as it is generally a collateral result of more challenging analyses such as isotope determinations of fluid inclusions or noble gases. Using a recently developed method to analyse speleothem fluid inclusion water isotopes (Affolter et al., 2014), we obtained a record of more than 250 WC data covering the Younger Dryas and Holocene intervals with a decadal to multi-decadal resolution measured on two Swiss stalagmites from Milandre Cave, NW Switzerland. The crushing of samples in the measuring line resulted in a mean WC of 1.9 microlitre of water per gram of crushed calcite from both stalagmites. The comparison with other paleohumidity-related indicators from central Europe suggests that the WC is related to past moisture variability. In addition, trace elements strontium (Sr) and magnesium (Mg) measurements as proxies for the water residence time and growth rate respectively are ongoing at the Department of Environmental Sciences at the University of Basel, which will further help with the interpretation of the WC. New reconstruction of past moisture variability together with speleothem fluid inclusion temperature estimates (Affolter et al., 2019) would allow a better understanding of the central European climate variability during the Holocene.&lt;/p&gt;&lt;p&gt;Affolter, S., H&amp;#228;uselmann, A., Fleitmann, D., Edwards, R. L., Cheng, H., and Leuenberger, M.: Central Europe temperature constrained by speleothem fluid inclusion water isotopes over the past 14,000 years, Sci Adv, 5, eaav3809, 10.1126/sciadv.aav3809, 2019.&lt;/p&gt;&lt;p&gt;Affolter, S., Fleitmann, D., and Leuenberger, M.: New online method for water isotope analysis of speleothem fluid inclusions using laser absorption spectroscopy (WS-CRDS), Clim Past, 10, 1291-1304, DOI 10.5194/cp-10-1291-2014, 2014.&lt;/p&gt;


1996 ◽  
Vol 60 (17) ◽  
pp. 3229-3252 ◽  
Author(s):  
Jeffrey M. Rosenbaum ◽  
Alan Zindler ◽  
James L. Rubenstone

Author(s):  
Songquan Sun ◽  
Richard D. Leapman

Analyses of ultrathin cryosections are generally performed after freeze-drying because the presence of water renders the specimens highly susceptible to radiation damage. The water content of a subcellular compartment is an important quantity that must be known, for example, to convert the dry weight concentrations of ions to the physiologically more relevant molar concentrations. Water content can be determined indirectly from dark-field mass measurements provided that there is no differential shrinkage between compartments and that there exists a suitable internal standard. The potential advantage of a more direct method for measuring water has led us to explore the use of electron energy loss spectroscopy (EELS) for characterizing biological specimens in their frozen hydrated state.We have obtained preliminary EELS measurements from pure amorphous ice and from cryosectioned frozen protein solutions. The specimens were cryotransfered into a VG-HB501 field-emission STEM equipped with a 666 Gatan parallel-detection spectrometer and analyzed at approximately −160 C.


Author(s):  
George Guthrie ◽  
David Veblen

The nature of a geologic fluid can often be inferred from fluid-filled cavities (generally <100 μm in size) that are trapped during the growth of a mineral. A variety of techniques enables the fluids and daughter crystals (any solid precipitated from the trapped fluid) to be identified from cavities greater than a few micrometers. Many minerals, however, contain fluid inclusions smaller than a micrometer. Though inclusions this small are difficult or impossible to study by conventional techniques, they are ideally suited for study by analytical/ transmission electron microscopy (A/TEM) and electron diffraction. We have used this technique to study fluid inclusions and daughter crystals in diamond and feldspar.Inclusion-rich samples of diamond and feldspar were ion-thinned to electron transparency and examined with a Philips 420T electron microscope (120 keV) equipped with an EDAX beryllium-windowed energy dispersive spectrometer. Thin edges of the sample were perforated in areas that appeared in light microscopy to be populated densely with inclusions. In a few cases, the perforations were bound polygonal sides to which crystals (structurally and compositionally different from the host mineral) were attached (Figure 1).


Author(s):  
R.D. Leapman ◽  
S.Q. Sun ◽  
S-L. Shi ◽  
R.A. Buchanan ◽  
S.B. Andrews

Recent advances in rapid-freezing and cryosectioning techniques coupled with use of the quantitative signals available in the scanning transmission electron microscope (STEM) can provide us with new methods for determining the water distributions of subcellular compartments. The water content is an important physiological quantity that reflects how fluid and electrolytes are regulated in the cell; it is also required to convert dry weight concentrations of ions obtained from x-ray microanalysis into the more relevant molar ionic concentrations. Here we compare the information about water concentrations from both elastic (annular dark-field) and inelastic (electron energy loss) scattering measurements.In order to utilize the elastic signal it is first necessary to increase contrast by removing the water from the cryosection. After dehydration the tissue can be digitally imaged under low-dose conditions, in the same way that STEM mass mapping of macromolecules is performed. The resulting pixel intensities are then converted into dry mass fractions by using an internal standard, e.g., the mean intensity of the whole image may be taken as representative of the bulk water content of the tissue.


Sign in / Sign up

Export Citation Format

Share Document