Heat release rate of wooden cribs with water application for fire suppression

2018 ◽  
Vol 95 ◽  
pp. 170-179 ◽  
Author(s):  
Masaki Noaki ◽  
Michael A. Delichatsios ◽  
Jun-ichi Yamaguchi ◽  
Yoshifumi Ohmiya
2021 ◽  
Vol 15 (2) ◽  
Author(s):  
Wira Setiawan ◽  
Distyan Kotanjungan

Based on statistical data in recent years, there are still quite a number of ship accidents due to fires, including on passenger ships. The water mist system is a fire suppression system that allows it to be used in the engine room with the advantage that it can keep the heat production rate low during the extinguishing process and can be operated earlier than the CO2 system. The research is conducted by using fire dynamic simulator in the engine room of a 300 GT ferry ro-ro passenger to compare the heat release rate of fire without an extinguishing system, an existing CO2 system, and a water mist system. The result shows that the CO2 fire suppression system reduces the heat release rate more rapidly to the decay phase at 375 seconds while the water mist takes more than 900 seconds. However, the fully developed phase of the water mist suppression system occurs more quickly than CO2 because the sprinklers are activated shortly after a fire occurs. Unlike water mist, the CO2 system is activated at 60 seconds so that the pre-combustion, growth, flashover, and fully developed phases are at the same HRR and time as the natural one.


2008 ◽  
Vol 18 (2) ◽  
pp. 111-124 ◽  
Author(s):  
C. Chen ◽  
L. Qu ◽  
Y. X. Yang ◽  
G. Q. Kang ◽  
W. K. Chow

2021 ◽  
Vol 11 (7) ◽  
pp. 3247
Author(s):  
Dong Hwan Kim ◽  
Chi Young Lee ◽  
Chang Bo Oh

In this study, the effects of discharge area and atomizing gas type in a twin-fluid atomizer on heptane pool fire-extinguishing performance were investigated under the heat release rate conditions of 1.17 and 5.23 kW in an enclosed chamber. Large and small full cone twin-fluid atomizers were prepared. Nitrogen and air were used as atomizing gases. With respect to the droplet size of water mist, as the water and air flow rates decreased and increased, respectively, the Sauter mean diameter (SMD) of the water mist decreased. The SMD of large and small atomizers were in the range of approximately 12–60 and 12–49 μm, respectively. With respect to the discharge area effect, the small atomizer exhibited a shorter extinguishing time, lower peak surface temperature, and higher minimum oxygen concentration than the large atomizer. Furthermore, it was observed that the effect of the discharge area on fire-extinguishing performance is dominant under certain flow rate conditions. With respect to the atomizing gas type effect, nitrogen and air appeared to exhibit nearly similar extinguishing times, peak surface temperatures, and minimum oxygen concentrations under most flow rate conditions. Based on the present and previous studies, it was revealed that the effect of atomizing gas type on fire-extinguishing performance is dependent on the relative positions of the discharged flow and fire source.


Fuel ◽  
2021 ◽  
Vol 288 ◽  
pp. 119656
Author(s):  
Robbert Willems ◽  
Frank Willems ◽  
Niels Deen ◽  
Bart Somers

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1622
Author(s):  
Daniel Romeo Kamta Legue ◽  
Zacharie Merlin Ayissi ◽  
Mahamat Hassane Babikir ◽  
Marcel Obounou ◽  
Henri Paul Ekobena Fouda

This study presents an experimental investigation and thermodynamic 0D modeling of the combustion of a compression-ignition engine, fueled by an alternative fuel based on neem biodiesel (B100) as well as conventional diesel (D100). The study highlights the effects of the engine load at 50%, 75% and 100% and the influence of the heat loss models proposed by Woschni, Eichelberg and Hohenberg on the variation in the cylinder pressure. The study shows that the heat loss through the cylinder wall is more pronounced during diffusion combustion regardless of the nature of the fuels tested and the load range required. The cylinder pressures when using B100 estimated at 89 bars are relatively higher than when using D100, about 3.3% greater under the same experimental conditions. It is also observed that the problem of the high pressure associated with the use of biodiesels in engines can be solved by optimizing the ignition delay. The net heat release rate remains roughly the same when using D100 and B100 at 100% load. At low loads, the D100 heat release rate is higher than B100. The investigation shows how wall heat losses are more pronounced in the diffusion combustion phase, relative to the premix phase, by presenting variations in the curves.


Sign in / Sign up

Export Citation Format

Share Document